Journals / Acta Orthopaedica et Traumatologica Turcica / 2016 / Cilt: 50 - Sayı: 2

A new complication in volar locking plating of the distal radius: longitudinal fractures of the near cortex

Pages
147–152
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Additional divergent configuration may promote this effect and crack the cortex

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: The purpose of this study was to document a new complication in volar locking plating of the distal radius.Methods: Between January 2007 and January 2014, 223 patients were identified from the department's surgical database with retrospective chart and radiographic review.
📊
Key Findings & Data:Sixty-eight patients were over 60 years of age.
💡
Conclusion & Impact:Additional divergent configuration may promote this effect and crack the cortex
🔬Design:Review & Systematic Survey
📍Scope:2007 Verileri
⚙️Variables:Domain Parameters

Abstract

Objective: The purpose of this study was to document a new complication in volar locking plating of the distal radius.Methods: Between January 2007 and January 2014, 223 patients were identified from the department's surgical database with retrospective chart and radiographic review. Sixty-eight patients were over 60 years of age. All fractures were operated with Acu-Loc® (Acumed, Hillsboro, OR, USA) wrist volar locking plating systems. Longitudinal fracture lines (LFL) beneath volar plate-extending proximal shafts were documented. Correlations between age groups and LFLs were investigated. Radiographs with LFLs were assessed at final follow-up for the following parameters: volar tilt, radial inclination and radial length.Results: Twenty-eight of 68 patients over age of 60 years had LFLs. Correlation was significant for age groups (p<0.05). The effect of these fracture lines on radiographic parameters was not significant (p>0.05).Conclusion: Surgeons should be aware of the complications that may occur with volar locking plates. Understanding of potential complications and their results are important. As a result of aging, thinning, and weakening, the near cortex may become more brittle. When the plate is reduced on the bone with a nonlocking screw, the conical head of diaphyseal locking screws can extend over plate thickness and penetrate the near cortex, acting as a screwing wedge. Additional divergent configuration may promote this effect and crack the cortex

🔖

Cite This Article

SÜGÜN, T. S., GÜRBÜZ, Y., ÖZAKSAR, K., TOROS, T., BAL, E., KAYALAR, M. (2016). A new complication in volar locking plating of the distal radius: longitudinal fractures of the near cortex. Acta Orthopaedica et Traumatologica Turcica, Cilt: 50 - Sayı: 2, 147–152. https://ajindex.com/articles/353545

References (10)

  1. McKay SD, MacDermid JC, Roth JH, Richards RS. As- sessment of complications of distal radius fractures and development of a complication checklist. J Hand Surg Am 2001;26:916-22.
  2. Singer BR, McLauchlan GJ, Robinson CM, Christie J. Epidemiology of fractures in 15,000 adults: the influence of age and gender. J Bone Joint Surg Br 1998;80:243-8.
  3. Chung KC, Watt AJ, Kotsis SV, Margaliot Z, Haase SC, Kim HM. Treatment of unstable distal radial fractures with the volar locking plating system. J Bone Joint Surg Am 2006;88:2687-94.
  4. Wright TW, Horodyski M, Smith DW. Functional out- come of unstable distal radius fractures: ORIF with a volar fixed-angle tine plate versus external fixation. J Hand Surg Am 2005;30:289-99.
  5. Högel F, Mair S, Eberle S, Weninger P, von Oldenburg G, Augat P. Distal radius fracture fixation with volar locking plates and additional bone augmentation in osteoporotic bone: a biomechanical study in a cadaveric model. Arch Orthop Trauma Surg 2013;133:51-7. Bentohami A, de Burlet K, de Korte N, van den Bekerom MP, Goslings JC, Schep NW. Complications following vo- lar locking plate fixation for distal radial fractures: a sys- tematic review. J Hand Surg Eur Vol 2014;39:745-54.
  6. Toros T, Sügün TS, Özaksar K. Complications of distal radius locking plates. Injury 2013;44:336-9. http://www.rcsed.ac.uk/fellows/lvanrensburg/classifica- tion/surgtech/acumed/manuals/Acumed-Acu-Loc-2_ Brochure.pdf. Cooper EO, Segalman KA, Parks BG, Sharma KM, Nguy- en A. Biomechanical stability of a volar locking-screw plate versus fragment-specific fixation in a distal radius fracture model. Am J Orthop (Belle Mead NJ) 2007;36:E46-9. Willis AA, Kutsumi K, Zobitz ME, Cooney WP 3rd. In- ternal fixation of dorsally displaced fractures of the distal part of the radius. A biomechanical analysis of volar plate fracture stability. J Bone Joint Surg Am 2006;88:2411-7.
  7. Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 2007;21:316-22.
  8. Jakob M, Rikli DA, Regazzoni P. Fractures of the distal radius treated by internal fixation and early function. A prospective study of 73 consecutive patients. J Bone Joint Surg Br 2000;82:340-4.
  9. Rozental TD, Blazar PE. Functional outcome and com- plications after volar plating for dorsally displaced, un- stable fractures of the distal radius. J Hand Surg Am 2006;31:359-65.
  10. Sügün TS, Karabay N, Gürbüz Y, Ozaksar K, Toros