Journals / Diagnostic and Interventional Radiology / 2016 / Cilt: 22 - Sayı: 4

Comparison of effective radiation doses from X-ray, CT, and PET/ CT in pediatric patients with neuroblastoma using a dose monitoring program

Pages
390–394
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

A dose monitoring program can be useful for calculating radiation doses in patients with cancer..

📌 3 Key Takeaways

🎯
Objective & Hypothesis:PURPOSE We aimed to evaluate the use of a dose monitoring program for calculating and comparing the diagnostic radiation doses in pediatric patients with neuroblastoma.
📊
Key Findings & Data:METHODS We retrospectively reviewed diagnostic and therapeutic imaging studies performed on pediatric patients with neuroblastoma from 2003 to 2014.
💡
Conclusion & Impact:A dose monitoring program can be useful for calculating radiation doses in patients with cancer..
🔬Design:Review & Systematic Survey
📍Scope:2003 Verileri
⚙️Variables:Domain Parameters

Abstract

PURPOSE We aimed to evaluate the use of a dose monitoring program for calculating and comparing the diagnostic radiation doses in pediatric patients with neuroblastoma. METHODS We retrospectively reviewed diagnostic and therapeutic imaging studies performed on pediatric patients with neuroblastoma from 2003 to 2014. We calculated the mean effective dose per exam for X-ray, conventional computed tomography (CT), and CT of positron emission tomography/computed tomography (PET/CT) from the data collected using a dose monitoring program (DoseTrack group) since October 2012. Using the data, we estimated the cumulative dose per person and the relative dose from each modality in all patients (Total group). The effective dose from PET was manually calculated for all patients. RESULTS We included 63 patients with a mean age of 3.2±3.5 years; 28 had a history of radiation therapy, with a mean irradiated dose of 31.9±23.2 Gy. The mean effective dose per exam was 0.04±0.19 mSv for X-ray, 1.09±1.11 mSv for CT, and 8.35±7.45 mSv for CT of PET/CT in 31 patients of the DoseTrack group. The mean estimated cumulative dose per patient in the Total group was 3.43±2.86 mSv from X-ray (8.5%), 7.66±6.09 mSv from CT (19.1%), 18.35±13.52 mSv from CT of PET/CT (45.7%), and 10.71±10.05 mSv from PET (26.7%). CONCLUSION CT of PET/CT contributed nearly half of the total cumulative dose in pediatric patients with neuroblastoma. The radiation dose from X-ray was not negligible because of the large number of X-ray images. A dose monitoring program can be useful for calculating radiation doses in patients with cancer..

🔖

Cite This Article

KİM, Y. Y., SHİN, H. J., KİM, M., LEE, M. (2016). Comparison of effective radiation doses from X-ray, CT, and PET/ CT in pediatric patients with neuroblastoma using a dose monitoring program. Diagnostic and Interventional Radiology, Cilt: 22 - Sayı: 4, 390–394. https://ajindex.com/articles/350059

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (4)

  1. NRC. Health risks from exposure to low levels of ionizing radiation: BEIR VII phase 2. Washing- ton, DC: The National Academies Press, 2006; 269-271. ICRP. 1990 Recommendations of the interna- tional commission on radiological protection. Ann ICRP 1991; 21:1-201.
  2. Kornerup JS, Brodin P, Birk Christensen C, et al. Use of PET/CT instead of CT-only when planning for radiation therapy does not notably increase life years lost in children being treated for cancer. Pediatr Radiol 2015; 45:570-581. [CrossRef] Ware DE, Huda W, Mergo PJ, Litwiller AL. Radi- ation effective doses to patients undergoing abdominal CT examinations. Radiology 1999; 210:645-650. [CrossRef] Hennewig U, Kaatsch P, Blettner M, Spix C. Lo- cal radiation dose and solid second malignant neoplasms after childhood cancer in Germany: a nested case-control study. Radiat Environ Biophys 2014; 53:485-493. [CrossRef] Fuji H, Schneider U, Ishida Y, et al. Assessment of organ dose reduction and secondary cancer risk associated with the use of proton beam therapy and intensity modulated radiation therapy in treatment of neuroblastomas. Radi- at Oncol 2013; 8:255-261. [CrossRef] Goske MJ, Applegate KE, Boylan J, et al. The 'Im- age Gently' campaign: increasing CT radiation dose awareness through a national education and awareness program. Pediatr Radiol 2008; 38:265-269. [CrossRef] Pearce MS, Salotti JA, Little MP, et al. Radiation exposure from CT scans in childhood and sub- sequent risk of leukaemia and brain tumours: a retrospective cohort study. Lancet 2012; 380:499-505. [CrossRef] Brenner D, Elliston C, Hall E, Berdon W. Esti- mated risks of radiation-induced fatal cancer from pediatric CT. AJR Am J Roentgenol 2001; 176:289-296. [CrossRef] Matthay KK. Neuroblastoma: biology and ther- apy. Oncology 1997; 11:1857-1866. Rechnitzer C. Increased survival of children with solid tumours: how did we get there and how to keep the success going? Cancer Imag- ing 2011; 11 Spec No A:S65-69. Piccardo A, Lopci E, Conte M, et al. PET/CT im- aging in neuroblastoma. Q J Nucl Med Mol Im- aging 2013; 57:29-39.
  3. Sharp SE, Parisi MT, Gelfand MJ, Yanik GA, Shulkin BL. Functional-metabolic imaging of neuroblastoma. Q J Nucl Med Mol Imaging 2013; 57:6-20.
  4. Severance Children's Hospital, Yonsei University College of Medicine, Seoul, Korea Murano T, Tateishi U, Iinuma T, et al. Evaluation of the risk of radiation exposure from new 18FDG PET/CT plans versus conventional X-ray plans in patients with pediatric cancers. Ann Nucl Me