Journals / Politeknik Dergisi / 2017 / Cilt: 20 - Sayı: 4

Hydroxyapatite Coating on Ti6Al4V Alloy Surface Through Biomimetic Method Using Glycolic Acid - Sodium Gluconate Buffer System and Examination of Properties of the Coating

Pages
992–1001
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Additionally, the presence of HA crystals with intense phase structure, with compact and homogeneous distribution on the substrate have been observed.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The use of implant materials is one of the important surgical interventions in the treatment of disorders that are congenital and acquired deformities in musculoskeletal system.
📊
Key Findings & Data:In the implantation process, the surfaces of these alloys are coated with ceramic based biomaterials to increase the bioactivity and biocompatibility properties.
💡
Conclusion & Impact:Additionally, the presence of HA crystals with intense phase structure, with compact and homogeneous distribution on the substrate have been observed.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Biomimetic coating · glycolic acid - sodium gluconate · Hydroxyapatite (HA)

Özet

The use of implant materials is one of the important surgical interventions in the treatment of disorders that are congenital and acquired deformities in musculoskeletal system. Metallic biomaterials within these implant materials are often preferred because of their proximity to the mechanical properties of the bone. In the implantation process, the surfaces of these alloys are coated with ceramic based biomaterials to increase the bioactivity and biocompatibility properties. In this study, it is aimed to create hydroxyapatite (HA) coating that is completely harmonious with human blood plasma environment, on Ti6Al4V alloy, using glycolic acid - sodium gluconate buffer system with biomimetic method for the first time in literature. Coating was realised inside synthetic body fluid (SBF) with waiting periods of 24, 48, 72 and 96 hours. Relating to the coatings, surface smoothness and thickness specifications have been determined, their micro structure has been analysed by Scanning Electron Microscope (SEM), the elementary analyses namely Energy Dispersive X-ray Spectroscopy (EDS) for the surfaces of coating have been determined and X-Ray Diffraction (XRD) analysis have been conducted for obtaining the concentrations of the phases. As a result of the experiments, successful surface smoothness values and ratio of Ca/P close to optimal value have been obtained. Additionally, the presence of HA crystals with intense phase structure, with compact and homogeneous distribution on the substrate have been observed.

🔖

Cite This Article

AYDIN, İ., ENGİN, F. (2017). Hydroxyapatite Coating on Ti6Al4V Alloy Surface Through Biomimetic Method Using Glycolic Acid - Sodium Gluconate Buffer System and Examination of Properties of the Coating. Politeknik Dergisi, Cilt: 20 - Sayı: 4, 992–1001. https://ajindex.com/articles/306570

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Özkurt B. and Tabak A. Y., “Metallic biomaterials and metallozis”, Journal of TOTBİD, 10(2): 83-86, (2011)
  2. Pasinli A. and Aksoy R. S., “Hydroxyapatite for artificial bone applications”, Biotechnology Magazine, 1: 41-51, (2010)
  3. Aydın İ., “An investigation of fracture and wear behavior of HA coatings deposited onto Ti6Al4V alloys in a new environment”, PhD Thesis, Celal Bayar University, Institute of Science, (2013)
  4. Aydın İ., Çetinel H., Pasinli A. and Yüksel M., “Fracturing and adhesion behavior of hydroxyapatite formed by a citric acid and sodium citrate buffer system”, Materials Testing, 58(2): 1 - 6, (2016)
  5. Pasinli A., “Hydroxyapatite for artificial bone applications”, Electronic Journal of Machine Technologies, 25 - 35, (2004)
  6. Kokubo T., Kim H. M., Miyaji F., Takadama H. and Miyazaki T., “Ceramic-metal and ceramic-polymer composites prepared by a biomimetic process”, Composites Part A, Applied Science and Manufacturing, 30: 405–409, (1999)
  7. Taş A. C., “Synthesis of biomimetic Ca-hydroxyapatite powders at 37 ºC in synthetic body fluids”, Biomaterials, 21: pp. 1429–1438, (2000
  8. Sepahvandi A., Moztarzadeh F., Mozafari M., Ghaffari M., and Raee N., “Photoluminescence in the characterization and early detection of biomimetic bone-like apatite formation on the surface of alkaline-treated titanium implant”, State of the art. Biointerfaces, 86: 390-396, (2011)
  9. Faure J., Balamurugan A., Benhayoune H., Torres P., Balossier G. and Ferreira J. M. F., “Morphological and chemical characterization of biomimetic bone like apatite formation on Ti6Al4V titanium alloy”, Materials Science and Engineering, 29: 1252-1257, (2009)
  10. Li F., Feng Q. L., Cui F. Z., Li H. D. and Schubert H., “A simple biomimetic method for calcium phosphate coating”, Surface & Coating Technology, 154: 88–93, (2002)
  11. Xiaobo C., Yuncang L., Peter D. H. and Cui’e W., “Microstructures and bond strengths of the calcium phosphate coatings formed on titanium from different simulated body fluids”, Materials Science and Engineering, 29: 165-171, (2009)
  12. Pasinli A., Yüksel M., Çelik E., Şener S. and Taş C. A., “A new approach in biomimetic synthesis of calcium phosphate coatings using lactic acid-Na lactate buffered body fluid solution”, Acta Biomaterialia, 6: 2282-2288, (2010)
  13. Çağlayan M. E., “Hydroxyapatite coating of Ti6A14V alloys in alanin - alanine sodium salt environment with biomimetic method and observing of some features”, M.Sc. Thesis, Celal Bayar