Journals / Acta Orthopaedica et Traumatologica Turcica / 2017 / Cilt: 51 - Sayı: 5

Dynamic hip system blade versus cannulated compression screw for the treatment of femoral neck fractures: A retrospective study

Pages
381–387
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

However, the DHS-BLADE has advantages over cannulated compression screws for preventing femoral neck shortening, screw migration, and cut-out

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: The aim of this study was to compare clinical outcomes of patients with femoral neck fractures treated with the dynamic hip system blade (DHS-BLADE) or cannulated compression screws.
📊
Key Findings & Data:Methods: Eighty-six patients with femoral neck fractures were treated by closed reduction internal fixation with a DHS-BLADE (n = 42; 18 males and 24 females; mean age: 56.3 years (37e87)) or cannulated compression screws (n = 44; 20 males and 24 females; mean age: 53.8 years (26e83)) between March 2011 and August 2013.
💡
Conclusion & Impact:However, the DHS-BLADE has advantages over cannulated compression screws for preventing femoral neck shortening, screw migration, and cut-out
🔬Design:Research Article
📍Scope:2011 Verileri
⚙️Variables:Domain Parameters

Abstract

Objective: The aim of this study was to compare clinical outcomes of patients with femoral neck fractures treated with the dynamic hip system blade (DHS-BLADE) or cannulated compression screws. Methods: Eighty-six patients with femoral neck fractures were treated by closed reduction internal fixation with a DHS-BLADE (n = 42; 18 males and 24 females; mean age: 56.3 years (37e87)) or cannulated compression screws (n = 44; 20 males and 24 females; mean age: 53.8 years (26e83)) between March 2011 and August 2013. The groups were compared with Harris hip score, operation time, surgical blood loss, incision size, hospital stay, and related complications. Results: The average follow-up time was 27 months (range, 24e36 months). There was no significant difference for the operation time, incision size, hospital stay, and Harris hip score between the groups. Also, no statistically significant differences in the rates of nonunion (4.5% vs. 0) and avascular necrosis of the femoral head (9.1% vs. 7.1%) were observed. However, the screw group experienced significantly less surgical blood loss (32.4 ± 24.7 ml) than the blade group (87.2 ± 46.6 ml; P = 0.041). The incidence of femoral neck shortening above 10 mm in the screw group was significantly higher than that in the blade group (15.9% vs. 2.4%, P = 0.031). The blade group had a significantly lower incidence of screw migration than the screw group (4.8% vs. 22.7%, P = 0.016). Conclusion: The DHS-BLADE and cannulated compression screws might be equally effective in terms of postoperative fracture union. However, the DHS-BLADE has advantages over cannulated compression screws for preventing femoral neck shortening, screw migration, and cut-out

🔖

Cite This Article

CHEN, C., YU, L., TANG, X., LİU, M., SUN, L., LİU, C., ZHANG, Z., Lİ, C. (2017). Dynamic hip system blade versus cannulated compression screw for the treatment of femoral neck fractures: A retrospective study. Acta Orthopaedica et Traumatologica Turcica, Cilt: 51 - Sayı: 5, 381–387. https://ajindex.com/articles/353957

References (15)

  1. Broderick JM, Bruce-Brand R, Stanley E, et al. Osteoporotic hip fractures: the burden of fixation failure. Sci World J. 2013;2013:515197
  2. Wilk R, Skrzypek M, Kowalska M, et al. Standardized incidence and trend of osteoporotic hip fracture in Polish women and men: a nine year observation. Maturitas. 2014;77:59e63
  3. Parker MJ. Results of internal fixation of Pauwels type-3 vertical femoral neck fractures. J Bone Jt Surg Am. 2009;91:490e491
  4. Sommers MB, Roth C, Hall H, et al. A laboratory model to evaluate cutout resistance of implants for pertrochanteric fracture fixation. J Orthop Trauma. 2004;18:361e368
  5. Simmermacher RK, Ljungqvist J, Bail H, et al. The new proximal femoral nail antirotation (PFNA) in daily practice: results of a multicentre clinical study. Injury. 2008;39:932e939
  6. Strauss E, Frank J, Lee J, et al. Helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: a biomechanical evaluation. Injury. 2006;37:984e989
  7. Windolf M, Muths R, Braunstein V, et al. Quantification of cancellous bonecompaction due to DHS Blade insertion and influence upon cut-out resistance. Clin Biomech (Bristol, Avon). 2009;24:53e58
  8. Windolf M, Braunstein V, Dutoit C, et al. Is a helical shaped implant a superior alternative to the Dynamic Hip Screw for unstable femoral neck fractures? A biomechanical investigation. Clin Biomech (Bristol, Avon). 2009;24:59e64
  9. Leung F, Gudushauri P, Yuen G, et al. Dynamic hip screw blade fixation for intertrochanteric hip fractures. J Orthop Surg. 2013:132e133
  10. Zhao WB, Liu L. Effect of dynamic hip system blade on the treatment of femoral neck fractures in elderly patients with osteoporosis. Chin J Traumatol. 2014;17: 275e278
  11. Neilipovitz DT, Murto K, Hall L, Barrowman NJ, Splinter WM. A randomized trial of tranexamic acid to reduce blood transfusion for scoliosis surgery. Anesth Analg. 2001;93:82e87
  12. Wong J, Hossam E, Suntheralingam Y, Rampersaud R, Chung F. Tranexamic acid reduces blood loss and transfusion in adult patients having spinal fusion surgery. Can J Anesth. 2006;53(suppl 1):26385
  13. Boraiah S, Paul O, Hammoud S, Gardner MJ, Helfet DL, Lorich DG. Predictable healing of femoral neck fractures treated with intraoperative compression and length-stable implants. J Trauma. 2010;69:142e147
  14. Zlowodzki M, Jonsson A, Paulke R. Shortening after femoral neck fracture € fixation: is there a solution? Clin Orthop Relat Res. 2007;461:213e218
  15. Harris WH. Tr