Cauda equina sensory conduction time in normal adult humans

Pages
136–140
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Themean CE-SCT value is similar to those found for CE-MTC.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: The clinical usefulness of the cauda equina motor conduction time (CE-MCT) is well established either by magnetic or electrical stimulation of the lumbar roots at the lumbar spine levels.
📊
Key Findings & Data:Methods: Lumbar laminar electrical stimulation from the level of theL1 and L5 vertebrae was applied using needle electrodes.
💡
Conclusion & Impact:Themean CE-SCT value is similar to those found for CE-MTC.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Objective: The clinical usefulness of the cauda equina motor conduction time (CE-MCT) is well established either by magnetic or electrical stimulation of the lumbar roots at the lumbar spine levels. However, the cauda equina sensory conduction time (CE- SCT) is not studied systematically in human adults. Methods: Lumbar laminar electrical stimulation from the level of theL1 and L5 vertebrae was applied using needle electrodes. The smallest M-responses obtained from both soleus muscles were considered as the motor threshold for the L1and L5 motor root levels. Afterwards, with the needles in the same place, the connection cables were removed from the stimulation channel and replaced to the recording channel, then the sensory program of the electromyograph was selected. The posterior tibial nevre was excited with superficia lbipolar electrodes from the popliteal fossa, and after a very slight muscle twitch was observed the intensity was reduced slightly. Therefore, the pure sensory fibers were stimulated. Cauda equina sensory action potentials were recorded and averaged at the laminar levels of L1 and L5 in the spine. Twenty adult normal controls were studied. Results: The monopolar recordings of cauda equina sensory responses at the L1 and L5 laminar levels were measured from their first positive peaks and the CE-SCT was found as 1.9±0.4 msec (mean ± SD) and ranged from 1.0 to 2.8 msec. Conclusion: The method of CE-SCT recording and calculation is very easy to use and applicable in all normal adult subjects. Themean CE-SCT value is similar to those found for CE-MTC.

🔖

Cite This Article

EKİNCİ, A. S., TABAKOGLU, A. Y., OTO, A., BADEMKIRAN, F., ERTEKİN, C. (2019). Cauda equina sensory conduction time in normal adult humans. Neurological sciences and neurophysiology (Online), Cilt: 36 - Sayı: 3, 136–140. https://ajindex.com/articles/290536

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Chartrain AG, Awad AJ, Mascitelli JR, et al. Novel and emerging technologies for endovascular thrombectomy. Neurosurg Focus 2017
  2. E12. [CrossRef] 2. Akpınar S, Yılmaz G. Early middle cerebral artery stenosis following stent-assisted thrombectomy. Interv Neuroradiol 2015
  3. [CrossRef] 3. Enomoto Y, Takagi T, Matsubara H, et al. Delayed stenosis in the ıntracranial vessels following endovascular treatment for acute stroke. J Vasc Interv Radiol 2015
  4. [CrossRef] 4. Kurre W, Pérez MA, Horvath D, Schmid E, Bäzner H, Henkes H. Does mechanical thrombectomy in acute embolic stroke have long-term side effects on intracranial vessels? An angiographic follow-up study. Cardiovasc Intervent Radiol 2013
  5. [CrossRef] 5. Power S, Matouk C, Casaubon LK, et al. Vessel wall magnetic resonance imaging in acute ischemic stroke: effects of embolism and mechanical thrombectomy on the arterial wall. Stroke 2014
  6. [CrossRef] 6. Nogueira RG, Levy EI, Gounis M, Siddiqui AH. The Trevo device: preclinical data of a novel stroke thrombectomy device in two different animal models of arterial thrombo-occlusive disease. J Neurointerv Surg 2011
  7. [CrossRef] 7. Akins PT, Amar AP, Pakbaz RS, Fields JD
  8. SWIFT Investigators. Complications of endovascular treatment for acute stroke in the SWIFT trial with solitaire and Merci devices. AJNR Am J Neuroradiol 2014
  9. [CrossRef] 8. Gascou G, Lobotesis K, Machi P, et al. Stent retrievers in acute ischemic stroke: complications and failures during the perioperative period. AJNR Am J Neuroradiol 2014
  10. [CrossRef] 9. Macke JJ, Bellew MP, Hellinger FR Jr. Delayed stenosis following stentriever use in acute stroke intervention. J Neurointerv Surg 2015
  11. e17. [CrossRef] 10. Chung GH, Kwak HS, Hwang SB, Jin GY. High resolution MR imaging in patients with symptomatic middle cerebral artery stenosis. Eur J Radiol 2012
  12. [CrossRef] 11. Marquering HA, Nederkoorn PJ, Smagge L, Gratama van Andel HA, van den Berg R, Majoie CB. Performance of semiautomatic assessment of carotid artery stenosis on CT angiography: clarification of differences with manual assessment. AJNR Am J Neuroradiol 2012
  13. [CrossRef] 12. Machi P, Costalat V, Lobotesis K, et al. Solitaire FR thrombectomy system: immediate results in 56 consecutive acute ischemic stroke patients. J Neurointerv Surg 2012
  14. [CrossRef] 13. Heitzer T, Rudolph V, Schwedhelm E, et al. Clopidog