Journals / Ulusal Travma ve Acil Cerrahi Dergisi / 2019 / Cilt: 25 - Sayı: 5

Acil serviste girişimsel sedasyon ve analjezi uygulanan hastalarda sedasyon derinliğini ölçmede EEG monitörizasyonu (Bispectral IndexTM) ile Ramsey Sedasyon Skalası’nın uyumluluğunun değerlendirilmesi

Evaluation of the compliance between EEG monitoring (Bispectral IndexTM) and Ramsey Sedation Scale to measure the depth of sedation in the patients who underwent procedural sedation and analgesia in the emergency department

Pages
447–452
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

BIS monitörizasyonu, GSA takibinde rutin ve kişi bağımlı klinik skalalara alternatif, objektif bir monitörizasyon yöntemi olarak güvenle kullanılabilir ve komplikasyonları erken tanımada öncül bir gösterge olabilir.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:AMAÇ: Çalışmamızda girişimsel sedasyon ve analjezi uygulanan hastalarda sedasyon derinliğini takip etmede EEG monitörizasyonu (Bispectral Index™, BIS) ile ‘Ramsey Sedasyon Skalası’nın (RSS) uyumluluğunu ve gelişebilecek komplikasyonları tanımada kullanılabilirliğini belirlemeyi amaçladık.
📊
Key Findings & Data:GEREÇ VE YÖNTEM: Çalışmamızda olguların belirli aralıklarla BIS ve RSS değerleri, gelişen komplikasyonlar ve yapılan müdahaleler değerlendirildi.
💡
Conclusion & Impact:BIS monitörizasyonu, GSA takibinde rutin ve kişi bağımlı klinik skalalara alternatif, objektif bir monitörizasyon yöntemi olarak güvenle kullanılabilir ve komplikasyonları erken tanımada öncül bir gösterge olabilir.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

AMAÇ: Çalışmamızda girişimsel sedasyon ve analjezi uygulanan hastalarda sedasyon derinliğini takip etmede EEG monitörizasyonu (Bispectral Index™, BIS) ile ‘Ramsey Sedasyon Skalası’nın (RSS) uyumluluğunu ve gelişebilecek komplikasyonları tanımada kullanılabilirliğini belirlemeyi amaçladık. GEREÇ VE YÖNTEM: Çalışmamızda olguların belirli aralıklarla BIS ve RSS değerleri, gelişen komplikasyonlar ve yapılan müdahaleler değerlendirildi. BIS ve RSS değerlerinin uyumluluğu değerlendirildi. Komplikasyon görülen, görülmeyen olguların BIS değerleri karşılaştırıldı. BULGULAR: Tüm zaman dilimlerindeki BIS ve RSS değerlerinin ortalamaları karşılaştırıldığında aralarında yüksek derecede korelasyon saptandı (r=- 0.989, p<0.001). Komplikasyon görülen olgularda 15. dk’daki BIS değerleri arasında istatistiksel anlamlı bir fark vardı (p=0.018). Olgular BIS değeri <70 ve ≥70 olarak iki gruba ayrıldı. BIS <70 olan grupta daha fazla komplikasyon görüldü (p=0.037). TARTIŞMA: Çalışmamızda RSS ve BIS monitörizasyonu aralarında yüksek derecede korelasyon saptandı. BIS monitörizasyonu, GSA takibinde rutin ve kişi bağımlı klinik skalalara alternatif, objektif bir monitörizasyon yöntemi olarak güvenle kullanılabilir ve komplikasyonları erken tanımada öncül bir gösterge olabilir.

Özet

BACKGROUND: This study aimed to investigate the compliance between electroencephalogram monitoring (Bispectral Index, BIS) and Ramsay Sedation Scale (RSS) to measure the depth of sedation in patients who underwent procedural sedation and analgesia (PSA) in an emergency department. This study also aimed to investigate the usefulness of this compliance for early diagnosis of complications. METHODS: A total of 54 consecutive patients during PSA in the emergency department were included in this study. The BIS and RSS scores at regular intervals and also all complications and interventions of these patients were evaluated. The compliance between the BIS and the RSS score was evaluated. The BIS scores of cases with complication and without complication were compared. RESULTS: The BIS and RSS scores exhibited a high correlation was detected between the average BIS and RSS scores at each time interval (r=-0.989, p<0.001). The BIS scores of the complicated and uncomplicated cases were different at 15 min after the procedure (p=0.019). The cases were divided into two groups according to the BIS scores <70 and ≥70; complication rates were higher in the BIS score <70 group during the procedure (p=0.037). CONCLUSION: In our study, a high correlation was detected between BIS monitoring and RSS scores. BIS monitoring for PSA can be used as a full-time, objective, and an alternative technique for person-dependent clinical scales and also as an indicator for early diagnosis of complications.

🔖

Cite This Article

AVCI, S., BAYRAM, B., İNANÇ, G., GÖREN, N., ÖNİZ, A., ÖZGÖREN, M., ORAY, N. Ç. (2019). Acil serviste girişimsel sedasyon ve analjezi uygulanan hastalarda sedasyon derinliğini ölçmede EEG monitörizasyonu (Bispectral IndexTM) ile Ramsey Sedasyon Skalası’nın uyumluluğunun değerlendirilmesi. Ulusal Travma ve Acil Cerrahi Dergisi, Cilt: 25 - Sayı: 5, 447–452. https://ajindex.com/articles/323573

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. Godwin SA, Burton JH, Gerardo CJ, Hatten BW, Mace SE, Silvers SM, et al
  2. American College of Emergency Physicians. Clinical policy: procedural sedation and analgesia in the emergency department. Ann Emerg Med 2014
  3. 247–58.e18. [CrossRef ] 2. Brown TB, Lovato LM, Parker D. Procedural sedation in the acute care setting. Am Fam Physician 2005
  4. 85–90. 3. Overly FL, Wright RO, Connor FA, Jay GD, Linakis JG. Bispectral anal ysis during deep sedation of pediatric oral surgery patients. J Oral Maxillofac Surg 2005
  5. 215–9. [CrossRef ] 4. Bombacı E, Boztepe A, Çizen A, Çevik B, Çolakoğlu S, Yollu Atakan T. Bilinci kapalı yoğun bakım hastalarında bispektral indeks monitörizasyonu ile modifiye glasgow koma ve ramsay sedasyon skala puanları arasındaki ilişki. Bakırköy Tıp Dergisi 2005
  6. 90–4. 5. De Deyne C, Struys M, Decruyenaere J, Creupelandt J, Hoste E, Colardyn F. Use of continuous bispectral EEG monitoring to assess depth of sedation in ICU patients. Intensive Care Med 1998
  7. 1294–8. [CrossRef ] 6. Robinson BR, Berube M, Barr J, Riker R, Gélinas C. Psychometric analysis of subjective sedation scales in critically ill adults. Crit Care Med 2013
  8. 41(9 Suppl 1):S16–29. [CrossRef ] 7. Weaver CS, Hauter WH, Duncan CE, Brizendine EJ, Cordell WH. An assessment of the association of bispectral index with 2 clinical sedation scales for monitoring depth of procedural sedation. Am J Emerg Med 2007
  9. 918–24. [CrossRef ] 8. Akinci SB, Çelebioglu B. Bispektral indeks monitörizasyonu. Türk Yoğun Bakım Dergisi 2006
  10. 85–90. 9. Fruchter O, Tirosh M, Carmi U, Rosengarten D, Kramer MR. Prospective randomized trial of bispectral index monitoring of sedation depth during flexible bronchoscopy. Respiration 2014
  11. 388–93. [CrossRef ] 10. Jang SY, Park HG, Jung MK, Cho CM, Park SY, Jeon SW, et al. Bispectral index monitoring as an adjunct to nurse-administered combined sedation during endoscopic retrograde cholangiopancreatography. World J Gastroenterol 2012
  12. 6284–9. [CrossRef ] 11. Kocaaslan S, Öniz A, Özgören M. Bispektral indeks ışığında uyku elektrofizyolojisi. Turkiye Klinikleri J Med Sci 2009
  13. 1421–9. 12. Özgören M, Kocaaslan S, Önız A. Analysis of non-REM sleep staging with electroencephalography bispectral index. Sleep and Biological Rhythms 2008
  14. 249–55. [CrossRef ] 13. Ozgoren M, Bayazit O, Kocaaslan S, Gokmen N, Oniz A. Brain function assessment in different conscious states. Nonlinear Biomed Phys 2010
  15. 4 Suppl 1:S6. [CrossRef ] 14. Gill M, Green SM, Krauss B. A