Investigation of fungal volatile organic compounds in hospital air

Pages
659–663
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The airborne fungalspectrum revealed the existence of 19 genera, composed predominantly by hyaline filamentous deuteromycetes.Analysis with periodic monitoring is still needed to allow improvement in the data quality.Also, further discussion on the subject in the academic and legislative environment is needed tocontribute to the systematic study of aerobiology

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Fungal growth within the structure of buildings or in ventilation filters generates “hidden contamination”,which cannot be detected only through visual inspection.
📊
Key Findings & Data:In total, 48 samples (60.5% positive) were analyzed for FVOCs; 7 were detected inat least one of the sectors analyzed, with 2-heptanone (179.5 mg/m3) and 2-methyl-1-propanol (121.5 mg/m3) as the most abundant.
💡
Conclusion & Impact:The airborne fungalspectrum revealed the existence of 19 genera, composed predominantly by hyaline filamentous deuteromycetes.Analysis with periodic monitoring is still needed to allow improvement in the data quality.Also, further discussion on the subject in the academic and legislative environment is needed tocontribute to the systematic study of aerobiology
🔬Design:Research Article
📍Scope:48 samples
⚙️Variables:Domain Parameters

Özet

Fungal growth within the structure of buildings or in ventilation filters generates “hidden contamination”,which cannot be detected only through visual inspection. At the beginning of development, thefungi release fungal volatile organic compounds (FVOCs) into the atmosphere, which can originate frommetabolic pathways or from the enzymatic degradation of materials. This study analyzed the air qualityof a public referral hospital in Fortaleza, Ceara, Brazil in terms of FVOCs, to establish ways to improve methods of monitoring and control of specific sectors in the hospital. For that, we created and validated aprotocol for detection of FVOCs, using GC/MS, while fungal samples were identified by analysis of macroand micromorphology. In total, 48 samples (60.5% positive) were analyzed for FVOCs; 7 were detected inat least one of the sectors analyzed, with 2-heptanone (179.5 mg/m3) and 2-methyl-1-propanol (121.5 mg/m3) as the most abundant. With respect to fungal findings, 24 samples were analyzed, with a highnumber of colony-forming units per cubic meter (CFU/m3) observed in all sectors. The airborne fungalspectrum revealed the existence of 19 genera, composed predominantly by hyaline filamentous deuteromycetes.Analysis with periodic monitoring is still needed to allow improvement in the data quality.Also, further discussion on the subject in the academic and legislative environment is needed tocontribute to the systematic study of aerobiology

🔖

Cite This Article

PANTOJA, L. D. M., NASCİMENTO, R. F. D., NUNES, A. B. D. A. (2016). Investigation of fungal volatile organic compounds in hospital air. Atmospheric Pollution Research, Cilt: 7 - Sayı: 4, 659–663. https://ajindex.com/articles/351592

References (2)

  1. Araki, A., Eitaki, Y., Kawai, T., Kanazawa, A., Takeda, M., Kishi, R., 2009. Diffusive sampling and measurement of microbial volatile organic compounds in indoor air. Indoor Air 19, 421e432. Bastos, J.E., 2005. Requisitos para a garantia de qualidade do ar em ambientes climatizados e enfoque em ambientes hispitalares. Monografia de Especializaçao em Engenharia de Segurança do Trabalho. CTC. UFSC, p. 110. Orientador: Henrique de Melo Lisboa. Bogomolova, E., Kirtsideli, I., 2009. Airborne fungi in four stations of the St. Petersburg Underground railway system. Int. Biodeterior. Biodegrad. 63, 156e160. Brasil, 2003. Anvisa - Agencia Nacional de Vigilancia Sanitaria. Orientaç ao tecnica elaborada por grupo tecnico assessor sobre padr oes referenciais de qualidade do ar interior em ambientes climatizados artificialmente de uso público e coletivo. RE nº 9, de 16 de janeiro de 2003.
  2. Demyttenaerea, J.C.R., Morinaa, R.M., Kimpea, N., Sandrab, P., 2004. Use of head- ~ space solid-phase microextraction and headspace sorptive extraction for the detection of the volatile metabolites produced by toxigenic Fusarium species. J. Chromatogr. A 1027, 147e154. Diniz-Martins, J.N., Silva, R.A.M., Miranda, E.T., Mendes-Giannini, M.J.S., 2005. Monitoramento de fungos anemofilos e de leveduras em unidade hospitalar. Rev. Saúde Pública 39, 22e34. Fiedler, K., Schutz, E., Geh, S., 2001. Detection of microbial volatile organic compounds (MVOCs) produced by moulds on various materials. Int. J. Hyg. Environ. Health 204, 111e121. Gil, A.C., 2007. Como elaborar projetos de pesquisa, fourth ed. Atlas, Sao Paulo. Harper, M., 2000. Sorbent trapping of volatile organic compounds from air. J. Chromatogr. A 855, 129e151. Hess-Kosa, K., 2002. Indoor Quality: Sampling Methodologies. CRC Lewis Publishers, Boca Raton, p. 320. Hoog, G.S., Guarro, J., Gene, J., Figueiras, J., 2000. Atlas of Clinical Fungi, second ed. Delf: Centraalbureau voor Schinmel culture/Universitat Rovira i Virgilli. Kim, J.L., Elfman, L., Mi, Y., Wieslander, G., Smedje, G., Norback, D., 2007. Indoor molds, bacteria, microbial volatile organic compounds and plasticizers in schoolseassociations with asthma and respiratory symptoms in pupils. Indoor Air 17, 153e163. Lancker, F., Adams, A., Delmulle, B., Saeger, S., Moretti, A., Peteghem, C., Kimpe, N., 2008. Use of headspace SPME-CG-MS for the analysis of the volatiles produced by indoor molds grown on different substrates. J. Environ. Monit. 10, 1127e1133. Lang-Yona, N., Shus