Journals / Atmospheric Pollution Research / 2016 / Cilt: 7 - Sayı: 5

On the influence of viaduct and ground heating on pollutant dispersion in 2D street canyons and toward single-sided ventilated buildings

Pages
817–832
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Results show that viaduct significantly reduces overall spatial mean indoor concentrations ofgaseous pollutant ( ) and indoor particle number (PN) in all rooms being the elevated pollutantsource above the viaduct compared to those without the viaduct.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:This paper employs Computational Fluid Dynamic (CFD) simulations to investigate the influence ofground heating intensities and viaduct configurations on gaseous and particle dispersion within twodimensionalidealized street canyons (typical aspect ratio H/W ¼ 1) and their transport from outdoorto leeward and windward rooms of naturally-ventilated buildings.
📊
Key Findings & Data:Results show that viaduct significantly reduces overall spatial mean indoor concentrations ofgaseous pollutant ( ) and indoor particle number (PN) in all rooms being the elevated pollutantsource above the viaduct compared to those without the viaduct.
💡
Conclusion & Impact:Although further investigations are still required to propose apractical framework on viaduct design, this paper is one of the first attempts to study the effect of viaducton street pollutant dispersion.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

This paper employs Computational Fluid Dynamic (CFD) simulations to investigate the influence ofground heating intensities and viaduct configurations on gaseous and particle dispersion within twodimensionalidealized street canyons (typical aspect ratio H/W ¼ 1) and their transport from outdoorto leeward and windward rooms of naturally-ventilated buildings. Without viaduct, the ground heatingexists at the street ground above which the pollutant source is located, while in the presence of viaductthe ground heating only occurs at the viaduct ground surface and pollutant source is slightly above theviaduct. Results show that viaduct significantly reduces overall spatial mean indoor concentrations ofgaseous pollutant ( ) and indoor particle number (PN) in all rooms being the elevated pollutantsource above the viaduct compared to those without the viaduct. Road barriers on the viaduct slow downthe flow above it and slightly increase indoor , but they reduce indoor PN due to the enhancedparticle deposition onto viaduct surfaces. The uniform heating of street ground or viaduct ground surfacestrengthens recirculation flows in street canyon, reducing and PN of fine particle (diameterd ¼ 1 mm), but for larger particles indoor PN distribution is complicated by the interaction of gravity,buoyancy and wind-induced recirculation. Although further investigations are still required to propose apractical framework on viaduct design, this paper is one of the first attempts to study the effect of viaducton street pollutant dispersion.

🔖

Cite This Article

HANG, J., LİN, M., WONG, D. C., WANG, X., WANG, B., BUCCOLİERİ, R. (2016). On the influence of viaduct and ground heating on pollutant dispersion in 2D street canyons and toward single-sided ventilated buildings. Atmospheric Pollution Research, Cilt: 7 - Sayı: 5, 817–832. https://ajindex.com/articles/351519

References (1)

  1. Ai, Z.T., Mak, C.M., 2014. A study of interunit dispersion around multistory buildings with single-sided ventilation under different wind directions. Atmos. Environ. 88, 1e13. Al-Dabbous, A.N., Kumar, P., 2014. The influence of roadside vegetation barriers on airborne nanoparticles and pedestrians exposure under varying wind conditions. Atmos. Environ. 90, 113e124. Allegrini, J., Dorer, V., Carmeliet, J., 2013. Wind tunnel measurements of buoyant flows in street canyons. Build. Environ. 59, 315e326. Allegrini, J., Dorer, V., Carmeliet, J., 2014. Buoyant flows in street canyons: validation of CFD simulations with wind tunnel measurements. Build. Environ. 72, 63e74. Blocken, B., 2015. Computational fluid dynamics for urban physics: importance, scales, possibilities, limitations and ten tips and tricks towards accurate and reliable simulations. Build. Environ. 91, 219e245. Blocken, B., Stathopoulos, T., Carmeliet, J., 2007. CFD simulation of the atmospheric boundary layer: wall function problems. Atmos. Environ. 41, 238e252. Buccolieri, R., Salizzoni, P., Soulhac, L., Garbero, V., Di Sabatino, S., 2015. The breathability of compact cities. Urb. Clim. 13, 73e93. Cai, X., 2012. Effects of differential wall heating in street canyons on dispersion and ventilation characteristics of a passive scalar. Atmos. Environ. 51, 268e277. Chavez, M., Hajra, B., Stathopoulos, T., Bahloul, A., 2011. Near-field pollutant dispersion in the built environment by CFD and wind tunnel simulations. J. Wind Eng. Ind. Aerodyn. 99, 330e3309. Chen, C., Zhao, B., Zhou, W., Jiang, X., Tan, Z., 2012. A methodology for predicting particle penetration factor through cracks of windows and doors for actual engineering application. Build. Environ. 47, 339e348. Di Sabatino, S., Buccolieri, R., Olesen, H.R., Ketzel, M., Berkowicz, R., Franke, J., Schatzmann, M., Schlunzen, K.H., Leitl, B., Britter, R., Borrego, C., Costa, A.M., Trini Castelli, A., Reisin, T.G., Hellsten, A., Saloranta, J., Moussiopoulos, N., Barmpas, F., Brzozowski, K., Goricsan, I., Balczo, M., Bartzis, J.G., Efthimiou, G., Santiago, J.L., Martilli, A., Piringer, M., Baumann-Stanzer, K., Hirtl, M., Baklanov, A.A., Nuterman, R.B., Starchenko, A.V., 2011. COST 732 in practice: the MUST model evaluation exercise. Int. J. Env. Poll. 44, 403e418. Di Sabatino, S., Buccolieri, R., Salizzoni, P., 2013. Recent advancements in numerical modelling of flow and dispersion in urban areas: a short review. Int. J. Environ. Pollut. 52, 172e191. F