Evaluation of two indoor air pollution abatement techniques in forced-ventilation fattening pig barns

Pages
482–438
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The results indicated that the average reduction efficiencies were 63% for total PM, 61% for PM10 and 32% for NH3.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Animal agricultural activities can be a significant source of pollutants affecting the health of farmers and neighboring communities.
📊
Key Findings & Data:The main objective of this research was to improve the air quality by reducing the interior concentrations of emitting pollutants such as particulate matter (PM) and ammonia (NH3) within forced-ventilated fattening pig barns in order to improve the working conditions for human and the living conditions for animals as well as to have less impact on the surrounding environment.
💡
Conclusion & Impact:The results indicated that the average reduction efficiencies were 63% for total PM, 61% for PM10 and 32% for NH3.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Animal agricultural activities can be a significant source of pollutants affecting the health of farmers and neighboring communities. The main objective of this research was to improve the air quality by reducing the interior concentrations of emitting pollutants such as particulate matter (PM) and ammonia (NH3) within forced-ventilated fattening pig barns in order to improve the working conditions for human and the living conditions for animals as well as to have less impact on the surrounding environment. The mitigation techniques were a recirculating air scrubber and spraying of a watereoil mixture. The reduction efficiencies of the two mitigation techniques for PM and NH3 concentrations inside the barns were investigated. Two air scrubbers were mounted in a barn occupied with 515 pigs. A watereoil mixture spraying system with two different nozzles geometries was installed in a barn with 680 pigs. The data obtained from the mitigation system was compared with that obtained from a control barn with the same animal capacity and conditions. The results indicated that the average reduction efficiencies were 63% for total PM, 61% for PM10 and 32% for NH3. The results indicated that the average reduction effi-ciencies of the spraying system for the whole periods were 74% for total PM, 72% for PM10 and 19.5% for NH3 when using small nozzles and 44% for total PM, 39% for PM10 and 16% for NH3 when using large nozzles. The spraying system reduced the germs and fungal spore concentrations by 14 and 58%, respectively.

🔖

Cite This Article

Mostafa, E., Hoelscher, R., Diekmann, B., Ghaly, A., Buescher, W. (2017). Evaluation of two indoor air pollution abatement techniques in forced-ventilation fattening pig barns. Atmospheric Pollution Research, Cilt: 8 - Sayı: 3, 482–438. https://ajindex.com/articles/351399

References (1)

  1. Yang, X., 2010. Physical, chemical and biological properties of airborne particles emitted from animal confinement buildings. Ph.D. dissertation. Agricultural and Biological Engineering Department, University of Illinois at Urbana-Champaign, USA. Xu, W., Zheng, K., Meng, L., Liu, X., Hartung, E., Roelcke, M., Zhang, F., 2016. Con-centrations and emissions of particulate matter from intensive pig production at a large farm in north China. Aerosol Air Qual. Res. 16, 79e90. http:// dx.doi.org/10.4209/aaqr.2015.02.0078. Xu, W., Zheng, K., Liu, X., Meng, L., Huaitalla, R.M., Shen, J., Hartung, E., Gallmann, E., Roelcke, M., Zhang, F., 2014. Atmospheric NH3 dynamics at a typical pig farm in China and their implications. Atmos. Pollut. Res. 5, 455e463. http://dx.doi.org/ 10.5094/APR.2014.053. Winkel, A., Mosquera, J., Aarnink, A.J.A., Koerkamp, P.W.G.G., Ogink, N.W.M., 2015. Evaluation of a dry filter and an electrostatic precipitator for exhaust air cleaning at commercial non-cage laying hen houses. Biosystems Eng. 129, 212e225. Watt, A.C., Aziz, S.M., Banzhazi, T.M., 2010. Air pollution and livestock production. In: World Congress of the International Commission of Agricultural and Bio-systems Engineering (CIGR) XVIIth. Quebec City, Canada. June 13e17. Wathes, C.M., Jones, J.B., Kristensen, H.H., Jones, E.K.M., Webster, A.J.F., 2002. A version of pigs and domestic fowl to atmospheric ammonia. Trans. ASAE 45, 1605e1610. Wang, X., Zhang, Y., Zhao, L.Y., Riskowski, G.L., 2000. Effect of ventilation rate on dust spatial distribution in mechanically ventilated airspace. ASAE 43 (6), 1877e1884. VDI 4252 and 4253 Part 2, 2004. Measurement of Airborne Microorganisms and Viruses in Ambient Air e Active Sampling of Bioaerosols e Separation of Airborne Mould on Gelatine/polycarbonate Filters. Beuth-Verlag, Berlin, Germany. Ullman, J.L., Mukhtar, S., Lacey, R.E., Carey, J.B., 2004. A review of literature con-cerning odours, ammonia, and dust from broiler production facilities: 4. Remedial management practices. J. Appl. Poult. Res. 13, 521e531. Ulens, T., Millet, S., Van Ransbeeck, N., Van Weyenberg, S., Van Langenhove, H., Demeyer, P., 2014. The effect of different pen cleaning techniques and housing systems on indoor concentrations of particulate matter, ammonia and green-house gases (CO2, CH4, N2O). Livest. Sci. 159, 123e132. Snell, H.G.J., Schwarz, A., 2003. Development of an efficient bioscrubber system for the reduction of emissions. In: ASAE Annual International Meet