Journals / Southern Clinics of Istanbul Eurasia / 2021 / Cilt: 32 - Sayı: 1

Clinical Results of Nitinol Plate Implantation for Reconstruction of Sternal Dehiscence

Pages
30–35
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The use of TRNCs for patients with sternal dehiscence was successful and decreased the duration of hospital stay and the risk of postoperative complications, as well as providing greater patient comfort.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: Difficulties with sternal bone healing or infection after a median sternotomy performed for open cardiac surgery can result in significant morbidity and mortality.
📊
Key Findings & Data:Methods: TRNCs were used to close the sternum in 40 patients (26 male, 14 female; mean age: 60±4 years, range: 45–76 years) with sternal dehiscence that developed following primary cardiac surgery between July 2010 and February 2019.
💡
Conclusion & Impact:The use of TRNCs for patients with sternal dehiscence was successful and decreased the duration of hospital stay and the risk of postoperative complications, as well as providing greater patient comfort.
🔬Design:Research Article
📍Scope:2010 Verileri
⚙️Variables:Domain Parameters

Özet

Objective: Difficulties with sternal bone healing or infection after a median sternotomy performed for open cardiac surgery can result in significant morbidity and mortality. This study evaluates the efficacy, safety, advantages, disadvantages, and techniques related to the use of thermoreactive nitinol clips (TRNCs) to treat sternal dehiscence. Methods: TRNCs were used to close the sternum in 40 patients (26 male, 14 female; mean age: 60±4 years, range: 45–76 years) with sternal dehiscence that developed following primary cardiac surgery between July 2010 and February 2019. Sternum revision was performed at a mean of 72±4 days postoperative (range: 9–255 days). Vacuum-assisted closure (VAC) was applied before the surgical intervention in 55% (n=22) of the patients due to superficial wound infection. Results: Pleurisy was observed in 1 patient, and pneumonia developed in 1 patient after the revision. Mortality did not occur during hospitalization. The nitinol plates were removed in a second revision surgery in 9 patients: a pectoralis flap was created for 3, a reconstructive rectus flap was used in 1, and primary wound closure was implemented in 5 cases due to recurrent wound infection. Mortality was recorded in 1 patient in the postoperative period. Sternotomy complications of recurrent sternal dehiscence, mediastinitis, sternal abscess, or secondary osteomyelitis were not observed in 6 months of follow-up. Conclusion: Surgical interventions for sternal dehiscence should optimally be performed in the early period to decrease the risk of dehiscence secondary to infection and mediastinitis. The use of TRNCs for patients with sternal dehiscence was successful and decreased the duration of hospital stay and the risk of postoperative complications, as well as providing greater patient comfort.

🔖

Cite This Article

APAYDIN, T., AKKUŞ, M. (2021). Clinical Results of Nitinol Plate Implantation for Reconstruction of Sternal Dehiscence. Southern Clinics of Istanbul Eurasia, Cilt: 32 - Sayı: 1, 30–35. https://ajindex.com/articles/313999

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Sarıkaya S, Büyükbayrak F, Altaş Ö, Yerlikhan O, Fedakar A, Rabuş M, et al. Thermoreactive nitinol clips for re-sternotomy in cases of sternal dehiscence. Turk Gogus Kalp Dama 2013;21:669–75
  2. Sahasrabudhe P, Jagtap R, Waykole P, Panse N, Bhargava P, Patwardhan S. Our experience with pectoralis major flap for management of sternal dehiscence: A review of 25 cases. Indian J Plast Surg 2011;44:405–13
  3. Fawzy H, Osei-Tutu K, Errett L, Latter D, Bonneau D, Musgrave M, et al. Sternal plate fixation for sternal wound reconstruction: initial experience (Retrospective study). J Cardiothorac Surg 2011;6:63
  4. Karaca K, Mavioğlu, Karaca K. Açık Kalp Cerrahisi Sonrasında Gelişen Sternal Dehisensin Titanyum Mesh ile Onarımı. Turkiye Klinikleri J Cardiovasc Sci 2008;20:222–4
  5. Gad M, Gupta A. Dancing sternal wires: A radiologic sign of sternal dehiscence. Clevel Clin J Med 2019;86:87–8
  6. Gucu A, Toktaş F, Eriş C, Ata Y, Turk T. Nitinol Thermoreactive Clips for Secondary Sternal Closure in Cases of Noninfective Sternal Dehiscence. Tex Heart Inst J 2012;39;513–6
  7. Hayward RH, Knight WL, Baisden CE, Reiter CG. Sternal Dehiscence. J Thorac Cardiovasc Surg 1994;108:616–9
  8. Raman J, Lehmann S, Zehr K, Guzman B.J.D, Aklog L, Garrett E, et al. Sternal Closure With Rigid Plate Fixation Versus Wire Closure: A Randomized Controlled Multicenter Trial. Ann Thorac Surg 2012;94:1854–61
  9. Eisenberg E, Pultorak Y, Pud D, Bar-El Y. Prevalence and characteristics of post coronary artery by pass graft surgery pain. Pain 2001;92:11–7
  10. Kalso E, Mennander S, Tasmuth T, Nilsson E. Chronic post sternotomy pain. Acta Anaethesiol Scand 2001;45:935–9
  11. Taillefer MC, Carrier M, Bélisle S, Levesque S, Lanctôt H, Boisvert AM, et al. Prevalence,characteristics and predictors of chronic nonanginal postoperative pain after cardiac operation: a cross sectional study. J Thoracic Cardiovasc Surg 2006;131:1274–80
  12. Sarıkaya S, Aksoy E, Özen Y, Dedemoğlu M, Özgür MM, Büyükbayrak F, et al. Thermoreactive nitinol clips: propensity score comparison with Robicsek technique. Asian Cardiovasc Thorac Ann 2015;23;399–405
  13. Bejko J, Bottio T, Tarzia V, De Franceschi M, Bianco R, Gallo M, et al. Nitinol flexigrip sternal closure system and standard sternal steel rewiring: insight from a matched comparative analysis. J Cardiovasc Med (Hagerstown) 2015;23:399–405
  14. Şahin M, El H, Mert FTİ. Comparison of three different sternal closure techniques after cardiac surgery in elderly patient