Journals / Politeknik Dergisi / 2021 / Cilt: 24 - Sayı: 2

Curve/Probabilistic Fitting of Damage Metrics for Al-7075 Materials Behavior by Using Electromechanical Impedance Method

Pages
481–494
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The experimental results analyzed using a curve/probabilistic fitting approach

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The purpose of structural health monitoring is to provide information by making a simultaneous diagnosis of the status of the structure.
📊
Key Findings & Data:Therefore, the real cause of the change can be determined.In this study, the behavior of constrained piezoelectric wafer active sensor (PWAS)/Al 7075 was investigated by using electromechanical impedance method (EMI) under changing environmental conditions.
💡
Conclusion & Impact:The experimental results analyzed using a curve/probabilistic fitting approach
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Structural health monitoring · piezoelectric sensors · electromechanical impedance method

Abstract

The purpose of structural health monitoring is to provide information by making a simultaneous diagnosis of the status of the structure. Despite aging, environmental conditions and unforeseen circumstances, the construction should remain as specified in the design. Changing the environmental conditions causes the sensor and the host structure to change material properties. It is essential to take into account environmental conditions to prevent misdiagnosis. Therefore, the real cause of the change can be determined.In this study, the behavior of constrained piezoelectric wafer active sensor (PWAS)/Al 7075 was investigated by using electromechanical impedance method (EMI) under changing environmental conditions. Numerical studies on this material in the literature are limited and all the experimental/ numerical results are compensated for the temperature effect and analyzed using curve/probabilistic fitting approach for the first time. The sample used in the experimental work was modeled in ANSYS finite element program. In the experimental and numerical results, it has been observed that as the temperature decreases, the frequency shifts to the right and the amplitude increases. The experimental and simulation results were nearly the same. The temperature effect was compensated using the compensation algorithm for experimental and numerical studies. The results were compared using damage metrics. The experimental results analyzed using a curve/probabilistic fitting approach

Özet

The purpose of structural health monitoring is to provide information by making a simultaneous diagnosis of the status of the structure. Despite aging, environmental conditions and unforeseen circumstances, the construction should remain as specified in the design. Changing the environmental conditions causes the sensor and the host structure to change material properties. It is essential to take into account environmental conditions to prevent misdiagnosis. Therefore, the real cause of the change can be determined.In this study, the behavior of constrained piezoelectric wafer active sensor (PWAS)/Al 7075 was investigated by using electromechanical impedance method (EMI) under changing environmental conditions. Numerical studies on this material in the literature are limited and all the experimental/ numerical results are compensated for the temperature effect and analyzed using curve/probabilistic fitting approach for the first time. The sample used in the experimental work was modeled in ANSYS finite element program. In the experimental and numerical results, it has been observed that as the temperature decreases, the frequency shifts to the right and the amplitude increases. The experimental and simulation results were nearly the same. The temperature effect was compensated using the compensation algorithm for experimental and numerical studies. The results were compared using damage metrics. The experimental results analyzed using a curve/probabilistic fitting approach

🔖

Cite This Article

HAYDARLAR, G., TEKKALMAZ, M., SOFUOĞLU, M. A. (2021). Curve/Probabilistic Fitting of Damage Metrics for Al-7075 Materials Behavior by Using Electromechanical Impedance Method. Politeknik Dergisi, Cilt: 24 - Sayı: 2, 481–494. https://ajindex.com/articles/307013

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (8)

  1. Aktan, A. E., Helmicki, A. J., Hunt, V. J., 1998, Issues in health monitoring for intelligent infrastructure, Smart Materials and Structures, 7(5), 674-692.
  2. Amezquita-Sanchez, J., Valtierra-Rodriguez, M., Aldwaik, M., Adeli, H., 2016, Neurocomputing in Civil Infrastructure, Scientia Iranica, 23(6), pp. 2417-2428. APC International Ltd. Product Manual- Piezoelectric Ceramic: Principles and Applications, 2006, http://www.americampiezo.com
  3. Baptista, F. G., Budoya, D. E., de Almeida, V. A., Ulson, J. A., 2014, An experimental study on the effect of temperature on piezoelectric sensors for impedance-based structural health monitoring, Sensors (Basel), 14(1), 1208-1227.
  4. Bukhari, S., Islam, M., Haziot, A., Beamish, J., 2014, Shear piezoelectric coefficients of PZT, LiNbO3and PMN-PT at cryogenic temperatures, Journal of Physics: Conference Series, 568(3). Choi, K., Chang, F.-K., 1996, Identification of impact force and location using distributed sensors, AIAA Journal, 34(1), 136-142.
  5. Doebling, S. W., Farrar, C. R., Prime, M. B., 1998, A summary review of vibration-based damage identification methods, The Shock and Vibration Digest, 30(2), 91-105.
  6. Fallahian, S., Joghataie, A., Kazemi, M., 2017, Structural damage detection using time domain responses and teaching–learning-based optimization (TLBO) algorithm, Scientia Iranica, (article in press),doi: 10.24200/sci.2017.4238 Freitas, V. F., Santos, I. A., Botero, É., Fraygola, B. M., Garcia, D., Eiras, J. A., 2011, Piezoelectric Characterization of (0.6)BiFeO3-(0.4)PbTiO3 Multiferroic Ceramics, Journal of the American Ceramic Society, 94(3), 754-758.
  7. Goldberg, D.E., 1989, Genetic algorithms in search, optimization, and machine learning. Reading, Mass: Addison-Wesley Pub. Co. Grisso, B. L., Inman, D. J., 2010, Temperature corrected sensor diagnostics for impedance-based SHM, Journal of Sound and Vibration, 329(12), 2323-2336.
  8. Gupta, V., Sharma, M., Thakur, N., Singh, S. P., 2011, Active vibration control of a smart plate using a piezoelectric sensor–actuator pair at elevated temperatures, Smart Materials and Structures, 20(10). Haider, M. F., Giurgiutiu, V., Lin, B., Yu, L., 2017, Irreversibility effects in piezoelectric wafer active sensors after exposure to high temperature, Smart Materials and Structures, 26(9). Hooker, M. W., 1998, Properties of PZT-based Piezoelectric Ceramics between 150 and 250 °C. Technical Report, National Aeronautics and Space Administration. Imaoka, S, 1999, Ansys tip of the week: Conversion