Journals / Diagnostic and Interventional Radiology / 2020 / Cilt: 26 - Sayı: 6

Side-hole catheters have higher thrombus aspiration efficiency than regular end-hole catheters in an in vitro model

Pages
565–569
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Animal models are needed toexamine their aspiration capacity in a real elastic vascular conduit and in the presence of wall-adherent thrombi.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:PURPOSEWe aimed to evaluate and compare thrombus aspiration efficiency between side-hole and endhole thrombus-aspirating catheters.METHODSUsing an in vitro model of acute thrombus occlusion, we performed thrombus aspiration withtwo catheter designs.
📊
Key Findings & Data:Two end-hole and two side-hole catheters, 8 F and 10 F in diameter, wereexamined.
💡
Conclusion & Impact:Animal models are needed toexamine their aspiration capacity in a real elastic vascular conduit and in the presence of wall-adherent thrombi.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

PURPOSEWe aimed to evaluate and compare thrombus aspiration efficiency between side-hole and endhole thrombus-aspirating catheters.METHODSUsing an in vitro model of acute thrombus occlusion, we performed thrombus aspiration withtwo catheter designs. Two end-hole and two side-hole catheters, 8 F and 10 F in diameter, wereexamined. Thrombus aspiration was performed with each catheter 30 times, and the amount ofthrombotic material aspirated in each attempt was determined. The mean weight of the thrombotic material and the mean weight of the non-fluid thrombotic material extracted in all 30 attempts by each catheter were also determined.RESULTSThe 10 F side-hole catheter aspirated more thrombotic material than did the 10 F end-hole catheter (44.76 g vs. 28.35 g). The 8 F side-hole catheter had higher thrombus aspiration capacitythan did the 8 F end-hole catheter in terms of the mean weight of the aspirated thrombus ateach aspiration attempt (1.41 g vs. 0.58 g; P < 0.001) and the mean volume of the aspiratedthrombotic material at each aspiration attempt (1.79 mL vs. 1.01 mL; P < 0.001). The mean weightof the non-fluid thrombotic material aspirated with the side-hole catheters was higher than thataspirated by the end-hole catheters with the same diameter size (31.06 g vs. 22.41 g for the 10 Fcatheters; P < 0.001; and 4.54 g vs. 2.99 g for the 8 F catheters; P < 0.001).CONCLUSIONSide-hole catheters are more effective in aspirating acute thrombi. The added benefit of theside-hole design is more remarkable in smaller-sized catheters. Animal models are needed toexamine their aspiration capacity in a real elastic vascular conduit and in the presence of wall-adherent thrombi.

🔖

Cite This Article

MOOSAVI, J., SADEGHIPOUR, P., SHAFE, O., ABDI, A. (2020). Side-hole catheters have higher thrombus aspiration efficiency than regular end-hole catheters in an in vitro model. Diagnostic and Interventional Radiology, Cilt: 26 - Sayı: 6, 565–569. https://ajindex.com/articles/349986

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Kalinowski M, Wagner HJ. Adjunctive techniques in percutaneous mechanical thrombectomy. Tech Vasc Interv Radiol 2003
  2. 6–13. [Crossref] 2. Dopheide JF, Sebastian T, Engelberger RP, Haine A, Kucher N. Early clinical outcomes of a novel rheolytic directional thrombectomy technique for patients with iliofemoral deep vein thrombosis. Vasa 2018
  3. 56–62. [Crossref] 3. Lichtenberg M, Stahlhoff FW, Boese D. Endovascular treatment of acute limb ischemia and proximal deep vein thrombosis using rotational thrombectomy: A review of published literature. Cardiovasc Revasc Med 2013
  4. 343–348. [Crossref] 4. Vedantham S, Goldhaber SZ, Julian JA, et al. ATTRACT Trial Investigators. Pharmacomechanical Catheter-Directed Thrombolysis for Deep-Vein Thrombosis. N Engl J Med 2017
  5. 2240–2252. [Crossref] 5. De Gregorio MA, Guirola JA, Lahuerta C, Serrano C, Figueredo AL, Kuo WT. Interventional radiology treatment for pulmonary embolism. World J Radiol 2017
  6. 295–303. [Crossref] 6. Heller S, Lubanda JC, Varejka P, et al. Percutaneous mechanical thrombectomy using Rotarex® S device in acute limb ischemia in infrainguinal occlusions. Biomed Res Int 2017
  7. 2362769. [Crossref] 7. Zhu QH, Zhou CY, Chen Y, et al. Percutaneous manual aspiration thrombectomy followed by stenting for iliac vein compression syndrome with secondary acute isolated iliofemoral deep vein thrombosis: a prospective study of single-session endovascular protocol. Eur J Vasc Endovasc Surg 2014
  8. 68–74. [Crossref] 8. Kwok CHR, Fleming S, Chan KKC, et al. Aspiration thrombectomy versus conventional catheter-directed thrombolysis as first-line treatment for noniatrogenic acute lower limb ischemia. J Vasc Interv Radiol 2018
  9. 607– 613. [Crossref] 9. Cha JG, Kim CS, Kim HY, Kim HS. Effectiveness of percutaneous aspiration. thrombectomy for acute or subacute thromboembolism in infrainguinal arteries. J Korean Soc Radiol 2017
  10. 386–394. [Crossref] 10. Wagner HJ, Starck EE. Acute embolic occlusions of the infrainguinal arteries: percutaneous aspiration embolectomy in 102 patients. Radiology 1992
  11. 403–407. [Crossref] 11. Wagner HJ, Starck EE, Reuter P. Long-term results of percutaneous aspiration embolectomy. Cardiovasc Intervent Radiol 1994
  12. 241–246. [Crossref] 12. Starck EE, McDermott JC, Crummy AB, Turnipseed WD, Acher CW, Burgess JH. Percutaneous aspiration thromboembolectomy. Radiology 1985
  13. 61–66. [Crossref] 13. Nikoubashman O, Wischer D, Hennemann HM, Büsen M, Brockmann C, Wiesmann M.