Journals / Anestezi Dergisi / 2014 / Cilt: 22 - Sayı: 4

MIXED VENOUS OXYGEN SATURATION AND CLINICAL SIGNIFICANCE

MİKS VENÖZ OKSİJEN SATURASYONU VE KLİNİK ÖNEMİ

Pages
181–185
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In this review, it is aimed to have an updated look at the clinical significance of mixed venous oxygen saturation.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Mixed venous oxygen saturation known as global index of tissue oxygenation, is an integral part of hemodynamic monitoring for especially follow-up of critically-ill patients.
📊
Key Findings & Data:Although it is needed to insert a pulmonary artery catheter to measure mixed venous oxygen saturation, and it is a major obstacle for the common usage of this hemodynamic parameter, currently it is used by multiple health care centres because of its ability to interfere instantly with the measured tissue oxygenation levels of unstable patients in operation room or intensive care units.
💡
Conclusion & Impact:In this review, it is aimed to have an updated look at the clinical significance of mixed venous oxygen saturation.
🔬Design:Review & Systematic Survey
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Mixed venous oxygen saturation known as global index of tissue oxygenation, is an integral part of hemodynamic monitoring for especially follow-up of critically-ill patients. Although it is needed to insert a pulmonary artery catheter to measure mixed venous oxygen saturation, and it is a major obstacle for the common usage of this hemodynamic parameter, currently it is used by multiple health care centres because of its ability to interfere instantly with the measured tissue oxygenation levels of unstable patients in operation room or intensive care units. In this review, it is aimed to have an updated look at the clinical significance of mixed venous oxygen saturation.

Özet

Doku oksijenasyonunun global göstergesi olarak kabul edilen miks venöz oksijen saturasyonu özellikle kritik hasta takibinde hemodinamik monitorizasyonun ayrılmaz bir parçasıdır. Miks venöz oksijen saturasyonunun ölçümü için pulmoner arter kateterine gereksinim duyulması, sözü edilen hemodinamik parametrenin yaygın kullanılmasına büyük bir engel oluştursa da, hemodinamik olarak stabil olmayan hastaların ameliyat sırasında veya yoğun bakım ünitelerinde o anki doku oksijenizasyon düzeyinin saptanarak anlık müdahale olanağı tanıması nedeniyle halen birçok merkez tarafından kullanılmaktadır. Bu derlemede miks venöz oksijen saturasyonunun klinik önemine güncel bir bakış amaçlanmıştır.

🔖

Cite This Article

KIR, B., BİLGİLİ, B., CİNEL, İ. (2014). MIXED VENOUS OXYGEN SATURATION AND CLINICAL SIGNIFICANCE. Anestezi Dergisi, Cilt: 22 - Sayı: 4, 181–185. https://ajindex.com/articles/355430

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Winters ME, McCurdy MT, Zilberstein J. Monitoring the critically ill Emergency Department patient. Emerg Med Clin N Am 2008; 26: 741-757.
  2. Nebout S, Pirracchio R, Should we monitor ScVO2 in critically ill patients? Cardiol Res Pract 2012; 2012: 370697. van Beest PA, Hofstra JJ, Schultz MJ, Boerma EC, Spronk PE, Kuiper MA. The incidence of low venous oxygen saturation on admission to the intensive care unit: a multi-center observational study in The Netherlands, Crit Care 2008; 12: R33. Pinsky MR, Payen D. Functional Hemodynamic monitoring. Crit Care 2005; 9: 566-572.
  3. Casserly B, Read R, Levy MM. Hemodynamic monitoring in sepsis Crit Care Nurs Clin N Am 2011; 23: 149-169.
  4. Van Beest P, Wietasch G, Scheeren T, Spronk P, Kuiper M. Clinical review: use of venous oxygen saturations as a goal - a yet unfinished puzzle. Crit Care 2011; 15: 232. Boldt J. Clinical review: Hemodynamic monitoring in the intensive care unit Crit Care 2002; 6: 52-59. Ranucci M. Which cardiac surgical patients can benefit from placement of a pulmonary artery catheter? Crit Care 2006; 10: S6. Velissaris D, Pierrakos C, Scolletta S, De Backer D, Vincent JL. High mix venous oxygen saturation levels do not exclude fluid responsiveness in critically ill septic patients. Crit Care 2011; 15: R177. Edwards JD, Shoemaker WC, Vincent JL Oxygen Transport: Principles and Practice, Chapter 1 Overview: Evolution of the concept from Fick to the present day. p.1-14.
  5. Chawla SL, Zia H, Gutierrez G et al. Lack of equivalence between central and mixed venous oxygen saturation Chest 2004; 126: 1891-1896.
  6. Maddirala S, Khan A. Optimizing hemodynamic support in septic shock using central and mixed venous saturation. Crit Care Clin 2010; 26: 323-333.
  7. Jones A, Puskarich M. Sepsis –Induced tissue hypoperfusion. Crit Care Nurs Clin N Am 2011; 23: 115-125.
  8. Allashemi JA, Cecconi M, Hofer C. Cardiac output monitoring: an integrated perspective Crit Care 2011; 15: 214. Payen D, Gayat E. Which general intensive care unit patients can benefit from placement of the pulmonary artery catheter? Crit Care 2006; 10: S7. Maddirala S, Khan A. Optimizing hemodynamic support in septic shock using central and mixed venous oxygen saturation. Crit Care Clin 2010; 26: 323-333.
  9. Sumimoto T, Takayam Y, Iwasaka T, et al. Mixed venous oxygen saturation as a guide to tissue oxygenation and prognosis in patients with acute myocardial infarction. Am Heart J 1991; 122: 27-33.
  10. Holm J., Hakanson E, Vanky F, Svedjeholm R. Mixed venous oxygen sat