Journals / Atmospheric Pollution Research / 2020 / Cilt: 11 - Sayı: 3

Mapping the geospatial distribution of atmospheric BTEX compounds using portable mass spectrometry and adaptive whole air sampling

Pages
545–553
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Laboratory based comparisons using lab constructed air samples showed thepercent difference in quantitation between MIMS and WAS to be within 20% across targeted analytes in the lowppbv concentration range.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Atmospheric environmental monitoring with mobile laboratories is becoming more common as instrumentationevolves and the benefits of taking the lab-to-sample are realized.
📊
Key Findings & Data:Field campaigns involved continuous ambient-air sampling from a movingvehicle (collected at ~ 1 Hz).
💡
Conclusion & Impact:Laboratory based comparisons using lab constructed air samples showed thepercent difference in quantitation between MIMS and WAS to be within 20% across targeted analytes in the lowppbv concentration range.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Atmospheric environmental monitoring with mobile laboratories is becoming more common as instrumentationevolves and the benefits of taking the lab-to-sample are realized. One of the benefits of this approach is theability to screen a geographic area for compounds of interest and to use ‘real-time’ data to inform adaptivesampling. We report on the use of a membrane introduction mass spectrometer (MIMS) for continuous monitoring of atmospheric volatile organic compounds (VOCs) associated with hydrocarbon upgrading and refiningfacilities in northern Alberta, Canada. Field campaigns involved continuous ambient-air sampling from a movingvehicle (collected at ~ 1 Hz). Real-time MIMS data were used to monitor chemical concentrations of benzene,toluene, and ethylbenzene/xylenes (BTEX) and to prompt collection whole air sample (WAS) canisters for laboratory-based, trace-level VOC speciation and quantitation. The MIMS data showed a high degree of spatiotemporal variability, which allowed for near real-time feedback to guide otherwise subjective or random collection of whole air samples. Laboratory based comparisons using lab constructed air samples showed thepercent difference in quantitation between MIMS and WAS to be within 20% across targeted analytes in the lowppbv concentration range.

🔖

Cite This Article

DAVEY, N. G., BELL, R. J., GILL, C. G., KROGH, E. T. (2020). Mapping the geospatial distribution of atmospheric BTEX compounds using portable mass spectrometry and adaptive whole air sampling. Atmospheric Pollution Research, Cilt: 11 - Sayı: 3, 545–553. https://ajindex.com/articles/351438

References (10)

  1. Atkinson, R., 2000. Atmospheric chemistry of VOCs and NOx. Atmos. Environ. 34, 2063–2101.
  2. Badman, E.R., Cooks, R.G., 2000. Special feature: perspective - Miniature mass analyzers. J. Mass Spectrom. 35, 659–671.
  3. Bell, R.J., Davey, N.G., Martinsen, M., Collin-Hansen, C., Krogh, E.T., Gill, C.G., 2015a. A field-portable membrane introduction mass spectrometer for real-time quantitation and spatial mapping of atmospheric and aqueous contaminants. J. Am. Soc. Mass Spectrom. 26, 212–223.
  4. Bell, R.J., Davey, N.G., Martinsen, M., Short, R.T., Gill, C.G., Krogh, E.T., 2015b. The effect of the Earth's and stray magnetic fields on mobile mass spectrometer systems. J. Am. Soc. Mass Spectrom. 26, 201–211.
  5. Bier, M.E., Cooks, R.G., 1987. Membrane interface for selective introduction of volatile compounds directly into the ionization-chamber of a mass-spectrometer. Anal. Chem. 59, 597–601.
  6. Chen, C.H., Chen, T.C., Zhou, X.Y., Kline-Schoder, R., Sorensen, P., Cooks, R.G., Ouyang, Z., 2015. Design of portable mass spectrometers with handheld probes: aspects of the sampling and miniature pumping systems. J. Am. Soc. Mass Spectrom. 26, 240–247.
  7. Chen, Q.F., Milburn, R.K., Karellas, N.S., 2006. Real time monitoring of hazardous airborne chemicals: a styrene investigation. J. Hazard Mater. 132, 261–268.
  8. D'Autry, W., Wolfs, K., Yarramraju, S., Van Schepdael, A., Hoogmartens, J., Adams, E., 2010. Characterization and improvement of signal drift associated with electron ionization quadrupole mass spectrometry. Anal. Chem. 82, 6480–6486.
  9. Davey, N.G., Krogh, E.T., Gill, C.G., 2011. Membrane introduction mass spectrometry (MIMS). Trends Anal. Chem. 30, 1477–1485. de Gouw, J., Warneke, C., 2007. Measurements of volatile organic compounds in the earths atmosphere using proton-transfer-reaction mass spectrometry. Mass Spectrom. Rev. 26, 223–257. EPA, 2016. Volatile organic compounds' impact on indoor air quality. https://www.epa. gov/indoor-air-quality-iaq/volatile-organic-compounds-impact-indoor-air-quality, Accessed date: 15 September 2019. EPA, 1999a.
  10. Air Method, Toxic Organics-15 (TO-15): Compendium of Methods for the Determination of Toxic Organic Compounds in Ambient Air, second ed. Determination of Volatile Organic Compounds (VOCs) in Air Collected in SpeciallyPrepared Canisters and Analyzed by Gas Chromatography/Mass Spectrometry (GC/ MS). https://www3.epa.gov/ttnamti1/files/ambient/airtox/to-17r.pdf, Accessed date: 15 September 2019. EPA, 1999b. Method TO-17: determination of vola