Journals / MN Oftalmoloji / 2009 / Cilt: 16 - Sayı: 3

Diagnostic tests used for the evaluation of nonarteritic anterior ıschemic optic neuropathy

Nonarteritik ön iskemik optik nöropatide kullanılan tanısal testlerin değerlendirilmesi

Pages
177–183
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: Clinically practical, reliable and cost-effective methods such as RAPD and brightness sense help in the diagnosis and evaluation of the severity of NAION.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Aim: To assess the sensitivity of the tests used for the evaluation of non-arteritic anterior ischemic optic neuropathy (NAION).
📊
Key Findings & Data:Material and Method: The clinical records of 23 patients with unilateral NAION were reviewed.
💡
Conclusion & Impact:Conclusion: Clinically practical, reliable and cost-effective methods such as RAPD and brightness sense help in the diagnosis and evaluation of the severity of NAION.
🔬Design:Review & Systematic Survey
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Aim: To assess the sensitivity of the tests used for the evaluation of non-arteritic anterior ischemic optic neuropathy (NAION). Material and Method: The clinical records of 23 patients with unilateral NAION were reviewed. Detailed neuro-ophthalmologic examination including relative afferent pupillary defect (RAPD), visual field analysis, brightness sense, color vision test was performed in all cases. Results: There was a significant correlation among RAPD, brightness sense and visual field measurements. While visual acuity compared with RAPD, brightness sense and visual field measurements, a mild correlation was noticed. The correlation between visual acuity and color vision was also significant. Conclusion: Clinically practical, reliable and cost-effective methods such as RAPD and brightness sense help in the diagnosis and evaluation of the severity of NAION.

Özet

Amaç: Nonarteritik ön iskemik optik nöropati (NÖİON)’nin tanısı ve şiddetinin değerlendirilmesinde kullanılan testlerin duyarlılıklarını, birbirleri arasındaki korelasyon ilişkilerini araştırmaktır. Gereç ve Yöntem: Tek gözünde ilk defa NÖİON geçiren 23 hasta çalışmaya dahil edildi. Oftalmolojik muayenelerle birlikte rölatif afferent pupil defekti (RAPD), parlaklık hissi, görme alanı ve renkli görme muayeneleri yapıldı. Bulgular: RAPD ve parlaklık hissi ölçümlerinde ve bunların görme alanı analizleri ile karşılaştırılmasında istatistiksel anlamlı lineer korelasyonlar bulundu. RAPD, parlaklık hissi ve görme alanı ölçümlerinin, görme keskinliği ölçümleri ile karşılaştırılmasında daha zayıf olmakla birlikte, anlamlı lineer korelasyonlar görüldü. Görme keskinliği ve renkli görme ölçümleri karşılaştırıldığında güçlü lineer korelasyon ilişkisi saptandı. Sonuç: Kolay uygulanabilir, ucuz ve güvenilir yöntemler olan, nötral dansite filtreleriyle yapılan kantitatif RAPD ve parlaklık hissi ölçümleri, NÖİON tanısında ve şiddetinin değerlendirilmesinde yardımcı olmaktadır.

🔖

Cite This Article

YAMEN, B., YAMAN, A., BAJİN, S. M. (2009). Diagnostic tests used for the evaluation of nonarteritic anterior ıschemic optic neuropathy. MN Oftalmoloji, Cilt: 16 - Sayı: 3, 177–183. https://ajindex.com/articles/296817

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (17)

  1. Hayreh SS, Joss KM, Podhajsky PA, Long CR. Systemic diseases associated with nonarteritic anterior ischemic optic neuropathy. Am J Ophthalmol. 1994
  2. McCulley TJ, Lam BL, Feuer WJ. A comparasion of risk factors for postoperative and spontaneous nonarteritic anterior ischemic optic neuropathy. J Neuroophthalmol 2005
  3. Kawasaki A, Moore P, Kordon RH. Variability of the relative afferent pupillary defect. Am J Ophthalmol 1995
  4. Rizzo JF, Lessell S. Optic neuritis and ischemic optic neuropathy. Arch Ophthalmol 1991
  5. Preston DS, Berstein L, Sadun AA. Office techniques for detecting optic neuropathies. J Neuro-ophthalmology 1988
  6. 8(5):245-50. 6.Gerling J, Meyer JH, Kommerell G. Visual field defect in optic neuritis and anterior ischemic optic neuropathy: distinctive features. Graefes Arch Clin Exp Ophthalmol 1988
  7. 236(3):88-92. 7.Hayreh SS, Podhajsky PA. Visual field defects in anterior ischemic optic neuropathy. Doc Ophthalmol Proc Ser 1979
  8. Martin TJ, Robison GD. Instrument for measuring relative brightness perseption. Am J Ophthalmol 1994
  9. Sadun AA, Schaechter JD. Retinal ganglion axon diametres and their differential distribution to the visual nuclei in man. Invest Ophthalmol Vis Sci 1983
  10. 24 (3 suppl):236. 10.Kelman SE. Ischemic optic neuropathy. In Miller NR
  11. Newman NJ, editors. Walsh and Hoyt's 5th edition Vol 1. Baltimore: Wiliams&Wilkins, 1998
  12. Thompson HS, Gorbett JJ, Cox TA. How to measure the relative afferent pupillary defect. Surv Ophthalmol 1981
  13. Rosenberg ML, Oliva AO. The use of crossed polarized filters in the measurement of the relative afferent pupillary defect. Am J Ophthalmol 1990
  14. Carolyn GH, Alexander JB. The detection of a relative afferent pupillary defect. Am J Ophthalmol 2002
  15. Kardon RH, Haupert CL, Thompson HS. The relationship between static perimetry and the relative afferent pupillary defect. Am J Ophthalmol 1993,115:351-6. 15.Johnson LN, Hill RA, Bartholomew MJ. Correlation of afferent pupillary defect with visual field loss on automated perimetry. Ophthalmology 1988
  16. Thompson HS, Montague P, Cox TA, Corbett JJ. The relationship between visual acuity, pupillary defect and visual field loss. Am J Ophthalmol 1982
  17. 93(6):681-8. 17.Kerrison JB, Buchanon K, Rosenberg ML, Clark R, Andreason K, Alfaro DV, Grossnicklaus HE, Kerrigan-Baumrind LA, Kerrigan DF, Miller NR, Quigley HA. Quantification of optic ne