Journals / Su Ürünleri Dergisi / 2020 / Cilt: 37 - Sayı: 3

The role and importance of photonic sensors in seafood safety applications

Fotonik sensörlerin su ürünleri gıda güvenliği uygulamalarındaki rolü ve önemi

Pages
319–324
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In this study, optical sensors and their applications are emphasized and a general evaluation is made about the usability of seafood processing technology in terms of food safety.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Microbiological, chemical, sensory analyses known as traditional methods are used for determination of fish quality including many concepts such as microbiological quality, sensory quality, nutritional properties, product specific properties, freshness, species-specific physical properties.
📊
Key Findings & Data:With the developing technology; these time-consuming and error-free analyzes have been replaced by sensor technology, which is very suitable for quality measurements in order to achieve the expected speed and high standard and to be open to improvement.
💡
Conclusion & Impact:In this study, optical sensors and their applications are emphasized and a general evaluation is made about the usability of seafood processing technology in terms of food safety.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Microbiological, chemical, sensory analyses known as traditional methods are used for determination of fish quality including many concepts such as microbiological quality, sensory quality, nutritional properties, product specific properties, freshness, species-specific physical properties. With the developing technology; these time-consuming and error-free analyzes have been replaced by sensor technology, which is very suitable for quality measurements in order to achieve the expected speed and high standard and to be open to improvement. In this study, optical sensors and their applications are emphasized and a general evaluation is made about the usability of seafood processing technology in terms of food safety.

Özet

: Mikrobiyolojik kalite, duyusal kalite, besleyici özellikler, ürüne özgü özellikler, tazelik, türlere özgü fiziksel özellikler gibi birçok kavramı içeren balık kalitesinin tespiti için mikrobiyolojik, kimyasal ve duyusal analizler gibi geleneksel yöntemler kullanılmaktadır. Gelişen teknoloji ile oldukça zaman alan ve hata payına sahip bu geleneksel analiz yöntemlerinin yerini, daha hızlı ve güvenilir kalite ölçümleri yapmayı sağlayan ve gelişime açık sensör teknolojisi almaya başlamıştır. Bu çalışmada, özellikle optik sensörler ve kullanım alanları üzerinde durulmuş ve su ürünleri işleme teknolojisi gıda güvenliği açısından kullanılabilirlikleri hakkında genel bir değerlendirme yapılmaya çalışılmıştır.

🔖

Cite This Article

DUMAN, E., ALTINELATAMAN, C., TOKAÇ, A. (2020). The role and importance of photonic sensors in seafood safety applications. Su Ürünleri Dergisi, Cilt: 37 - Sayı: 3, 319–324. https://ajindex.com/articles/311159

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (5)

  1. Akyol, V., Kundakçı, A. & Ergönül, B. (2015). Gıdalarda Biyojen Aminler. Celal Bayar Üniversitesi Fen Bilimleri Dergisi, 11, 294-305. DOI: 10.18466/cbujos.89924 Arda, M., Seçer, S. & Sarıeyyüpoğlu, M. (2005). Balık Hastalıkları. Ankara. Medisan Yayın Serisi: 61. Areed, N.F.F., Hameed, M.F.O. & Obayya, S.S.A. (2017). Highly sensitive face-shaped label-free photonic crystal refractometer for glucose concentration monitoring. Optical and Quantum Electronics, 49(5). DOI: 10.1007/s11082-016-0847-9
  2. Atiqullah, S.M., Palit, A., Reja, M.I., Akhtar, J., Fatema, S. & Absar, R. (2019). Detection of harmful food additives using highly sensitive photonic crystal fiber. Sensing and Bio-Sensing Research, 23. DOI: 10.1016/j.sbsr.2019.100275 Ayyub, O.B., Ibrahim, M.B., Briber, R.M. & Kofinas, P. (2013). Self-assembled block copolymer photonic crystal for selective fructose detection. Biosensors and Bioelectronics, 46, 124–129. DOI: 10.1016/j.bios.2013.02.025 Borisov, S.M. & Wolfbeis, O.S. (2008). Optical Biosensors. Chemical Reviews, 108, 423–461. DOI: 10.1021/cr068105t Cheng, J.H., Sun, D.W., Zeng, X.A. & Liu, D. (2015). Recent advances in methods and techniques for freshness quality determination and evaluation of fish and fish fillets: a review. Critical Reviews in Food Science and Nutrition, 55, 1012-1225. DOI: 10.1080/10408398.2013.769934 Chow, E., Lin, S.Y., Wendt, J.R., Johnson, S.G. & Joannopoulos, J.D. (2001). Quantitative analysis of bending efficiency in photonic-crystal waveguide bends at λ = 1.55 μm wavelengths. Optics Letters, 26, 286 – 288. DOI: 10.1364/OL.26.000286 Dürüst, N., Naç, S. & Ünal, N. (2010). Poliiyon-Duyarlı Polimer Bazlı Optik Sensörler Kullanılarak Bazı Gıda Ürünlerindeki Kıvam Arttırıcı Katkı Maddelerinin Kantitatif Tayinleri. 24. Ulusal Kimya Kongresi 2010.
  3. Zonguldak, Türkiye: Bildiri Kitabı. Erkmen, O. & Bozoglu, T. (2016). Spoilage of fish and other seafoods. Food Microbiology: Principles into Practice (pp 301-306). John Wiley & Sons, Ltd. DOI:10.1002/9781119237860 Gnaiger, E. & Fortsner, H. (1983). Polarographic oxygen sensors. Aquatic and physiological applications. Springer-Verlag, Berlin. DOI: 10.1007/978-3-642-81863-9
  4. Gök, V., Batu, A. & Telli, R. (2006). Akıllı paketleme teknolojisi. Türkiye 9.Gıda Kongresi 2006. (pp. 45-48)
  5. Bolu, Türkiye: Bildiri Kitabı. Halasz, A., Barath, A., Sarkadi, L.S. & Holzapfel, W. (1994). Biogenic amines and their production by mikroorganism in food. Trend. Food Science and Technology, 5, 42-49. DOI: 10.101