Journals / Organic Communications / 2019 / Cilt: 12 - Sayı: 3

A Calix[4]arene-tren modified electrode for determination of Lead ions in aqueous solution

Pages
160–168
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The results indicate that Calix-tren modified GC electrode provides good electron transmission pathway than bare GC electrode.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, a simple and sensitive electrochemical sensor based on Calix[4]arene-tren (Calix-tren) modified glassy carbon (GC) electrode was developed for the determination of Pb (II)ions.
📊
Key Findings & Data:The optimum pH value was selected as 7.0.
💡
Conclusion & Impact:The results indicate that Calix-tren modified GC electrode provides good electron transmission pathway than bare GC electrode.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

In this study, a simple and sensitive electrochemical sensor based on Calix[4]arene-tren (Calix-tren) modified glassy carbon (GC) electrode was developed for the determination of Pb (II)ions. Electrochemical behavior of Calix-tren modified electrodes were investigated by using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The results indicate that Calix-tren modified GC electrode provides good electron transmission pathway than bare GC electrode. The amount of Pb(II) was determined by differential pulse anodic stripping voltammetric analysis as a sensitive detection technique. The experimental parameters such as pH, deposition time and deposition potentialwere optimized. The optimum pH value was selected as 7.0. The effect of deposition potential and deposition time on the peak current was tested and the optimum values were chosen as -1.2 V and 120 s, respectively. Under the optimal conditions, the working range of the developed sensor was determined as 0.48-2.31 μM, limit of detection (LOD) was 0.11 μM and the RSD obtained in the reproducibility study was 2.78 %. It was also found that the developed method could be used in the determination of Pb (II)ions in real samples with satisfactory results

🔖

Cite This Article

KOCER, M. B., ERDOGAN, Z. O., OGUZ, M., KÜÇÜKKOLBAŞI, S., YILMAZ, M. (2019). A Calix[4]arene-tren modified electrode for determination of Lead ions in aqueous solution. Organic Communications, Cilt: 12 - Sayı: 3, 160–168. https://ajindex.com/articles/288468

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Nur Abdul Aziz, S.F.; Zawawi, R.; Alang Ahmad, S.A. An Electrochemical sensing platform for the detection of lead ions based on dicarboxyl‐Calix [4] arene. Electroanalysis2018,30(3), 533-542. [2]Schock, M.R. Causes of temporal variability of lead in domestic plumbing systems. Environment. Monitor. Assesment1990,15(1),59-82. [3]Fu, F.; Wang, Q. Removal of heavy metal ions from wastewaters: a review. J.Environment. Man.2011,92(3),407-418. [4]Yilmaz, M.; Sayin, S. Calixarenes in organo and biomimetic catalysis, in Calixarenes and Beyond. Springer2016,719-742. [5]Bhatti, A.A.; Oguz, M.; Yilmaz, M. One-pot synthesis of Fe3O4@ Chitosan-pSDCalix hybrid nanomaterial for the detection and removal of Hg2+ion from aqueousmedia. Appl.Surface Sci.2018,434, 1217-1223. [6]Sulak, M.; Kursunlu, A. N.; Girgin, B.; Ozen Karakus, O.; Guler, E. A highly selective fluorescent sensor for mercury (II) ion based on Bodipy and Calix [4] arene bearing triazolenaphthylene groups; synthesis and photophysical investigations. J.Photochem.Photobiol.A: Chemistry2017,349, 129-137. [7]Yilmaz, M.; Karanastasis, A., A.; Chatziathanasiadou, M., V.; Oguz, M.; Kougioumtzi, A.; Clemente, N.; Kellici, T. K.; Zafeiropoulos, N., E.; Avgeropoulos, A.; Mavromoustakos, T.; Dianzani, U.; Karakurt, S.; Tzakos, A. G. Inclusion of quercetin in gold nanoparticles decorated with supramolecular hosts amplifies its tumor targeting properties. ACS Appl.Bio Materials2019, 27, 2715-2725. [8]Oguz, M.; Bhatti, A. A.; Karakurt, S.; Aktas, M.; Yilmaz, M. New water soluble Hg2+selective fluorescent calix [4] arenes: Synthesis and application in living cells imaging. Spectrochim.Acta Part A: Mol.Biomol. Spectr.2017,171, 340-345. [9]Gutsche, C.D.; Muthukrishnan, R. Calixarenes. 1. Analysis of the product mixtures produced by the base-catalyzed condensation of formaldehyde with para-substituted phenols. J.Org.Chem.1978,43(25), 4905-4906. [10]Kucukkolbasi, S.;Temur, O.; Kara, H.; Khaskheli, A. R. Monitoring of Zn(II), Cd(II), Pb(II) and Cu(II) during refining of some vegetable oils using differential pulse anodic stripping voltammetry. Food Anal. Meth.2014,7(4), 872-878. [11]Kucukkolbasi, S.;Erdogan, Z. O.;Barek, J.;Sahin, M.;Kocak, N. A novel chitosan nanoparticle-schiff base modified carbon paste electrode as a sensor for the determination of Pb (II) in waste water. Int.J.Electrochem. Sci.2013, 8, 2164-2181. [12]Liu, X.; Li, Y.; Liang. J.; Zhu, W.; Xu, J.; Su, R.; Yuan, L.; Sun, C. Aptamer contained triple-helix mole