Journals / Southern Clinics of Istanbul Eurasia / 2017 / Cilt: 28 - Sayı: 4

Comparison of the Transepicondylar Axis Measured Using Computed Tomography Before Primary Total Knee Arthroplasty and the Surgical Measurement

Pages
278–282
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In the future, measurements made using CT will be used to design personalized anatomical prostheses

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: The purpose of this study was to evaluate the consistency of the angle between the posterior condylar line (PCL) and the transepicondylar axis (TEA) measured during surgery (sTEA) with that of the clinical transepicondylar axis (cTEA) measured using computerized tomography (CT) before primary total knee arthroplasty (TKA).Methods: The records of patients who had undergone primary TKA between 2013 and 2105 and with a preoperative CT measurement of the knee were evaluated.
📊
Key Findings & Data:The angle between the cTEA, or the line joining the most prominent points of the medial and lateral epicondyles, and the PCL was measured using a picture archiving communication system (PACS).Results: The study group consisted of 9 knees of 9 patients (1 male, 8 female; mean age: 67 years, range: 59–80 years).
💡
Conclusion & Impact:In the future, measurements made using CT will be used to design personalized anatomical prostheses
🔬Design:Research Article
📍Scope:2013 Verileri
⚙️Variables:Domain Parameters

Abstract

Objective: The purpose of this study was to evaluate the consistency of the angle between the posterior condylar line (PCL) and the transepicondylar axis (TEA) measured during surgery (sTEA) with that of the clinical transepicondylar axis (cTEA) measured using computerized tomography (CT) before primary total knee arthroplasty (TKA).Methods: The records of patients who had undergone primary TKA between 2013 and 2105 and with a preoperative CT measurement of the knee were evaluated. During surgery, following the distal femoral incision, PCL and sTEA lines were drawn on the surface with a ruler and a pencil and recorded with a digital camera. The angle between the cTEA, or the line joining the most prominent points of the medial and lateral epicondyles, and the PCL was measured using a picture archiving communication system (PACS).Results: The study group consisted of 9 knees of 9 patients (1 male, 8 female; mean age: 67 years, range: 59–80 years). The photographs indicating the angle between the sTEA line and the PCL revealed external rotation in 9 knees (100%), with a mean angle of 2.67±1.41° (range: 1–6°). The preoperative axial CT images also demonstrated external rotation in 9 knees (100%), with a mean angle of 4.67±1.41° (range: 2–7°).Conclusion: There was a difference between the sTEA, which is used to determine the rotation of femoral component during TKA, and the cTEA measured preoperatively using CT. It is safe to use 1 of these 2 techniques to check the result of the other. In the future, measurements made using CT will be used to design personalized anatomical prostheses

🔖

Cite This Article

TAŞDEMİR, Z., BULUT, G., BAYSAL, Ö., ÇEVİK, H. B., ELMALI, N. (2017). Comparison of the Transepicondylar Axis Measured Using Computed Tomography Before Primary Total Knee Arthroplasty and the Surgical Measurement. Southern Clinics of Istanbul Eurasia, Cilt: 28 - Sayı: 4, 278–282. https://ajindex.com/articles/314109

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Akagi M, Matsusue Y, Mata T, Asada Y, Horiguchi M, Iida H, et al. Effect of rotational alignment on patellar tracking in total knee arthroplasty. Clin Orthop Relat Res 1999:155–63
  2. Anouchi YS, Whiteside LA, Kaiser AD, Milliano MT. The effects of axial rotational alignment of the femoral component on knee stability and patellar tracking in total knee arthroplasty demonstrated on autopsy specimens. Clin Orthop Relat Res 1993:170–7
  3. Berger RA, Crossett LS, Jacobs JJ, Rubash HE. Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res 1998:144–53
  4. Moon YW, Seo JG, Lim SJ, Yang JH. Variability in femoral component rotation reference axes measured during navigation-assisted total knee arthroplasty using gap technique. J Arthroplasty 2010;25:238–43
  5. Moreland JR, Bassett LW, Hanker GJ. Radiographic analysis of the axial alignment of the lower extremity. J Bone Joint Surg Am 1987;69:745–9
  6. Hofmann S, Romero J, Roth-Schiffl E, Albrecht T. Rotational malalignment of the components may cause chronic pain or early failure in total knee arthroplasty. Orthopade 2003;32:469–76
  7. Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res 1994:31–43
  8. Berger RA, Rubash HE, Seel MJ, Thompson WH, Crossett LS. Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 1993:40–7
  9. Figgie HE 3rd, Goldberg VM, Figgie MP, Inglis AE, Kelly M, Sobel M. The effect of alignment of the implant on fractures of the patella after condylar total knee arthroplasty. J Bone Joint Surg Am 1989;71:1031–9
  10. Oswald MH, Jakob RP, Schneider E, Hoogewoud HM. Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty 1993;8:419–26
  11. Romero J, Stähelin T, Binkert C, Pfirrmann C, Hodler J, Kessler O. The clinical consequences of flexion gap asymmetry in total knee arthroplasty. J Arthroplasty 2007;22:235–40
  12. Incavo SJ, Wild JJ, Coughlin KM, Beynnon BD. Early revision for component malrotation in total knee arthroplasty. Clin Orthop Relat Res 2007;458:131–6
  13. Whiteside LA, Arima J. The anteroposterior axis for femoral rotational alignment in valgus total knee arthroplasty. Clin Orthop Relat Res 1995:168–72
  14. Insall JN