Indoor air quality investigation of the school environment and estimated health risks: Two-season measurements in primary schools in Kozani, Greece

Pages
1128–1142
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The ventilation rate for each classroom was calculated based on theCO2 measurements.Results indicated that indoor air concentrations of the measured pollutants were within acceptedlimits with indicative ranges 1.5e9.4 mg/m3 for benzene, 2.3e28.5 mg/m3 for formaldehyde, 4.6e43 mg/m3 for NO2 and 0.1e15.6 mg/m3 for O3.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Two primary schools and one kindergarten were selected in the city of Kozani, Greece in order toinvestigate the school environment, the indoor air pollutants that children are exposed to and possiblehealth risks at school.
📊
Key Findings & Data:In each school three classrooms and one outdoor position were monitored fromMonday to Friday, in both non-heating (26/09/2011e14/10/2011) and heating (23/01/2012e10/02/2012)period.
💡
Conclusion & Impact:The ventilation rate for each classroom was calculated based on theCO2 measurements.Results indicated that indoor air concentrations of the measured pollutants were within acceptedlimits with indicative ranges 1.5e9.4 mg/m3 for benzene, 2.3e28.5 mg/m3 for formaldehyde, 4.6e43 mg/m3 for NO2 and 0.1e15.6 mg/m3 for O3.
🔬Design:Research Article
📍Scope:2011 Verileri
⚙️Variables:Domain Parameters

Özet

Two primary schools and one kindergarten were selected in the city of Kozani, Greece in order toinvestigate the school environment, the indoor air pollutants that children are exposed to and possiblehealth risks at school. In each school three classrooms and one outdoor position were monitored fromMonday to Friday, in both non-heating (26/09/2011e14/10/2011) and heating (23/01/2012e10/02/2012)period. Temperature, relative humidity and CO2, were continuously monitored. Formaldehyde, benzene,trichloroethylene, pinene, limonene, NO2 and O3 were measured with diffusive samplers. CO wasmonitored every day (30 min/day). Radon was measured for four weeks with short term radon detectors.PM2.5 was gravimetrically determined while PM2.5 and PM10 fractions were measured using the opticallight scattering technique. Building material emission testing for VOCs was performed using the Fieldand Laboratory Emission Cell (FLEC). The ventilation rate for each classroom was calculated based on theCO2 measurements.Results indicated that indoor air concentrations of the measured pollutants were within acceptedlimits with indicative ranges 1.5e9.4 mg/m3 for benzene, 2.3e28.5 mg/m3 for formaldehyde, 4.6e43 mg/m3 for NO2 and 0.1e15.6 mg/m3 for O3. Emissions from building materials seem to have a significantcontribution to the indoor air quality. Very low ventilation rates (0.1e3.7 L/s per person) were observed,indicating inadequate ventilation and possible indoor air quality problems requiring intervention measures.The estimated average lifetime cancer risks for benzene, formaldehyde and trichloroethylene werevery low.

🔖

Cite This Article

KALİMERİ, K. K., SARAGA, D. E., LAZARİDİS, V. D., LEGKAS, N. A., MİSSİA, D. A., TOLİS, E. I., BARTZİS, J. G. (2016). Indoor air quality investigation of the school environment and estimated health risks: Two-season measurements in primary schools in Kozani, Greece. Atmospheric Pollution Research, Cilt: 7 - Sayı: 6, 1128–1142. https://ajindex.com/articles/351523

References (2)

  1. Almeida, S.M., Canha, N., Silva, A., do Carmo Freitas, M., Pegas, P., Alves, C., Evtyugina, M., Adriao Pio, C., 2011. Children exposure to atmospheric particles ~ in indoor of Lisbon primary schools. Atmos. Environ. 45, 7594e7599. American Thoracic Society, 1996. Health effects of outdoor air pollution. Am. J. Respir. Crit. Care. Med. 153, 3e50. Annesi-Maesano, I., Baiz, N., Banerjee, S., Rudnai, P., Rive, S., on behalf of the SINPHONIE Group, 2013. Indoor air quality and sources in schools and related health effects. J. Toxicol. Environ. Health, Part B 16 (8), 491e550. http:// dx.doi.org/10.1080/10937404.2013.853609. ASHRAE, 2001. Ventilation for Acceptable Indoor Air Quality. American Society of Heating, Refrigerating and air-conditioning engineers, Inc., Atlanta (ANSI/ ASHRAE Standard 62e2001). ASHRAE, 2004. Thermal environmental Conditions for Human Occupancy. American Society of Heating, Refrigerating and air-conditioning engineers, Inc, Atlanta, GA (ANSI/ASHRAE Standard 55e2004). ASTM 5116, 1997. Standard Guide for Small-scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/products. ASTM International, West Conshohocken. ASTM D6245, 2007. Standard Guide for Using Indoor Carbon Dioxide Concentrations to Evaluate Indoor Air Quality and Ventilation. ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428e2959,United States. Bako-Bir o, Zs, Clements-Croome, D.J., Kochhar, N., Awbi, H.B., Williams, M.J., 2012. Ventilation rates in schools and pupils' performance. Build. Environ. 48, 215e223. Branis, M.,Safranek, J., 2011. Characterization of coarse particulate matter in school gyms. Environ. Res. 111, 485e491. Brown, S.K., 1997. Indoor Air Quality. Australia: State of the Environment Technical Paper Series (Atmosphere), p. 68. BUMA, 2006. BUMA (Prioritizitation of BUilding Materials as Indoor Pollution Sources) Database. http://www.uowm.gr/bumaproject/ (last accessed on 12/04/ 2015). BUMAC, 2013. Consumer Product Emission Database. http://bumac.uowm.gr/ (last accessed on 24/06/2016). Cal 14, 2014. California Office of Environmental Health Hazard Assessment (OEHHA). All OEHHA Acute, 8-hour and Chronic Reference Exposure Levels as of June 2014.