Journals / Anestezi Dergisi / 2020 / Cilt: 28 - Sayı: 4

Kardiyak Cerrahide Santral Venöz Laktat Ölçümü Arteryel Laktat Ölçümünün Yerini Tutabilir mi?

Does Central Venous Lactate Measurement Replace Arterial Lactate Measurement in Cardiac Surgery?

Pages
261–266
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Sonuç: Her ne kadar laktat ölçümünün arteryel kandan örneklenmesi “altın standart” olarak kabul edilse de, on-pump kalp cerrahisi hastalarında santral venöz kandan örnekleme de kabul edilebilir bir alternatif olabilir.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Amaç: Doku perfüzyonunun yeterliliği için önemli bilgi veren laktat düzeyleri, genellikle kan gazlarıyla birlikte kan gazı cihazları tarafından ölçülür.
📊
Key Findings & Data:Her ne kadar arteriyel kan, laktat ölçümü için “altın standart” olsa da, arteryel ve venöz laktat ölçümlerinin birbirinin yerine kullanılabilmesi, venöz kan gazı değerlendirmesinin tercih edildiği durumlarda, sık kan örneklemesinin neden olabileceği artmış maliyet ve iatrojenik anemiye engel olabilir.
💡
Conclusion & Impact:Sonuç: Her ne kadar laktat ölçümünün arteryel kandan örneklenmesi “altın standart” olarak kabul edilse de, on-pump kalp cerrahisi hastalarında santral venöz kandan örnekleme de kabul edilebilir bir alternatif olabilir.
🔬Design:Survey & Empirical Study
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Amaç: Doku perfüzyonunun yeterliliği için önemli bilgi veren laktat düzeyleri, genellikle kan gazlarıyla birlikte kan gazı cihazları tarafından ölçülür. Her ne kadar arteriyel kan, laktat ölçümü için “altın standart” olsa da, arteryel ve venöz laktat ölçümlerinin birbirinin yerine kullanılabilmesi, venöz kan gazı değerlendirmesinin tercih edildiği durumlarda, sık kan örneklemesinin neden olabileceği artmış maliyet ve iatrojenik anemiye engel olabilir. Bu çalışmada amacımız; on-pump kardiyak cerrahide arteryel (AL) ve santral venöz laktat (CVL) değerleri arasındaki korelasyon ve uyumu incelemektir. Yöntem: Anestezik yönetim dahilinde, T1: anestezi indüksiyonu sonrası, T2: kros klemp sırasında ve T3: cilt kapatılırken olmak üzere üç aşamada eşzamanlı olarak arteryel ve venöz kan örnekleri olan yetişkin hastalar, bu retrospektif gözlemsel çalışmaya dahil edildi. CVL ve AL konsantrasyonları, T1, T2 ve T3 aşamalarındaki kan gazı analizinden elde edildi. Spearman Rho and Bland-Altman Testleri, AL ve CVL arasındaki sırasıyla korelasyon ve uyumu değerlendirmek için kullanıldı. Bulgular: Toplamda 122 uygun hastadan 366 çift kan örneği elde edildi. 95% güven aralıkları sırasıyla; T1’de -0.07 ve -0.00, T2’de 0.30 ve -0.10 ve T3’de -0.16 ve -0.03’tü. 95% CI ise T1’de 0.86 ve 0.93 (r=0.90 ve p<0.0001); T2’de 0.95 ve 0.97 (r=0.96 ve p<0.0001) ve T3’de 0.92 to 0.96 (r=0.94 and p<.0001) olarak saptandı. Sonuç: Her ne kadar laktat ölçümünün arteryel kandan örneklenmesi “altın standart” olarak kabul edilse de, on-pump kalp cerrahisi hastalarında santral venöz kandan örnekleme de kabul edilebilir bir alternatif olabilir.

Özet

Objective: Lactate levels, which provide valuable information about the adequacy of tissue perfusion, are usually measured by blood gas analyzers simultaneously with blood gases. Althougharterial blood is the “gold standard” for measurement of lactate, the interchangeable use of arterial and venous lactate measurements can avoid increased costs and iatrogenic anemia resultingfrom frequent blood sampling when evaluation of venous blood gas samples are preferred. In thisstudy; we aimed to examine the correlation and agreement between the arterial lactate (AL) andcentral venous lactate (CVL) values in patients undergoing on-pump cardiac surgery.Method: Adult patients who had both arterial and central venous blood gas sampling simultaneously in three stages (T1: after anesthesia induction, T2: during cross- clamping, T3: during skinclosure) of operation as part of anesthetic management were eligible for inclusion in this retrospective study. CVL and AL concentrations were estimated during blood gas analysis at stages T1,T2 and T3. Spearman Rho and Bland-Altman Tests were used to assess correlation and agreementbetween AL and CVL measurements, respectively.Results: Totally 366 pairs of blood samples were obtained from 122 eligible patients. The 95%limits of agreement were -0.07 to -0.00 at T1; 0.30 to -0.10 at T2 and -0.16 to -0.03 at T3. The95% Cls were detected 0.86 to 0.93 (r=0.90 and p<0.0001) at T1;0.95 to 0.97 at T2 (r=0.96 andp<0.0001) and 0.92 to 0.96 (r=0.94 and p<0.0001) at T3.Conclusion: Although sampling from arterial lactate can be considered as the “gold standard” forlactate measurement, sampling from central venous blood is an acceptable alternative for lactatemeasurement in on-pump cardiac surgery patients

🔖

Cite This Article

TEZCAN, B., MUNGAN, İ., ŞAYLAN, A., ADEMOĞLU, D., SARI, S., DİCLE, Ç. B., AYTEKİN, B., ÖZGÖK, A., YAZICIOĞLU, H. (2020). Kardiyak Cerrahide Santral Venöz Laktat Ölçümü Arteryel Laktat Ölçümünün Yerini Tutabilir mi?. Anestezi Dergisi, Cilt: 28 - Sayı: 4, 261–266. https://ajindex.com/articles/355154

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Bloom B, Pott J, Freund Y, Grundlingh J, Harris T. The agreement between abnormal venous lactate and arterial lactate in the ED: a retrospective chart review. Am J Emerg Med. 2014;32:596-600.
  2. Higgins C. Lactate measurement: arterial versus venous blood sampling. Online Referencing acutecaretesting.org Jan 2017
  3. Swan H, Sanchez M, Tyndall CM, Koch C. Quality control of perfusion: monitoring venous blood oxygen tension to prevent hypoxic acidosis. J Thorac Cardiovasc Surg. 1990;99:868-72.
  4. Alves RL, Aragão e Silva AL, Kraychete NC, Campos GO, Martins Mde J, Módolo NS. Intraoperative lactate levels and postoperative complications of pediatric cardiac surgery. Paediatr Anaesth. 2012;22:812-17.
  5. Svenmarker S, Häggmark S, Ostman M. What is a normal lactate level during cardiopulmonary bypass? Scand Cardiovasc J. 2006;40:305-11.
  6. Sun J, Chen H, Zheng J, Mao B, Zhu S, Feng J. Continuous blood pressure monitoring via non-invasive radial artery applanation tonometry and invasive arterial catheter demonstrates good agreement in patients undergoing colon carcinoma surgery. J Clin Monit Comput. 2017;31:1189-95.
  7. Lin WQ, Wu HH, Su CS, et al. Comparison of Continuous Noninvasive Blood Pressure Monitoring by TL-300 With Standard Invasive Blood Pressure Measurement in Patients Undergoing Elective Neurosurgery. J Neurosurg Anesthesiol. 2017;29:1-7.
  8. Murdoch IA, Turner C, Dalton RN. Arterial or mixed venous lactate measurement in critically ill children. Is there a difference? Acta Paediatr. 1994;83:412-3.
  9. Middleton P, Kelly A-M, Brown J, Robertson M. Agreement between arterial and central venous values for pH, bicarbonate, base excess, and lactate. Emerg Med J. 2006;23:622-4.
  10. Lavery RF, Livingston DH, Tortella BJ, Sambol JT, Slomovitz BM, Siegel JH. The utility of venous lactate to triage injured patients in the trauma center. J Am Coll Surg. 2000;190:656-64.
  11. Réminiac F, Saint-Etienne C, Runge I, et al. Are central venous lactate and arterial lactate interchangeable? A human retrospective study. Anesth Analg. 2012;115:605-10. https://doi.org/10.121