Journals / MN Oftalmoloji / 2013 / Cilt: 20 - Sayı: 4

The evaluation of corneal biomechanical properties of diabetic patients

Diyabet olgularında korneanın biyomekanik parametrelerinin değerlendirilmesi

Pages
222–226
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

But IOPg and IOPcc values are not affected by diabetes.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Aim: To evaluate corneal biomechanical properties of diabetic patients with ocular re- sponse analyzer (ORA).
📊
Key Findings & Data:Material and Method: Eighty eyes of 40 patients records were retrospectively examined.
💡
Conclusion & Impact:But IOPg and IOPcc values are not affected by diabetes.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Aim: To evaluate corneal biomechanical properties of diabetic patients with ocular re- sponse analyzer (ORA). Material and Method: Eighty eyes of 40 patients records were retrospectively examined. Twenty of them were non-diabetic and constituted group 1 and 20 of them were diabetic and constituted group 2. Corneal hysteresis (CH), corneal resistance factor (CRF), corneal com- pensated intraocular pressure (IOPcc) and goldmann-correlated intraocular pressure (IOPg) measures taken by ORA and central corneal thickness (CCT) evaluated with ultrasonic pachymeter were recorded. Results: Mean CH and CRF levels in group 1 were 10.9±1.8. 11.2±1.4 mmHg, respectively and these levels in group 2 were 9.2±0.8 ve 9.5±1.4 mmHg, respectively. Mean CH and CRF were significantly higher in diabetic patients (p<0.05). Mean IOPg and IOPcc in group 1 were 15.5±4.8 mmHg and 15.4±4.6 mmHg. Mean IOPg and IOPcc in group 2 were 16.2±3.8 mmHg and 17.1±4.1mmHg. Mean IOPg and IOPcc levels were not significantly different be- tween groups (p>0.05). Conclusion: Diabetes affects corneal biomechanical properties, with increased CCT, CH and CRF. But IOPg and IOPcc values are not affected by diabetes.

Özet

Amaç: Diyabet olgularında Oküler Cevap Analizörü (OCA) ile ölçülen korneanın biyome- kanik özelliklerini değerlendirmek. Gereç ve Yöntem: Retinopati bulguları gelişmemiş diyabeti olan 20 olgu ile herhangi bir göz ya da sistemik hastalığı olmayan 20 olgunun toplam 80 gözüne ait kayıtlar retrospektif olarak incelendi. Yirmi diyabetik olgu Grup 1, 20 sağlıklı olgu ise Grup 2 olarak sınıflandırıl- dı. OCA ile korneal histerezis (KH), korneal rezistan faktör (KRF), Goldmann korele göz içi basıncı (GİBg), kornea kompanse göz içi basıncı (GİBkk) ölçümleri yapıldı. Ultrasonik paki- metri yöntemiyle santral korneal kalınlık (SKK) ölçümü yapıldı. Bulgular: Ortalama KH ve KRF değerleri, Grup 1’de sırasıyla 10,9±1,8 mmHg ve 11,2±1,4 mmHg; Grup 2’de ise sırasıyla 9,2±0,8 mmHg ve 9,5±1,4 mmHg olarak bulundu. Ortalama KH ve KRF değerleri diyabetik olgularda istatistiksel olarak anlamlı derecede yük- sekti (p 0,05). Sonuç: Diyabetik hastalarda ortalama SKK, KH ve KRF değerlerinin normal gruba oran- la daha yüksek olduğu saptandı. Diyabetin korneanın biyomekanik yapısı üzerine etkisi oldu- ğu belirlenirken,GİBg ve GİBkk değerlerini etkilemediği saptandı.

🔖

Cite This Article

KOÇAK, A. A., BEYAZYILDIZ, Ö., KÖKLÜ, G., ÖZÇALIŞKAN, Ş., ÇOBAN, P. (2013). The evaluation of corneal biomechanical properties of diabetic patients. MN Oftalmoloji, Cilt: 20 - Sayı: 4, 222–226. https://ajindex.com/articles/295704

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Kirwan C. O'Keefe M. Lanigan B. Corneal hysteresis and in- traocular pressure measurement in children using the reichert Ocular Response Analyzer. Am J Ophthalmol 2006;142:990-2
  2. Sullivan-Mee M. Katiyar S. Pensyl D. et al. Relative impor- tance of factors affecting corneal hysteresis measurement. Optom Vis Sci 2012;89:803-11
  3. Kotecha A. Elsheikh A. Roberts CR. et al. Corneal thickness- and age related biomechanical properties of the cornea measured with the Ocular Response Analyzer. Invest Ophthalmol Vis Sci 2006;47:5337-42
  4. Moreno-Montañés J. Maldonado MJ. García N. Mendiluce L. et al. Reproducibility and clinical relevance of the ocular re- sponse analyzer in nonoperated eyes: corneal biomechanical and tonometric implications. Invest Ophthalmol Vis Sci 2008; 49:968-74
  5. Abitbol O. Bouden J. Doan S et al. Corneal hysteresis meas- ured with the Ocular Response Analyzer in normal and glau- comatous eyes. Acta Ophthalmol 2010;88:116-9
  6. Kotecha A.What biomechanical properties of the cornea are relevant for the clinician? Surv Ophthalmol 2007;52:109-114 7. Goldich Y. Barkana Y. Gerber Y. et al. Effect of diyabetes mel- litus on biomechanical parameters of the cornea. J Cataract Refract Surg 2009;35:715-9
  7. Sahin A. Bayer A. Corneal hysteresis changes in diyabetic eyes. J Cataract Refract Surg 2010;36:361
  8. Kuo IC. Broman A. Pirouzmanesh A. et al. Is there an associ- ation between diabetes and keratoconus? Ophthalmology 2006;113:184-90
  9. Scheler A. Spoerl E. Boehm AG. Effect of diyabetes mellitus on corneal biomechanics and measurement of intraocular pressure. Acta Ophthalmol 2012;90:447-51
  10. Lee JS. Oum BS. Choi HY. et al. Differences in corneal thick- ness and corneal endothelium related to duration in diya- betes. Eye (Lond) 2006;20:315-8
  11. Su DH. Wong TY. Wong WL. et al. Diyabetes, hyperglycemia, and central corneal thickness: the Singapore Malay Eye Study. Ophthalmology 2008;115:964-8
  12. Renier C. Zeyen T. Fieuws S. et al. Comparison of ocular re- sponse analyzer, dynamic contour tonometer and Goldmann applanation tonometer. Int Ophthalmol 2010;30:651-9
  13. Burgoyne CF. Downs JC. Bellezza AJ. et al. The optic nerve head as a biomechanical structure a new paradigm: for un- derstanding the role of IOP related stress and strain in the pathophysiology of glaucomatous optic nerve head damage. Prog Retin Eye Res 2005;24:39-73.