Journals / Ulusal Travma ve Acil Cerrahi Dergisi / 2020 / Cilt: 26 - Sayı: 4

Sürekli infraklaviküler brakial pleksus bloğunda kateter ucu konfigürasyonunun (üç delikliye karşı uçtan delikli) üst ekstremite cerrahisi sonrası analjeziye etkisi

Effects of catheter orifice configuration (triple-hole versus end-hole) in continuous infraclavicular brachial plexus block on analgesia after upper limb surgery

Pages
620–627
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

TARTIŞMA: Infraklavikular sürekli sinir bloğunda MHC kullanımının, ilk 24 saat ameliyat sonrası ağrıyı azaltmada EHC’den daha etkili olduğu sonucuna vardık.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:AMAÇ: Sinir bloğu kateterinin konfigürasyonu epidural analjezi ve sürekli periferik sinir bloklarında lokal anestezik yayılımını etkileyebilmektedir.
📊
Key Findings & Data:Bu ileriye yönelik ve randomize çalışmanın amacı, omuz seviyesinin altında gerçekleştirilen üst ekstremite cerrahilerinde, ultrason rehberliğinde yapılan sürekli infraklaviküler brakiyal pleksus bloğunda (BPB) üç delikli sinir bloğu kateteri ile tek delikli kateterin ameliyat sonrası analjezik etkinliklerini karşılaştırmaktır.
💡
Conclusion & Impact:TARTIŞMA: Infraklavikular sürekli sinir bloğunda MHC kullanımının, ilk 24 saat ameliyat sonrası ağrıyı azaltmada EHC’den daha etkili olduğu sonucuna vardık.
🔬Design:Experimental Field Trial
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

AMAÇ: Sinir bloğu kateterinin konfigürasyonu epidural analjezi ve sürekli periferik sinir bloklarında lokal anestezik yayılımını etkileyebilmektedir. Bu ileriye yönelik ve randomize çalışmanın amacı, omuz seviyesinin altında gerçekleştirilen üst ekstremite cerrahilerinde, ultrason rehberliğinde yapılan sürekli infraklaviküler brakiyal pleksus bloğunda (BPB) üç delikli sinir bloğu kateteri ile tek delikli kateterin ameliyat sonrası analjezik etkinliklerini karşılaştırmaktır. Primer sonuç ölçümleri ortalama ağrı skorlarıydı. Sekonder sonuç ölçümleri, kurtarıcı analjezik tüketimi ve hasta kontrollü analjezi (PCA) cihazı tarafından gönderilen lokal anestezik miktarlarıydı. GEREÇ VE YÖNTEM: Omuz seviyesinin altında üst ekstremite cerrahisi uygulanan toplam 58 erişkin hasta rastgele iki gruba ayrıldı: Tek delikli kateter (EHC) grubu (n=31) ve çok delikli kateter (MOC) grubu (n=27). Tüm hastalara, Tuohy iğnesi ile 100 mg %2 lidokain and 75 mg %0.5 bupivakain ile tek doz infraklaviküler BPB uygulandı. Daha sonra MOC grubuna çok delikli (üç delikli) bir sinir kateteri ve EHC grubuna aynı seviyeden uçtan delikli (tek delikli) kateter yerleştirildi. PCA yoluyla %0.125 bupivakain, kateterlerden infüzyon edildi (infüzyon hızı: 2 ml/sa, otomatik düzenli bolus: 5 ml/sa, hasta kontrollü bolus: 3 ml, kilitleme süresi: 1 saat, 4 saatlik limit: 40 ml). Ağrı şiddeti görsel analog skala (VAS) kullanılarak değerlendirildi. BULGULAR: VAS skorları ameliyat sonrası ilk gün grup EHC’de, grup MOC’den daha yüksekti (p=0.001). Ortalama kurtarma analjezik tüketimi, PCA üzerindeki bolus sayısı, PCA bolus dozu ve toplam PCA dozu, grup EHC’de ameliyat sonrası ilk gün grup MOC’dan daha yüksekti (p<0.05). TARTIŞMA: Infraklavikular sürekli sinir bloğunda MHC kullanımının, ilk 24 saat ameliyat sonrası ağrıyı azaltmada EHC’den daha etkili olduğu sonucuna vardık.

Özet

BACKGROUND: The configuration of a nerve block catheter may affect the local anesthetic spread in epidural analgesia and continuous peripheral nerve blocks. This prospective and randomized study aims to compare the multi-orifice nerve block catheter with an end-hole catheter in ultrasound-guided continuous infraclavicular brachial plexus block (BPB) in terms of providing postoperative analgesia for the orthopedic upper limb surgery below the shoulder. The primary outcome measure was mean pain scores. Secondary outcome measures were the consumption of rescue analgesic and the amount of local anesthetics delivered by a Patient-Controlled Analgesia (PCA) device. METHODS: A total of 58 adult patients who underwent orthopedic upper limb surgery below the shoulder were randomly assigned into two groups: group end-hole catheter (EHC) (n=31) and group multi-orifice catheter (MOC) (n=27). All patients received a single-shot infraclavicular BPB using 100 mg lidocaine 2% and 75 mg bupivacaine 0.5% administrated through a Tuohy needle. Then, a multi–orifice (triple-hole) nerve catheter was placed in the group MOC and an end-hole (one-hole) catheter in the group EHC at the same location. Bupivacaine 0.125% was infused through the catheters via PCA (infusion rate: 2 mlh-1, automated regular bolus: 5 mlh-1, patient-controlled bolus: 3 ml, lock-out time: 1 hour, 4 hours limit: 40 ml). Pain intensity was evaluated using a visual analogue scale (VAS). RESULTS: Mean VAS scores were higher in group EHC than group MOC in the first postoperative day (p=0.001). Mean rescue analgesic consumption, the number of bolus demand on PCA, PCA bolus demand dose, and total PCA dose were higher in group EHC than group MOC during the first postoperative day (p<0.05). CONCLUSION: It is concluded that the use of MHC is more effective than EHC for continuous infraclavicular brachial plexus blocks in providing postoperative pain relief during the first 24 hours.

🔖

Cite This Article

ESKİN, M. B., CEYLAN, A. (2020). Sürekli infraklaviküler brakial pleksus bloğunda kateter ucu konfigürasyonunun (üç delikliye karşı uçtan delikli) üst ekstremite cerrahisi sonrası analjeziye etkisi. Ulusal Travma ve Acil Cerrahi Dergisi, Cilt: 26 - Sayı: 4, 620–627. https://ajindex.com/articles/323424

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Ilfeld BM. Continuous Peripheral Nerve Blocks: An Update of the Published Evidence and Comparison With Novel, Alternative Analgesic Modalities. Anesth Analg 2017;124:308−35
  2. Joshi G, Gandhi K, Shah N, Gadsden J, Corman SL. Peripheral nerve blocks in the management of postoperative pain: challenges and opportunities. J Clin Anesth 2016;35:524−9
  3. Plante T, Rontes O, Bloc S, Delbos A. Spread of local anesthetic during an ultrasound-guided interscalene block: does the injection site influence diffusion?. Acta Anaesthesiol Scand 2011;55:664−9
  4. Fredrickson MJ, Ball CM, Dalgleish AJ. Catheter orifice configuration influences the effectiveness of continuous peripheral nerve blockade. Reg Anesth Pain Med 2011;36:470−5
  5. Segal S, Eappen S, Datta S. Superiority of multi-orifice over single-orifice epidural catheters for labor analgesia and cesarean delivery. J Clin Anesth 1997;9:109−12
  6. Fredrickson MJ. Randomised comparison of an end-hole, triple-hole and novel six-hole catheter for continuous interscalene analgesia. Anaesth Intensive Care 2014;42:37−42
  7. Novello-Siegenthaler A, Hamdani M, Iselin-Chaves I, Fournier R. Ultrasound- guided continuous femoral nerve block: a randomized trial on the influence of femoral nerve catheter orifice configuration (six-hole versus end-hole) on post-operative analgesia after total knee arthroplasty. BMC Anesthesiol 2018;18:191
  8. Fegley AJ, Lerman J, Wissler R. Epidural multiorifice catheters function as single-orifice catheters: an in vitro study. Anesth Analg 2008;107:1079−81
  9. Fredrickson MJ, Abeysekera A, Price DJ, Wong AC. Patient-initiated mandatory boluses for ambulatory continuous interscalene analgesia: an effective strategy for optimizing analgesia and minimizing side-effects. Br J Anaesth 2011;106:239−45
  10. Mariano ER, Sandhu NS, Loland VJ, Bishop ML, Madison SJ, Abrams RA, et al. A randomized comparison of infraclavicular and supraclavicular continuous peripheral nerve blocks for postoperative analgesia. Reg Anesth Pain Med 2011;36:26−31
  11. D’Angelo R, Foss ML, Livesay CH. A comparison of multiport and uniport epidural catheters in laboring patients. Anesth Analg 1997;84:1276−9
  12. Dickson MA, Moores C, McClure JH. Comparison of single, end-holed and multi-orifice extradural catheters when used for continuous infusion of local anaesthetic during labour. Br J Anaesth 1997;79:297−300
  13. NysoRA. Introduction to Ultrasound-Guided Regional Anesthesia. Available from: https://www.nysora.com/founda