⚡ TL;DR(Too Long; Didn't Read)

These findings indicate that the environmental temperature does notaffect the stability of PAHs in PAS.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Passive air samplers (PAS) have become recurrent methods for environmental monitoring.
📊
Key Findings & Data:The gradient of temperature insideand outside the PAS was firstly determined, being noted an internal/external difference of up to 5 C.Secondly, a lab-controlled experiment was performed by daily analyzing PAHs in PUF-based PAS exposedto 25 C and 38 C, for a period of 7 days.
💡
Conclusion & Impact:These findings indicate that the environmental temperature does notaffect the stability of PAHs in PAS.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Passive air samplers (PAS) have become recurrent methods for environmental monitoring. However, theinfluence of environmental variables, such as temperature, over these devices has not been fullyinvestigated. Since climate change is likely to induce major environmental changes, the role of thetemperature needs to be studied to assure the suitability of PAS for the long-term monitoring of semivolatile organic compounds (SVOCs) and their utility to compare data from different locations. Thisstudy aimed at evaluating the potential loss of polycyclic aromatic hydrocarbons (PAHs) in PAS containing disks of polyurethane foam (PUF) at different temperatures. The gradient of temperature insideand outside the PAS was firstly determined, being noted an internal/external difference of up to 5 C.Secondly, a lab-controlled experiment was performed by daily analyzing PAHs in PUF-based PAS exposedto 25 C and 38 C, for a period of 7 days. A significant loss of PAHs in PUFs was not observed for any ofboth scenarios, remaining constant through time. Moreover, PAH levels were not significantly differentaccording to the temperature. These findings indicate that the environmental temperature does notaffect the stability of PAHs in PAS. Once PAHs have been uptaken, they are not easily volatilized fromthese devices. Consequently, PAS are good environmental monitors independently on the ambientconditions of temperature, being suitable for the comparability of data, either temporally or spatially, onthe airborne concentrations of PAHs.

🔖

Cite This Article

MORUECO, N. D., SCHUHMACHER, M., SİERRA, J., NADAL, M., DOMİNGO, J. L. (2016). Assessment of PAH loss in passive air samplers by the effect of temperature. Atmospheric Pollution Research, Cilt: 7 - Sayı: 1, 142–146. https://ajindex.com/articles/351104

References (1)

  1. Armstrong, J.L., Yost, M.G., Fenske, R.A., 2014. Development of a passive air sampler to measure airborne organophosphorus pesticides and oxygen analogs in an agricultural community. Chemosphere 111, 135e143. Bogdal, C., Scheringer, M., Abad, E., Abalos, M., van Bavel, B., Hagberg, J., Fiedler, H., 2013. Worldwide distribution of persistent organic pollutants in air, including results of air monitoring by passive air sampling in five continents. TrAC Trends Anal. Chem. 46, 150e161. Bohlin, P., Jones, K.C., Tovalin, H., Strandberg, B., 2008. Observations on persistent organic pollutants in indoor and outdoor air using passive polyurethane foam samplers. Atmos. Environ. 42, 7234e7241. Chaemfa, C., Barber, J.L., Gocht, T., Harner, T., Holoubek, I., Klanov a, J., Jones, K.C., 2008. Field calibration of polyurethane foam (PUF) disk passive air samplers for PCBs and OC pesticides. Environ. Pollut. 156, 1290e1297. Chen, Y., Feng, Y., Xiong, S., Liu, D., Wang, G., Sheng, G., Fu, J., 2011. Polycyclic aromatic hydrocarbons in the atmosphere of Shanghai, China. Environ. Monit. Assess. 172, 235e247. Choi, S.D., Kwon, H.O., Lee, Y.S., Park, E.J., Oh, J.Y., 2012. Improving the spatial resolution of atmospheric polycyclic aromatic hydrocarbons using passive air samplers in a multi-industrial city. J. Hazard. Mater. 241e242, 252e258. Estellano, V.H., Pozo, K., Harner, T., Corsolini, S., Focardi, S., 2012. Using PUF disk passive samplers to simultaneously measure air concentrations of persistent organic pollutants (POPs) across the Tuscany region, Italy. Atmos. Pollut. Res. 3, 88e94. Kennedy, K., 2010. Effect based monitoring of seasonal ambient air exposures in Australia sampled by PUF passive air samplers. Atmos. Pollut. Res. 1, 50e58. Klanov a, J., Eupr, P., Kohoutek, J., Harner, T., Kohoutek, I., Harner, T., 2008. Assessing the influence of meteorological parameters on the performance of polyurethane foam-based passive air samplers. Environ. Sci. Technol. 42, 550e555. Mari, M., Schuhmacher, M., Feliubadalo, J., Domingo, J.L., 2008. Air concentrations of PCDD/Fs, PCBs and PCNs using active and passive air samplers. Chemosphere 70, 1637e1643. Melymuk, L., Bohlin, P., S anka, O., Pozo, K., Kl anov a, J., 2014. Current challenges in air sampling of semivolatile organic contaminants: sampling artifacts and their influence on data comparability. Environ. Sci. Technol. 48, 14077e14091. Odabasi, M., Cetin, E., Sofuoglu, A., 2006. Determination of octanol-air partition coeffici