Journals / Politeknik Dergisi / 2018 / Cilt: 21 - Sayı: 2

Investigation of Electrical Resistivity of Cement Paste Blended with Blast Furnace Slag

Yüksek Fırın Cüruf Katkılı Çimento Pastalarının Elektriksel Özdirençlerinin Araştırılması

Pages
257–264
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

As a result, adding blast furnace slag at a high proportion and application of electrical current to the cement pastes shorten the setting time.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, the effects of blast furnace slag content and water/cement ratio at cement pastes on the electrical resistivity were investigated.
📊
Key Findings & Data:The blast furnace slag was used in the admixtures by replacing the cement in ratio of 0%, 10%, 20% and 30% by weight.
💡
Conclusion & Impact:As a result, adding blast furnace slag at a high proportion and application of electrical current to the cement pastes shorten the setting time.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Beton bileşen · çimento pastası · elektriksel öz direnç

Abstract

In this study, the effects of blast furnace slag content and water/cement ratio at cement pastes on the electrical resistivity were investigated. Admixtures having different water/cement ratios and admixtures having binder at different dosage levels were prepared. The blast furnace slag was used in the admixtures by replacing the cement in ratio of 0%, 10%, 20% and 30% by weight. Electrical current was applied to the fresh cement pastes in the molds. The measurements were done at room temperature. The differences between electrical resistivity and hydration time with and without electric current application on the specimens were investigated. As a result, adding blast furnace slag at a high proportion and application of electrical current to the cement pastes shorten the setting time.

Özet

Bu çalışmada çimento pastalarında yüksek fırın cürufu içeriği ve su/çimento oranının elektriksel öz direnç üzerindeki etkisi araştırılmıştır. Farklı su/çimento oranlarında ve farklı oranda bağlayıcı içeren karışımlar hazırlanmıştır. Karışımlarda çimento yerine ağırlıkça %0, %10, %20, %30 oranlarında yüksek fırın cürufu konulmuştur. Taze haldeki çimento pastalarına kalıp içerisinde elektrik akımı uygulanmış, ölçümler oda sıcaklığında yapılmıştır. Elektrik akımı uygulanmış ve elektrik akımı uygulanmamış numunelerdeki hidratasyon zamanı ile elektriksel öz direnç arasındaki farklar araştırılmıştır. Sonuç olarak, çimento pastalarına yüksek oranda yüksek fırın cürufu konulması ve elektrik akımı uygulanması ile priz süresi kısalmaktadır.

🔖

Cite This Article

TOPÇU, İ. B., UYGUNOĞLU, T., HOCAOĞLU, İ. (2018). Investigation of Electrical Resistivity of Cement Paste Blended with Blast Furnace Slag. Politeknik Dergisi, Cilt: 21 - Sayı: 2, 257–264. https://ajindex.com/articles/307386

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (16)

  1. Öner A., Yıldırım T. “Öğütülmüş yüksek fırın cürufu içeren ve içermeyen betonlarda kırmataş kumu içeriğinin beton özeliklerine etkisi”, Deprem Sempozyumu Kocaeli, Kocaeli, (2005)
  2. Tokyay M., Erdoğdu K., “Cüruflar ve curuflu çimentolar”, Türkiye Çimento Müstahsilleri Birliği, Ankara, (2002)
  3. ACI 233.R-95, “Ground granulated blast-furnace slag as a cementitious constituent in concrete reported by ACI committe 233, American Concrete Institude, Detroit, Michigan
  4. Morsy M.S., “Effect of temperature on electrical conductivity of blended cement pastes”, Cem Concr Res, 29: 603-606, (1999)
  5. Yio M.H.N., Phelan J.C., Wong H.S., Buenfeld N.R., “Determining the slag fraction,water/binder ratio and degree of hydration in hardened cement pastes”, Cement and Concrete Research, 56: 171–181, (2014)
  6. Backe K.R., Lile O.B. Lyomov,S.K., “Characterizing curing cement slurries by electrical conductivity”, SPE Drilling & Completion, 201-207, (2001)
  7. Whittington H.W., McCart J., Forde M.C., “The conduction of electricity through concrete”, Mag Concr Res, 33: 48-60, (1981)
  8. Xiao L., Li Z., Wei X., “Selection of superplasticizer in concrete mix design by measuring the early electrical resistivities of pastes”, Cem Concr Comp, 29: 350-356, (2007)
  9. Schwarz N., DuBois M., Neithalath N., “Electrical conductivity based characterization of plain and coarse glass powder modified cement pastes”, Cem Concr Comp, 29: 656-666, (2007)
  10. Wei X., Li Z., “Early hydration process of portland cement paste by electrical measurement”, J Mater Civ Eng, 18, 1: 99-105, (2006)
  11. Buenfeld N.R. Newman J.B.,” Examination of three methods for studying ion diffusion in cement pastes”, Mortars and Concrete. Mater Struc, 20: 3-10, (1987)
  12. Li Z., Xiao,L., Wei X., “Determination of concrete setting time using electrical resistivity measurement”, Journal of Mater Civ Eng, 19, 5: 423-427, (2007)
  13. Levita G., Marchetti A., Gallone G., Princigallo A., Guerrini G.L., “Electrical properties of fluidified portland cement mixes in the early stage of hydration”, Cem Concr Res, 30: 923-930, (2000)
  14. Rajabipour F., Weiss J., “Electrical conductivity of drying cement paste”, Mater Struc, 40: 1143-1160, (2007)
  15. Koleva D.A., Copuroglu O., Breugel K.V., Ye G., Wit J.H.W. de., “Electrical resistivity and microstructural properties of concrete materials in conditions of current flow”, Cem Concr Comp, 30: 731-744, (2008)
  16. Xiao L., Li Z., “Early-age hydration of fres