⚡ TL;DR(Too Long; Didn't Read)

It may show lesions that might otherwise escape detection.Key Words: Magnetic resonance imaging, Pituitary microadenoma, Dynamic MRI

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: In this study our purpose was to compare efficiency in detecting microadenoma between conventional unenhanced MRI and contrast-enhanced MRI with dynamic fast spin- echo method.Methods: Thirty-two patients with suspected pituitary microadenoma had unenhanced, dynamic fast spin-echo contrast enhanced and conventional contrast-enhanced MR imaging of the pituitary gland.
📊
Key Findings & Data:All MR studies were reviewed for the presence or absence of any pituitary focal pathological intensity consistent with microadenoma.Result: A pituitary lesion consistent inappearance with a microadenoma was detected on dynamic fast spin-echo images in 17 of the 32 patients, on unenhanced images in 8 patients, and on conventional contrast-enhanced images in 11 patients.Conclusion: Dynamic fast spin-echo imaging is a useful supplemental sequence in patients undergoing MR imaging because of pituitary endochrinopathy.
💡
Conclusion & Impact:It may show lesions that might otherwise escape detection.Key Words: Magnetic resonance imaging, Pituitary microadenoma, Dynamic MRI
🔬Design:Review & Systematic Survey
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Objective: In this study our purpose was to compare efficiency in detecting microadenoma between conventional unenhanced MRI and contrast-enhanced MRI with dynamic fast spin- echo method.Methods: Thirty-two patients with suspected pituitary microadenoma had unenhanced, dynamic fast spin-echo contrast enhanced and conventional contrast-enhanced MR imaging of the pituitary gland. All MR studies were reviewed for the presence or absence of any pituitary focal pathological intensity consistent with microadenoma.Result: A pituitary lesion consistent inappearance with a microadenoma was detected on dynamic fast spin-echo images in 17 of the 32 patients, on unenhanced images in 8 patients, and on conventional contrast-enhanced images in 11 patients.Conclusion: Dynamic fast spin-echo imaging is a useful supplemental sequence in patients undergoing MR imaging because of pituitary endochrinopathy. It may show lesions that might otherwise escape detection.Key Words: Magnetic resonance imaging, Pituitary microadenoma, Dynamic MRI

🔖

Cite This Article

EKİNCİ, G., BALTACIOĞLU, F., ELMACI, İ., PAMİR, M. N., ERZEN, C. (2001). DYNAMIC MR IMAGING IN THE DETECTION OF PITUITARY MICROADENOMA. Marmara Medical Journal, Cilt: 14 - Sayı: 1, 23–26. https://ajindex.com/articles/284250

References (6)

  1. Sakamoto Y, Mutsumasa T, Korogi Y, Bussaka if, Ushio Y. normal and abnormal pituitary glands: gadopentetate dimegiumin-enhanced MR imaging. Radiology 1991;I 78:441-445.
  2. Miki Y, Matsuo M, Sadahiko H, et al. Pituitary adenomas and normal pituitary tissue: enhancement patterns on gadopentetate- enhanced MR imaging. Radiology 1990;177:35-38.
  3. Finelli DA, Kaufmann B. Varied microcirculation of pituitary adenomas at rapid, dynamic, contrast-enhanced MR imaging. Radiology 1993; 189:205-210.
  4. Stadnik T, Stevennaert A, Beckers A, Luypaert R, Buisseret T, Osteaux M. Pituitary microadenomas: diagnosis with two- and three-dimentional MR imaging at 1.5T before and after injection of gadoiium. Radiology 1990;176:419-428.
  5. Davis PC, Hoffman JC Jr, Spencer T, Tindall GT, Braun IF. MR imaging of pituitary adenoma: CT, clinical, and surgical correlation. AJR 1987; 148:797-802.
  6. Hewton DR, Dillon WP, Horman D, Hewton TH, Wilson CB. Gd-DTPA-enhanced MR imaging of pituitary adenomas. AJHR 1989; 10:949-954.