Journals / Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi / 2019 / Cilt: 23 - Sayı: 0

Ground and Structural Interaction Using Geophysical Methods

Jeofizik Yöntemler ile Yer ve Yapı Etkileşimi

Pages
46–60
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

As a result, amplitude amplification of the earthquake waves passing from the ground to the building depending on the earthquake magnitude and distance was obtained between 6 and 12.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, it was investigated the amplification effect and dominant frequencies of the earthquake waves, in the 5-floors building and the ground where was built it.
📊
Key Findings & Data:With this purpose, accelerometers were placed on the roof and ground of the 5-floors building in 2008.
💡
Conclusion & Impact:As a result, amplitude amplification of the earthquake waves passing from the ground to the building depending on the earthquake magnitude and distance was obtained between 6 and 12.
🔬Design:Research Article
📍Scope:2008 Verileri
⚙️Variables:Deprem · Büyütme · İvmeölçer

Abstract

In this study, it was investigated the amplification effect and dominant frequencies of the earthquake waves, in the 5-floors building and the ground where was built it. With this purpose, accelerometers were placed on the roof and ground of the 5-floors building in 2008. In order to determine the ground class, the MASW measure was taken, shear wave velocity (Vs30)was calculated for the first 30 m. Accelerometers that were placed in the building and the ground recorded earthquakes with moment magnitude of 3, 4, 5 and 6 at close and far distances from different sources. Spectral ratio technique and horizontal / vertical spectral ratio technique have been applied to earthquake signals depending on the reference method and single station method in order to obtain the amplification of the building and the ground. As a result of the application of these techniques, the resonance conditions, the dominant frequencies, and the amplifications which belong to building and ground were investigated. As a result, amplitude amplification of the earthquake waves passing from the ground to the building depending on the earthquake magnitude and distance was obtained between 6 and 12.

Özet

Bu çalışmada 5 katlı bir yapının ve yerin deprem dalgalarını büyütme etkisi ve baskın frekansları araştırılmıştır. Bu amaçla 2008 yılında 5 katlı yapının çatısına ve yapının inşa edildiği yere ivmeölçer aygıtları yerleştirilmiştir. Yer sınıfının belirlenmesi amacıyla MASW ölçüsü alınmış, yerin ilk 30 m için makaslama (kayma) dalgası hızı (Vs30) hesaplanmıştır. Bina ve yere yerleştirilen ivmeölçerler kullanılarak moment büyüklüğü 3, 4, 5 ve 6 olan, farklı kaynaklardan yakın ve uzak mesafede birçok deprem kaydedilmiştir. Yapının ve yerin büyütmesini elde edebilmek için kaydedilen deprem sinyallerine referans yöntemine göre spektral oran ve tek istasyon yöntemine göre yatay/düşey oran teknikleri uygulanmıştır. Bu tekniklerin uygulanması sonucunda binaya ve yere ait büyütmeler, baskın frekanslar ve binanın sönüm oranı belirlenmiş, bina ve yerin girişim durumu incelenmiştir. Sonuç olarak yerden binaya geçen deprem dalgalarının genlik büyütmesi deprem büyüklüğüne ve uzaklığına bağlı olarak 6-12 aralıkta elde edilmiştir.

🔖

Cite This Article

ATEŞ, E., UYANIK, O. (2019). Ground and Structural Interaction Using Geophysical Methods. Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi, Cilt: 23 - Sayı: 0, 46–60. https://ajindex.com/articles/309858

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. Irikura, K., Iwata, T., Sekiguchi, H., and Pitarka, A.,1996. Lessons from the 1995 Hyogo-Ken Nanbu earthquake: why where such destructive motions generated to buildings? Journal of Natural Disaster Science, 17(2), 99-127
  2. Borcherdt R. D., 1970. Effects of Local Geology on Ground Motion Near San Francisco Bay. Bulletin of The Seismological Society of America, 60, 29-61
  3. Steidl J. H., Tumarkin A. G., Archuleta R. J., 1996. What is a reference site?. Bull Seism. Soc. Am., 86, 1733-1748
  4. Nakamura Y., 1989. A Method for Dynamic Characteristics Estimation of Subsurface Using Microtremor on the Ground Surface. Quarterly Report of the Railway Technical Research Institute, 30(1), 25-33
  5. Lermo J., Chavez G. F. J., 1993. Site Effect Evaluation Using Spectral Ratios with Only One Station. Bulletin Seismological Society of America, 83, 1574–1594
  6. Yalçınkaya,E., Alptekin,Ö., 2003. Dinar’da zemin büyütmesi ve 1 Ekim 1995 depreminde gözlenen hasarla ilişkisi. Hacettepe Üniversitesi, Yerbilimleri Uygulama ve Araştırma Merkezi Bülteni,27,1-13
  7. Gök E., Keçecioğlu M., Çeken U., Polat O., 2012. İzmirnet İstasyonlarında Standart Spektral Oran Yöntemi Kullanılarak Zemin Transfer Fonksiyonlarının Hesaplanması. Dokuz Eylül Üniversitesi, Mühendislik Fakültesi, Mühendislik Bilimleri Dergisi, 14(41), 1-11
  8. Uyanık O., Çatlıoğlu B., Uyanık NA., Öncü Z., Sabbağ N., 2012a. Kentsel Dönüşüm Projelerinde Betonarme Yapıların Beton Kalitesinin Sismik Ultrasonik Hızlardan Belirlenmesi. 1.Yerbilimleri Sempozyumu, 18-20 Ekim, Isparta, 147-151
  9. Uyanık O., Sabbağ N., Çatlıoğlu B., Uyanık NA., Öncü Z., 2012b. Sismik Ultrasonik Hızlardan Kayaçların Kırıklılık Ve Fissür İndekslerinin Belirlenmesi
  10. Yerbilimleri Sempozyumu, 18-20 Ekim, Isparta, 159-164
  11. Uyanık O., Çatlıoğlu B., Sabbağ N., Öncü Z., Uyanık NA., 2012c. Kayaçların Fiziksel Özellikleri İle Sismik Ultrasonik Hızlar Arasındaki İlişkilendirmeler
  12. Yerbilimleri Sempozyumu, Isparta, 165-169
  13. Sabbağ N., Uyanık O., 2017. Prediction of Reinforced Concrete Strength by Ultrasonic Velocities. Journal of Applied Geophysics, 141, 13-23
  14. Sabbağ, N., Uyanık, O, 2018. Determination of the reinforced concrete strength by electrical resistivity depending on the curing conditions, Journal of Applied Geophysics, 155, 13-25
  15. Karabulut, S., Ozel O., Özçep F., 2009. Deprem Tehtidi Altındaki Mühendislik Yapılarının Hakim Titreşim Periyotlarının Belirlenmesinde Yeni Bir Seçenek: Mikrotremor Yöntemi Ve Örn