Journals / Ulusal Travma ve Acil Cerrahi Dergisi / 2016 / Cilt: 22 - Sayı: 3

Hemostatic efficacy of local chitosan linear polymer granule in an experimental sheep model with severe bleeding of arteria and vena femoralis

Pages
215–223
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Hemostasis was achieved earlier in the study group, compared to the control group, and the difference was statistically significant.CONCLUSION: Hemostasis was achieved earlier following application of chitosan linear polymer

📌 3 Key Takeaways

🎯
Objective & Hypothesis:BACKGROUND: The aim of the present study was to evaluate the hemostatic effect of chitosan linear polymer in a sheep model with femoral bleeding.METHODS: Following induction of anesthesia and intubation of sheep, groin injury was induced to initiate hemorrhage.
📊
Key Findings & Data:At 5-min intervals, bleeding was evaluated.
💡
Conclusion & Impact:Hemostasis was achieved earlier in the study group, compared to the control group, and the difference was statistically significant.CONCLUSION: Hemostasis was achieved earlier following application of chitosan linear polymer
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

BACKGROUND: The aim of the present study was to evaluate the hemostatic effect of chitosan linear polymer in a sheep model with femoral bleeding.METHODS: Following induction of anesthesia and intubation of sheep, groin injury was induced to initiate hemorrhage. Animals were randomly assigned to study and control groups. In the control group, absorbent pads were packed on the wound, and pressure was supplied by a weight placed over the dressing. In the study group, chitosan linear polymer was poured onto the bleeding site; absorbent pads and pressure were applied in the same manner. At 5-min intervals, bleeding was evaluated. Primary endpoint was time to hemostasis.RESULTS: Bleeding had stopped by the 1st interval in 5 members of the study group, and by the 2nd interval in 1 member. One sheep was excluded. The bleeding stopped after the 1st interval in 1 member of the control group and after the 2nd interval in 4 members. Bleeding stopped in 2 cases following ligation of the bleeding vessel. Hemostasis was achieved earlier in the study group, compared to the control group, and the difference was statistically significant.CONCLUSION: Hemostasis was achieved earlier following application of chitosan linear polymer

🔖

Cite This Article

ERSOY, G., RODOPLU, Ü., YILMAZ, O., GÖKMEN, N., DOĞAN, A., DİKME, Ö., AYDINOĞLU, A., ORHON, O. (2016). Hemostatic efficacy of local chitosan linear polymer granule in an experimental sheep model with severe bleeding of arteria and vena femoralis. Ulusal Travma ve Acil Cerrahi Dergisi, Cilt: 22 - Sayı: 3, 215–223. https://ajindex.com/articles/323770

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Ersoy G, Kaynak MF, Yilmaz O, Rodoplu U, Maltepe F, Gokmen N. Hemostatic effects of microporous polysaccharide hemosphere in a rat model with severe femoral artery bleeding. Adv Ther 2007;24:485–92
  2. Ozgur D, Gurkan E, Osman Y, Ozlem D, Necati G. The Effect of Application of Local Oxidised Cellulose Powder on Hemostasis Time in a Rat Model With Femoral Artery Bleeding. Acta Medica Mediterranea 2015,31:179–82
  3. Aydinoglu A, Ersoy G, Dogan A, Akay H, Yilmaz O, Gokmen N. Hemostatic effect of microporous polysaccharide hemosphere in a heparinized rat model with femoral artery bleeding. European Journal of Emergency Medicine 2008;15:286–306
  4. Eryilmaz M, Ozer T, Menteş O, Torer N, Durusu M, Günal A, et al. Is the zeolite hemostatic agent beneficial in reducing blood loss during arterial injury? Ulus Travma Acil Cerrahi Derg 2009;15:7–11
  5. Eryilmaz M, Mentes O, Ozer MT, Ersoy G, Durusu M, Rodoplu U, et al. Current principles of use of topical hemostatic agents in trauma cases. Turkish Journal of Emergency Medicine 2007;7:136–43
  6. Bulger EM, Snyder D, Schoelles K, Gotschall C, Dawson D, Lang E, et al. An evidence-based prehospital guideline for external hemorrhage control: American College of Surgeons Committee on Trauma. Prehosp Emerg Care 2014;18:163–73
  7. Taillac PP. Stop the bleeding. New external hemorrhage control evidencebased guideline. JEMS 2014;Suppl:18–21
  8. Velmahos GC, Tabbara M, Spaniolas K, Duggan M, Alam HB, Serra M, et al. Self-expanding hemostatic polymer for control of exsanguinating extremity bleeding. J Trauma 2009;66:984–8
  9. Kilbourne M, Keledjian K, Hess JR, Scalea T, Bochicchio GV. Hemostatic efficacy of modified amylopectin powder in a lethal porcine model of extremity arterial injury. Ann Emerg Med 2009;53:804–10
  10. Pusateri AE, Holcomb JB, Kheirabadi BS, Alam HB, Wade CE, Ryan KL. Making sense of the preclinical literature on advanced hemostatic products. J Trauma 2006;60:674–82
  11. Brown MA, Daya MR, Worley JA. Experience with chitosan dressings in a civilian EMS system. J Emerg Med 2009;37:1–7
  12. Recinos G, Inaba K, Dubose J, Demetriades D, Rhee P. Local and systemic hemostatics in trauma: a review. Ulus Travma Acil Cerrahi Derg 2008;14:175–81
  13. Özlem K, Fatma Ö, Betül ÇE, Naciye İB, Deniz S. Hemostatic effect of a chitosan linear polymer (Celox®) in a severe femoral artery bleeding rat model under hypothermia or warfarin therapy. Ulus Travma Acil Cerrahi Derg 2011;17:199–204
  14. Kheirabadi BS, Edens JW, Ter