Journals / Acta Orthopaedica et Traumatologica Turcica / 2018 / Cilt: 52 - Sayı: 4

Distal medial tibial locking plate for fixation of extraarticular distal humeral fractures; an alternative choice for fixation

Pages
294–298
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

There were nodifferences in the comparison of grasp and pinch grip of patients with uninvolved extremity (p > 0.05).Conclusions: In distal humeral extra-articular fractures, use of distal medial tibia plate has advantagessuch as providing high rates for union, low rates for complication, and early return to work with earlyrehabilitation, therefore it may be considered a fixation choice that can be used for distal humeral extraarticularfractures

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: The aim of this study was to describe an alternative fixation method for distal humeral extraarticularfractures through posterior approach using distal tibia anatomic locking plate; and to evaluatethe patient's functional outcome and union condition.Methods: Eighteen patients (11 men and 7 women; average age of 37.0 ± 17.3 years (range: 18e73 years))with a distal humeral extra-articular fracture who were treated with distal tibial medial locking platewere included into the study.
📊
Key Findings & Data:The mean follow up time was 36.2 ± 16.7 (12e57) months.
💡
Conclusion & Impact:There were nodifferences in the comparison of grasp and pinch grip of patients with uninvolved extremity (p > 0.05).Conclusions: In distal humeral extra-articular fractures, use of distal medial tibia plate has advantagessuch as providing high rates for union, low rates for complication, and early return to work with earlyrehabilitation, therefore it may be considered a fixation choice that can be used for distal humeral extraarticularfractures
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Objective: The aim of this study was to describe an alternative fixation method for distal humeral extraarticularfractures through posterior approach using distal tibia anatomic locking plate; and to evaluatethe patient's functional outcome and union condition.Methods: Eighteen patients (11 men and 7 women; average age of 37.0 ± 17.3 years (range: 18e73 years))with a distal humeral extra-articular fracture who were treated with distal tibial medial locking platewere included into the study. The mean follow up time was 36.2 ± 16.7 (12e57) months. Functionalresults were evaluated with perception of pain, range of joint motion, grasp and pinch strengths.Results: Union was achieved in 17 of 18 patients. Only one patient had non-union due to infection andunderwent debridement. The mean time for union was 7.8 ± 5.9 months (2e20). Patient perception ofpain was X ¼ 1.88 ± 2.50 and X ¼ 4.55 ± 2.68, respectively, at rest and activity. The active ranges of jointmotion were adequate for functional use. General functional state of affected extremity (DASH-T) wasperfect (X ¼ 27.14 ± 25.66), the performance of elbow joint was good (X ¼ 84.44 ± 11.57). There were nodifferences in the comparison of grasp and pinch grip of patients with uninvolved extremity (p > 0.05).Conclusions: In distal humeral extra-articular fractures, use of distal medial tibia plate has advantagessuch as providing high rates for union, low rates for complication, and early return to work with earlyrehabilitation, therefore it may be considered a fixation choice that can be used for distal humeral extraarticularfractures

🔖

Cite This Article

YÖRÜKOĞLU, A. Ç., DEMİRKAN, A. F., BÜKER, N. (2018). Distal medial tibial locking plate for fixation of extraarticular distal humeral fractures; an alternative choice for fixation. Acta Orthopaedica et Traumatologica Turcica, Cilt: 52 - Sayı: 4, 294–298. https://ajindex.com/articles/353513

References (8)

  1. Tsai CH, Fong YC, Chen YH, Hsu CJ, Chang CH, Hsu HC. The epidemiology of traumatic humeral shaft fractures in Taiwan. Int Orthop. 2009;33(2):463e467. https://doi.org/10.1007/s00264-008-0537-8.
  2. Elton SG, Rizzo M. Management of radial nerve injury associated with humeral shaft fractures: an evidence-based approach. J Reconstr Microsurg. 2008;24(8): 569e573. https://doi.org/10.1055/s-0028-1090623.
  3. Ouyang H, Xiong J, Xiang P, Cui Z, Chen L, Yu B. Plate versus intramedullary nail fixation in the treatment of humeral shaft fractures: an updated meta-analysis. J Shoulder Elbow Surg. 2013;22(3):387e395. https://doi.org/10.1016/ j.jse.2012.06.007. Bleeker WA, Nijsten MW, ten Duis HJ. Treatment of humeral shaft fractures related to associated injuries. A retrospective study of 237 patients. Acta Orthop Scand. 1991;62(2):148e153. https://doi.org/10.3109/17453679108999244.
  4. Walker M, Palumbo B, Badman B, Brooks J, Van Gelderen J, Mighell M. Humeral shaft fractures: a review. J Shoulder Elbow Surg. 2011;20(5):833e844. https:// doi.org/10.1016/j.jse.2010.11.030. Prasarn ML, Ahn J, Paul O, et al. Dual plating for fractures of the distal third of the humeral shaft. J Orthop Trauma. 2011;25(1):57e63. https://doi.org/ 10.1097/BOT.0b013e3181df96a7. Holdsworth BJ, Mossad MM. Fractures of the adult distal humerus. Elbow function after internal fixation. J Bone Joint Surg Br. 1990;72(3):362e365. https://doi.org/10.1302/0301-620X.72B3.2341427.
  5. Huang TL, Chiu FY, Chuang TY, Chen TH. Surgical treatment of acute displaced fractures of adult distal humerus with reconstruction plate. Injury. 2004;35(11):1143e1148. https://doi.org/10.1016/j.injury.2003.11.018.
  6. Jupiter JB, Neff U, Holzach P, Allgower M. Intercondylar fractures of the hu- € merus. An operative approach. J Bone Joint Surg Am. 1985;67(2):226e239. Price DD, McGrath PA, Rafii A, Buckingham B. The validation of visual analogue scales as ratio scale measures for chronic and experimental pain. Pain. 1983;17(1):45e56. https://doi.org/10.1016/0304-3959(83)90126-4.
  7. Tejwani NC, Murthy A, Park J, McLaurin TM, Egol KA, Kummer FJ. Fixation of extra-articular distal humerus fractures using one locking plate versus two reconstruction plates: a laboratory study. J Trauma. 2009;66(3):795e799. https://doi.org/10.1097/TA.0b013e318181e53c.
  8. Ilyas AM, Jupiter JB. Treatment of distal humerus fractures. Acta Chir Orthop Traumatol Cech. 2008;75(1):6e15. Jeong BO, Lee DK. Treatment for type C fractures of the distal humerus with the LCP distal hum