AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The average peak spatial head/torso SAR produced by WPT converter is obtained as 0.0254 W/kg, which is lower than recommended restrictions.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:This paper evaluates the performance of a wireless power transfer (WPT) converter for active implantable medical devices (AIMDs).
📊
Key Findings & Data:In the efficiency analyses, the WPT converter is tested by 3D electromagnetic simulation software.
💡
Conclusion & Impact:The average peak spatial head/torso SAR produced by WPT converter is obtained as 0.0254 W/kg, which is lower than recommended restrictions.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Active Medical Device · Efficiency Performance · Wireless Power Transfer

Abstract

This paper evaluates the performance of a wireless power transfer (WPT) converter for active implantable medical devices (AIMDs). The efficiency is the key parameter in the design of a WPT converter for charging of AIMDs. The compensation topology of a WPT system has an important role for high efficiency power transfer. Thus, this work analyses a WPT converter using LC/S hybrid compensation topology, for wireless charging of AIMDs, in terms of high efficiency power transfer. In the efficiency analyses, the WPT converter is tested by 3D electromagnetic simulation software. The maximum efficiency is obtained as 72.33% while the output voltage is 4.2 V and the current is 0.45 A. Finally, safety performance of proposed WPT converter is also evaluated based on specific absorption rate (SAR) analysis. The average peak spatial head/torso SAR produced by WPT converter is obtained as 0.0254 W/kg, which is lower than recommended restrictions.

🔖

Cite This Article

ÇETİN, S., DEMİRCİ, Y. E., BÜYÜKGÜMÜŞ, O. (2020). PERFORMANCE EVALUATION OF A WIRELESS CHARGING CONVERTER FOR ACTIVE IMPLANTABLE MEDICAL DEVICES. Mugla Journal of Science and Technology, Cilt: 6 - Sayı: 2, 11–17. https://ajindex.com/articles/340992

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. CEN EN 45502-1, “Active Implantable Medical Device. Part1: General Requirements for Safety, Marking and Information to be provided by the Manufactures”, 1997
  2. Santini, M., Cappato, R., Andresen, D., Brachmann, J., Davies, D.W., Cleland, J., Filippi, A., Gronda, E., Hauer, R., Steinbeck, G., Steinhaus, D., “Current state of knowledge and experts perspective on the subcutaneous implantable cardioverter-defibrillator,” J. Interventional Cardiac Electrophysiol., Vol. 25: No. 3, 83–88, 2009
  3. Drews, J., Fehrmann, G., Staub, R., and Wolf, R., “Primary batteries for implantable pacemakers and defibrillators”, Journal of Power Sources, Vol. 97–98, 747–749, 2001
  4. Klug, D., Balde, M., Pavin, D., Hidden-Lucet, F., Clementy, J., Sadoul, N., Rey, J.L., Lande, G., Lazarus, A., Victor, J., Barnay, C., Grandbastien, B. and Kacet, S., “Risk Factors Related to Infections of Implanted Pacemakers and Cardioverter-Defibrillators Results of a Large Prospective Study”, Circulation, Vol.116, No.12, 1349-1355, 2007
  5. Campi T., Cruciani S., Palandrani F., De Santis V., Hirata A. and Feliziani M., “Wireless Power Transfer Charging System for AIMDs and Pacemakers”, IEEE Transactions on Microwave Theory and Techniques, Vol.64, No.2, 633- 642, 2016
  6. Lu, Y. and Ki, W.H., “A 13.56 MHz CMOS Active Rectifier With Switched-Offset and Compensated Biasing for Biomedical Wireless Power Transfer Systems”, IEEE Transactions on Biomedical Circuit and Systems, Vol.8, No.3, 334-344, 2014
  7. Ahire, D.B. and Gond, V.J., “Wireless Power Transfer System for Biomedical Application: A Review”, International Conference on Trends in Electronics and Informatics”, 2017, 135-140
  8. Xue, R.F., Cheng, K.W. and Je, M., “High-Efficiency Wireless Power Transfer for Biomedical Implants by Optimal Resonant Load Transformation”, IEEE Transactions on Circuits and Systems - I:Regular Papers, Vol.60, No.4, 867-874, 2013
  9. Yi, Y., Buttner, U., Fan, Y. and Foulds, I.G., “Design and optimization of a 3-coil resonance-based wireless power transfer system for biomedical implants”, International Journal of Circuit Theory and Applications, Vol.43, No.10, 1379–1390, 2015
  10. Rakhyani, A.K.R., Mirabbasi, S. and Chiao, M., “Design and Optimization of Resonance-Based Efficient Wireless Power Delivery Systems for Biomedical Implants”, IEEE Transactions on Biomedical Circuits and Systems, Vol.5, No.1, 48-63, 2011
  11. Cha, H.K., Park, W.T. and Je, M., “A CMOS Rectifier With a Cross-Coupled Latched Comparato