Journals / Ulusal Cerrahi Dergisi / 2014 / Cilt: 30 - Sayı: 4

Tiroid cerrahisinde damar mühürleme cihazı kullanımına genel cerrahların yaklaşımı

The approach of general surgeons to the use of vessel sealing device in thyroid surgery

Pages
197–200
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

However, the observed complication rate was very high

📌 3 Key Takeaways

🎯
Objective & Hypothesis:investigate general surgeons’ approach to the use of VSD in thyroid surgery in Turkey.
📊
Key Findings & Data:Material and Methods: A questionnaire containing 10 items was prepared and announced via the Dialogue in Endocrinology Society website.
💡
Conclusion & Impact:However, the observed complication rate was very high
🔬Design:Survey & Empirical Study
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

investigate general surgeons’ approach to the use of VSD in thyroid surgery in Turkey. Material and Methods: A questionnaire containing 10 items was prepared and announced via the Dialogue in Endocrinology Society website. The results were then analyzed. Results: Fifty surgeons (65.8%) stated that they always use VSD, 20 (26.3%) stated that they sometimes use these devices and six (7.9%) declared that they never use VSD. Thirty-six surgeons (47.4%) reported that they use ligation all the time, and 42 (55.3%) stated that upper pole vessels should be ligated at least once. Twenty two point four percent of the responders stated that they faced a complication, which they thought was related to VSD. Conclusion: The vast majority of surgeons routinely uses VSD and accepts it as a safe tool. However, the observed complication rate was very high

Özet

Amaç: Damar mühürleme cihazları (DMC) tiroid cerrahisinde güvenle kullanılmaktadır. Bu anket çalışmasının amacı Türkiye'de genel cerrahi uzmanlarının tiroid cerrahisinde DMC kullanımı hakkındaki görüşlerini öğrenmektir.Gereç ve Yöntemler: On soruluk bir anket hazırlanarak Endokrinde Diyalog Derneği internet sitesi üzerinden duyuru yapıldı. Alınan sonuçlar analiz edildi.Bulgular: Cerrahların 50'si (%65,8) DMC'nı her zaman kullandığını, 20'si (%26,3) bazen kullandığını, 6'sı (%7,9) ise hiç kullanmadığını belirtti. Cerrahların 36'sı (%47,4) her zaman bağlama yaptığını, 42'si (%55,3) üst pol damarlarının en az bir kere bağlanması gerektiğini bildirdi. Ankete katılanların %22,4'ü DMC ile ilişkili olduğunu düşündüğü bir komplikasyon ile karşılaştığını bildirdi.Sonuç: Cerrahların çok büyük çoğunluğu DMC'nı rutin olarak kullanmakta ve güvenli bir araç olarak görmektedir. Fakat karşılaşılan komplikasyon oranı çok yüksek görülmektedir

🔖

Cite This Article

MAYIR, B., BİLECİK, T., ENSARİ, C. Ö., YARDIMCI, E. C., ORUÇ, M. T. (2014). Tiroid cerrahisinde damar mühürleme cihazı kullanımına genel cerrahların yaklaşımı. Ulusal Cerrahi Dergisi, Cilt: 30 - Sayı: 4, 197–200. https://ajindex.com/articles/325443

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Scalpel to electrocautery in thyroidectomy. Surgery 2005; 137: 337-341. [CrossRef] 2. Koutsoumanis K, Koutras AS, Drimousis PG, Stamou KM, Theodorou D, Katsaragakis S, et al. The use of a harmonic scalpel in thyroid surgery: report of a 3-year experience. Am J Surg 2007; 193: 693-696. [CrossRef] 3. Shemen L. Thyroidectomy using the harmonic scalpel: analysis of 105 consecutive cases. Otolaryngol Head Neck Surg 2002; 127: 284-288. [CrossRef] 4. Miccoli P, Berti P, Dionigi G, D’Agostino J, Orlandini C, Donatini G. Randomized controlled trial of harmonic scalpel use during thyroidectomy. Arch Otolaryngol Head Neck Surg 2006; 132: 1069-1073. [CrossRef] 5. Kilic M, Keskek M, Ertan T, Yoldas O, Bilgin A, Koc M. A prospective randomized trial comparing the harmonic scalpel with conventional knot tying in thyroidectomy. Adv Ther 2007; 24: 632-638. [CrossRef] 6. Ortega J, Sala C, Flor B, Lledo S. Efficacy and cost-effectiveness of the UltraCision harmonic scalpel in thyroid surgery: an analysis of 200 cases in a randomized trial. J Laparoendosc Adv Surg Tech A 2004; 14: 9-12. [CrossRef] 7. Barbaros U, Erbil Y, Bozbora A, Deveci U, Aksakal N, Dinççağ A, et al. The use of LigaSure in patients with hyperthyroidism. Langenbecks Arch Surg 2006; 391: 575-579. [CrossRef] 8. Teksoz S, Bukey Y, Ozcan M, Arikan AE, Ozyegin A. Sutureless thyroidectomy with energy-based devices: Cerrahpasa experience. Updates Surg 2013; 65: 301-307. [CrossRef] 9. Dilek ON, Yilmaz S, Degirmenci B, Ali Sahin D, Akbulut G, Dilek FH. The use of a vessel sealing system in thyroid surgery. Acta Chir Belg 2005; 105: 369-372. 11. Mayir B, Doğan U, Koç Ü, Merter AA, Oruç MT. Life threatening bleeding late after thyroidectomy. Endokrinolojide Diyalog 2013; 10: 142-144. 12. Manouras A, Markogiannakis H, Koutras AS, Antonakis PT, Drimousis P, Lagoudianakis EE, et al. Thyroid surgery: comparison between the electrothermal bipolar vessel sealing system, harmonic scalpel, and classic suture ligation. Am J Surg 2008; 195: 48-52. [CrossRef] 13. Harold KL, Pollinger H, Matthews BD, Kercher KW, Sing RF, Heniford BT. Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries. Surg Endosc 2003; 17: 1228-1230. [CrossRef]