Evaluation of optic nerve diameter with ultrasonography

Optik sinir kalınlığının ultrasonografik olarak değerlendirilmesi

Pages
185–187
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Also the measurements made in primary position and 30° abduction of the eye and the measurements made by 60° and 40° prob scanning angles were not significantly different.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Optic nerve diameter was measured ultrasonographically in 54 eyes of 27 normal humans and different ultrasonographic tecniques for the measurement of the optic nerve diameter were compared.
📊
Key Findings & Data:For the measurements of the optic nerve diameter, A and B mode ultrasonography were performed at primary position of the eyes and at 30° of abduction using 40° and 60° prob scanning angles of the ultrasonography instrument.
💡
Conclusion & Impact:Also the measurements made in primary position and 30° abduction of the eye and the measurements made by 60° and 40° prob scanning angles were not significantly different.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Optic nerve diameter was measured ultrasonographically in 54 eyes of 27 normal humans and different ultrasonographic tecniques for the measurement of the optic nerve diameter were compared. For the measurements of the optic nerve diameter, A and B mode ultrasonography were performed at primary position of the eyes and at 30° of abduction using 40° and 60° prob scanning angles of the ultrasonography instrument. The mean optic nerve diameter was 3.09±0.68mm and there was no significant difference between the measurements made with A and B mode ultrasonography. Also the measurements made in primary position and 30° abduction of the eye and the measurements made by 60° and 40° prob scanning angles were not significantly different.

Özet

Optik sinir kalınlığının ultrasonografik otarak belirlenmesi ve optik sinir kalınlık ölçümünde kullanılan ultrasonografi tekniklerinin karşılaştırılması amacı ile 27 .normal bireyin 54 gözünde optik sinir kalınlıkları ultrasonografik olarak ölçüldü. Ölçümler A ve 8 mod ultrasonografi kullanılarak, göz primer pozisyonda ve 30° abdüksiyonda iken yapıldı. Ayrıca tüm ölçümler ultrasonografi cihazının 60° ve 40° B mod prob tarama açıları kullanılarak tekrarlandı. Sonuç olarak ortalama optik sinir kalınlığı 3.09±0.68mm olarak bulundu. Elde edilen optik sinir kalınlık değerleri açısından karşılaştırıldıklarında A ve B mod ultrasonografi, gözün primer pozisyon ve 30° abdüksiyonunda yapılan ölçümler, 60° ve 40° B mod prob tarama açıları ile elde edilen ölçümler arasında anlamlı farka rastlanmadı.

🔖

Cite This Article

AKMAN, A., AYDIN, P. (1997). Evaluation of optic nerve diameter with ultrasonography. MN Oftalmoloji, Cilt: 4 - Sayı: 3, 185–187. https://ajindex.com/articles/296595