Journals / Selcuk Dental Journal / 2020 / Cilt: 7 - Sayı: 3

Biyomimetik poröz dental implantların konvansiyonel dental implantlarla statik, dinamik ve çarpma yükleme koşullarında davranışlarının karşılaştırılması (3 boyutlu sonlu eleman analizi)

Comparing static, dynamic and impact loading behavior of biomimetic porous dental implants with conventional dental implants (3d finite element analysis)

Pages
471–480
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Orta üçlüsü poröz biyomimetik implant tasarımı, çarpma yükleme stresini azaltmak için en başarılı tasarımdır.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Amaç: Kemiğe benzer elastik modül değerleri ve kemik dokusunun gelişimin izin vermesi sebebi ile biomimetik poröz yapılar, konvansiyonel implantların yerine önerilmiştir.
📊
Key Findings & Data:Ancak, farklı porözite oranına ve porözitenin farklı bölgelerde bulunmasını simüle edecek sınırlı çalışma vardır.
💡
Conclusion & Impact:Orta üçlüsü poröz biyomimetik implant tasarımı, çarpma yükleme stresini azaltmak için en başarılı tasarımdır.
🔬Design:Experimental Field Trial
📍Scope:2 adet
⚙️Variables:Domain Parameters

Abstract

Amaç: Kemiğe benzer elastik modül değerleri ve kemik dokusunun gelişimin izin vermesi sebebi ile biomimetik poröz yapılar, konvansiyonel implantların yerine önerilmiştir. Ancak, farklı porözite oranına ve porözitenin farklı bölgelerde bulunmasını simüle edecek sınırlı çalışma vardır. Bu çalışmanın amacı, konvansiyonel dental implantlar ile çeşitli bölgelerinde poröziteye sahip ve farklı miktarlarda porozite içeren dört farklı biyomimetik implant tasarımı etrafındaki kortikal ve spongioz kemik dokusunda meydana gelen stres dağılım düzeylerini değerlendirmektir. Gereç ve Yöntemler: 3 boyutlu sonlu eleman analizi için, üstçene posterior bölgede 2 adet implant üzerine yapılan 3 üyeli kanat uzantılı sabit bölümlü protez matematiksel olarak modellendi. Elde edilen model üzerine, dikey ve oblik uygulanmış; statik, dinamik ve çarpma yükleri uygulanmıştır. Vertikal yük olarak kronların merkezi fossaları üzerinde 300 N dikey yük uygulanmıştır. Oblik yüklemede her bir dişin fonksiyonel palatinal tüberkülüne 45 ° 'lik bir açı ile 50 N yük uygulanmıştır. Bulgular: Çarpma yüklerinde, distaldeki konvansiyonel implant üzerinde aşırı stres değerleri oluşmuştur (1030 MPa). Bu değer titanyum alaşımının (Ti-6Al-4V) nihai gerilme mukavemetinden (930 MPa) daha fazladır. Sonuçlar, tüm yüzeyi gözenekli ve orta üçlü bölümü gözenekli implantların tüm yükleme koşulları için distal implantta daha düşük stres değerleri gösterdiği şeklinde özetlenebilir. Sonuç: Stres dağılımı açısından; porözitenin yeri, porözite miktarından daha kritiktir. Çarpma yükleme, implant destekli protez için kritik bir parametredir. Biyomimetik poröz implantların tasarımı için çarpma yükünün gözlenmesi ve önlenmesi düşünülmelidir. Orta üçlüsü poröz biyomimetik implant tasarımı, çarpma yükleme stresini azaltmak için en başarılı tasarımdır.

Özet

Background: Porous structures instead of bulk structures have been suggested for implants because porous structures have elactic modulus similar to natural bone and allow bone tissue ingrowth. But there are limited studies to simulate porous implants with different amount of porosity at different locations The purpose of this study was to evaluate the stress distribution levels at cortical and spongious bone tissue that occurred around commercially available dental implants and four different biomimetic implant design with various porous parts and porosity amounts. Methods: 3-dimensional finite element analysis was conducted using mathematical models of unilateral 3-unit cantilever fixed partial dentures (FPD) subjected to vertical and oblique rotated static, dynamic and impact occlusal loads. Vertical load of 300 N was applied to the model over the central fossa of the crowns. Oblique load of 50 N were applied per tooth over the functional palatinal tubercule at an angle of 45 °. Results: Impact loading conditions create excessive stress values at distal dense titanium implants (1030 MPa). This was more than the ultimate tensile strength of dense titanium alloy Ti-6Al-4V (930 MPa). It might be summarized as fully porous and middle section porous implants showed lower stress values at distal implant for all loading conditions. Conclusion: The location of porosity is more critical than the amount of porosity for stress distribution. The distributions of stress at implants and surrounding bone mainly depended on the location of the porosity. Impact loading is a critical parameter for implant-supported prosthesis. Observance and prevention of impact loading should be considered for designing biomimetic porous implants. The porous biomimetic implant design with porous middle sections was the most successful design to decrease impact loading stress.

🔖

Cite This Article

ÇULHAOĞLU, A. K., TERZİOĞLU, H. (2020). Biyomimetik poröz dental implantların konvansiyonel dental implantlarla statik, dinamik ve çarpma yükleme koşullarında davranışlarının karşılaştırılması (3 boyutlu sonlu eleman analizi). Selcuk Dental Journal, Cilt: 7 - Sayı: 3, 471–480. https://ajindex.com/articles/301521

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. Xiong Y, Qian C, Sun J. Fabrication of porous titanium implants by three-dimensional printing and sintering at different temperatures. Dental Materials Journal. 2012;31:815-820
  2. Branemark PI. Osseointegration and its experimental background. The Journal of Prosthetic Dentistry. 1983;50:399-410
  3. Thelen S, Barthelat F, Brinson LC. Mechanics considerations for microporous titanium as an orthopedic implant material. Journal of Biomedical Materials Research Part A. 2004;69:601-610
  4. Leite D D, Nascimento F O, Graça, M L, Carvalho Y R, Cairo C A. Porous titanium for biomedical applications: an experimental study on rabbits. Medicina Oral, Patologia Oral y Cirugia Bucal. 2010; 15(2), e407-12
  5. Mour M, Das D, Winkler T, Hoenig E, Mielke G, Morlock MM, et al. Advances in porous biomaterials for dental and orthopaedic applications. Materials. 2010;3:2947-2974
  6. Wisutmethangoon S, Nu-Young P, Sikong L, Plookphol T. Synthesis and characterization of Porous titanium. Songklanakarin Journal of Science & Technology. 2008; 30(4)
  7. Spoerke ED, Murray NG, Li H, Brinson LC, Dunand DC, Stupp SI. A bioactive titanium foam scaffold for bone repair. Acta Biomater. 2005;1:523-533
  8. Liu X, Wu S, Yeung KW, Chan Y, Hu T, Xu Z, et al. Relationship between osseointegration and superelastic biomechanics in porous NiTi scaffolds. Biomaterials. 2011;32:330-338
  9. Karageorgiou V, Kaplan D. Porosity of 3D biomaterial scaffolds and osteogenesis. Biomaterials. 2005;26:5474-5491
  10. Schiefer H, Bram M, Buchkremer H, Stöver D. Mechanical examinations on dental implants with porous titanium coating. Journal of Materials Science: Materials in Medicine. 2009;20:1763-1770
  11. Chen L-j, Ting L, Li Y-m, Hao H, Hu Y-h. Porous titanium implants fabricated by metal injection molding. Transactions of Nonferrous Metals Society of China. 2009;19:1174-1179
  12. Shen H, Oppenheimer S, Dunand D, Brinson L. Numerical modeling of pore size and distribution in foamed titanium. Mechanics of Materials. 2006;38:933-944
  13. Gültekin B A, Gültekin P, Yalcın S. Application of finite element analysis in implant dentistry. Finite Element Analysis: New Trends and Developments. Rijeka, Croatia: InTech Publishing. 2012; 21-54
  14. El’Sheikh H, MacDonald B, Hashmi M. Finite element simulation of the hip joint during stumbling: a comparison between static and dynamic loading. Journal of Materials Processing Technology. 2003;143:249-255
  15. Kayabaşı O, Yüzbasıoğlu E, Erzincanlı F. Static, dynamic and