A rare case of delayed hypersensitivity reaction to metal ions secondary to a remnant pedicle screw fragment after spinal arthrodesis

Pages
461–464
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

On postoperative day one, theitching was completely resolved, although the skin patch test remained positive.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Delayed hypersensitivity reaction to metal ions is rare and has been mostly documented among patients undergoing totaljoint arthroplasty with metal-on-metal bearing surfaces.
📊
Key Findings & Data:The aim of this case report was to describe the clinical features of arare case of delayed-type hypersensitivity reaction to nickel that occurred after an extraordinarily long period of time (approximately 15 years) after spinal arthrodesis.
💡
Conclusion & Impact:On postoperative day one, theitching was completely resolved, although the skin patch test remained positive.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Delayed hypersensitivity reaction to metal ions is rare and has been mostly documented among patients undergoing totaljoint arthroplasty with metal-on-metal bearing surfaces. Nonetheless, to our knowledge, only a few cases associated withspinal arthrodesis have been reported in the literature. The aim of this case report was to describe the clinical features of arare case of delayed-type hypersensitivity reaction to nickel that occurred after an extraordinarily long period of time (approximately 15 years) after spinal arthrodesis. Here, we present a 38-year-old patient who was referred to us with a diagnosisof delayed-type hypersensitivity reaction to nickel that was established by a skin patch test. The chief sign and symptoms ofthe patient were allergic contact dermatitis along with intractable, generalized itching that started several months ago. Themedical history revealed that the patient had undergone spinal arthrodesis using rods and pedicle screws approximately 15years ago, followed by revision surgery to remove the implants. Radiological examination showed a remnant pedicle screwfragment at the third lumbar vertebra that had broken off during the removal of implants nine years ago. However, thesigns and symptoms of metal hypersensitivity started shortly before the patient was referred to our hospital. We decided toremove the screw fragment as allergic contact dermatitis was refractory to medical treatment. On postoperative day one, theitching was completely resolved, although the skin patch test remained positive.

🔖

Cite This Article

KIM, J. (2020). A rare case of delayed hypersensitivity reaction to metal ions secondary to a remnant pedicle screw fragment after spinal arthrodesis. Acta Orthopaedica et Traumatologica Turcica, Cilt: 54 - Sayı: 4, 461–464. https://ajindex.com/articles/353488

References (14)

  1. Bao W, He Y, Fan Y, Liao Y. Metal allergy in total-joint arthroplasty: Case report and literature review. Medicine (Baltimore) 2018
  2. e12475. doi: 10.1097/MD.0000000000012475. [Crossref] 2. Shang X, Wang L, Kou D, et al. Metal hypersensitivity in patient with posterior lumbar spine fusion: a case report and its literature review. BMC Musculoskelet Disord 2014
  3. doi: 10.1186/1471-2474-15-314. [Crossref] 3. Akil S, Newman JM, Shah NV, Ahmed N, Deshmukh AJ, Maheshwari AV. Metal hypersensitivity in total hip and knee arthroplasty: Current concepts. J Clin Orthop Trauma 2018
  4. [Crossref] 4. Teo WZW, Schalock PC. Metal hypersensitivity reactions to orthopedic implants. Dermatol Ther (Heidelb) 2017
  5. [Crossref] 5. Atanaskova Mesinkovska N, Tellez A, Molina L, et al. The effect of patch testing on surgical practices and outcomes in orthopedic patients with metal implants. Arch Dermatol 2012
  6. [Crossref] 6. Hallab N, Merritt K, Jacobs JJ. Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg Am 2001
  7. [Crossref] 7. Golish SR, Anderson PA. Bearing surfaces for total disc arthroplasty: metal-on-metal versus metal-on-polyethylene and other biomaterials. Spine J 2012
  8. [Crossref] 8. del Rio J, Beguiristain J, Duart J. Metal levels in corrosion of spinal implants. Eur Spine J 2007
  9. [Crossref] 9. Guyer RD, Shellock J, MacLennan B, et al. Early failure of metal-on-metal artificial disc prostheses associated with lymphocytic reaction: diagnosis and treatment experience in four cases. Spine (Phila Pa 1976) 2011
  10. [Crossref] 10. Zairi F, Remacle JM, Allaoui M, Assaker R. Delayed hypersensitivity reaction caused by metal-on-metal total disc replacement. J Neurosurg Spine 2013
  11. [Crossref] 11. Goodwin ML, Spiker WR, Brodke DS, Lawrence BD. Failure of facet replacement system with metal-on-metal bearing surface and subsequent discovery of cobalt allergy: report of 2 cases. J Neurosurg Spine 2018
  12. [Crossref] 12. Alinaghi F, Bennike NH, Egeberg A, Thyssen JP, Johansen JD. Prevalence of contact allergy in the general population: A systematic review and meta-analysis. Contact Dermatitis 2019
  13. [Crossref] 13. Furrer S, Scherer Hofmeier K, Grize L, Bircher AJ. Metal hypersensitivity in patients with orthopaedic implant complications-A retrospective clinical study. Contact Dermatitis 2018
  14. [Crossref] 14. Crawford GH. The role of patch te