Journals / Acta Orthopaedica et Traumatologica Turcica / 2013 / Cilt: 47 - Sayı: 1

Bilgisayarla navigasyonun total diz artroplastisinde komponent dizilimine etkisi

The effect of computerized navigation on component alignment in total knee arthroplasty

Pages
8–13
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: Computer navigation in TKA appears to be a reliable system which facilitates implant positioning and component alignment.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: The aim of this retrospective cross-sectional study was to evaluate the effect of computer-assisted total knee arthroplasty (TKA) on component alignment.
📊
Key Findings & Data:Methods: The radiographs of 20 patients who underwent computer-assisted TKA within a two-year period were analyzed with respect to the mechanical femorotibial, mechanical femoral, mechanical tibial angles (mFTA, mFA and mTA, respectively) and the tibial slope (s).
💡
Conclusion & Impact:Conclusion: Computer navigation in TKA appears to be a reliable system which facilitates implant positioning and component alignment.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Objective: The aim of this retrospective cross-sectional study was to evaluate the effect of computer-assisted total knee arthroplasty (TKA) on component alignment. Methods: The radiographs of 20 patients who underwent computer-assisted TKA within a two-year period were analyzed with respect to the mechanical femorotibial, mechanical femoral, mechanical tibial angles (mFTA, mFA and mTA, respectively) and the tibial slope (s). Results: The mean postoperative mFTA (179.7°) was significantly improved when compared to the preoperative value (175.45°) (p=0.012). The mean postoperative mFA was significantly reduced (p=0.035) in comparison with the preoperative mean (89.1° and 90.6°, respectively). The mean postoperative mTA was exactly 90.0°, while the preoperative mean was significantly lower (87.7°; p=0.003). Mean tourniquet time during TKA was 109.5 minutes. Conclusion: Computer navigation in TKA appears to be a reliable system which facilitates implant positioning and component alignment.

Özet

Amaç: Bu retrospektif, kesitsel çalışmada bilgisayar yardımlı total diz artroplastisinin (TDA) komponent dizilimine etkisinin incelenmesi amaçlandı. Çalışma planı: İki yıllık süreç içinde bilgisayar yardımlı TDA uygulanan 20 hastanın radyografileri mekanik femorotibial, mekanik femoral, mekanik tibial açılar (sırasıyla, mFTA, mFA ve mTA) ve tibial eğim (s) açısından incelendi. Bulgular: Ameliyat sonrası ortalama mFTA (179.7°) ameliyat öncesi değerle karşılaştırıldığında (175.45°) anlamlı derecede düşüş gösterdi (p=0.012). Ameliyat sonrası ortalama mFA da (89.1°) ameliyat öncesi değere (90.6°) göre anlamlı derecede azalmıştı (p=0.035). Ameliyat sonrası ortalama mTA tam olarak 90.0° kaydedilirken, ameliyat öncesi değeri (87.7°) anlamlı derecede daha düşüktü (p=0.003). TDA sırasında ortalama turnike süresi 109.5 dakika olarak ölçüldü. Çıkarımlar: Bilgisayarla navigasyon TDAda implant konumlandırması ve komponent diziliminin iyileştirilmesi için güvenilir bir sistemdir.

🔖

Cite This Article

SOARES, L. F. M., NUNES, T. A., ANDRADE, M. A. P. D., NEYRET, P., BADET, R. (2013). Bilgisayarla navigasyonun total diz artroplastisinde komponent dizilimine etkisi. Acta Orthopaedica et Traumatologica Turcica, Cilt: 47 - Sayı: 1, 8–13. https://ajindex.com/articles/353659

References (7)

  1. Stindel E, Gil D, Briard JL, Merloz P, Dubrana F, Lefevre C. Evaluation de la précision et de la reproductibilité de l’al- gorithme « surgetic » de détection du centre hanche. In: Troccaz J, Merloz P, editors. Surgetica 2002. Gestes médi- co-chirurgicaux assistés par ordinateur: outils et applications [Computer-aided medical interventions: tools and applica- tions]. Paris: Sauramps Médical; 2002. p. 48
  2. Aglietti P, Buzzi R. Posterior stabilized total-condylar knee replacement. Three to eight years’ follow-up of 85 knees. J Bone Joint Surg Br 1988;70:211
  3. Hansen AD, Rand JA. Instructional Course Lectures, The American Academy of Orthopaedic Surgeons - Evaluation and treatment of infection at the site of a total hip or knee arthroplasty. J Bone Joint Surg Am 1998;80:910-22
  4. Taylor RH, Lavallée S, Burdea GC, Mösges R. Computer- integrated surgery. Technology and clinical applications. 1996. Clin Orthop Relat Res 1998;(354):5-7
  5. Saragaglia D, Picard F, Chaussard C, Montbarbon E, Leitner F, Cinquin P. Computer-assisted knee arthroplasty: comparison with a conventional procedure. Results of 50 cases in a prospective randomized study. [Article in French] Rev Chir Orthop Reparatrice Appar Mot 2001;87:18-28
  6. Townley CD. The anatomic total knee: instrumentation and alignment technique. In: Dorr LD, editor. The Knee: Papers of the First Scientific Meeting of the Knee Society. Baltimore: University Press; 1985. p. 39-54. Nodé-Langlois L. Pre- and postoperative dimensional analysis of the angular deviations of the axes of the lower limb. [Doctorate thesis in French]. Paris: L’École Nationale Supérieure d’Arts et Métiers; 2003. Jenny JY, Boeri C. Computer-assisted implantation of a total knee arthroplasty: a case-controlled study in comparison with classical instrumentation. [Article in French] Rev Chir Orthop Reparatrice Appar Mot 2001;87:645-52. Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A. Positioning of total knee arthroplasty with and without nav- igation support. A prospective, randomised study. J Bone Joint Br 2003;85:830-5. Nizard RS, Groupe Guépar. System of computer-assisted surgery for total knee replacement. Theoretical justification. Current status. [Article in French] Paris: Cahier d’Enseignement de La Societé Française de Chirurgie Orthopédique et Traumatologique; 2002. p
  7. Selmi T A, Zanone X, Neyret P. Knee prosthesis in malu- nion. [Article in French] Chirurgie prothétique du genou. Paris: Sauramps Médical; 1999. p. 221-39. B