Wide band acoustic immitancemetry

Geniş bant akustik immitansmetre

Pages
126–131
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

It is the purpose of this study to explain the superiority of WBT and its differences from traditional tympanometry.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Acoustic Immitancemetry comprise recording the reflected pure tone sound from the eardrum sent which was delivered from the probe at the outer ear canal.
📊
Key Findings & Data:Traditional 226 Hz and 1000 Hz probe tone tympanometries are usually used in clinics but it’s not enough to identify middle ear disorders.
💡
Conclusion & Impact:It is the purpose of this study to explain the superiority of WBT and its differences from traditional tympanometry.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Acoustic Immitancemetry comprise recording the reflected pure tone sound from the eardrum sent which was delivered from the probe at the outer ear canal. It provides objective information about the condition of the middle ear. Traditional 226 Hz and 1000 Hz probe tone tympanometries are usually used in clinics but it’s not enough to identify middle ear disorders. Wideband Tympanometry (WBT) uses click stimuli covering a broad frequency range (226 Hz-8000 Hz). WBT measures sounds that are reflected back from the middle ear and absorbed by the middle ear. The sound that is reflected back from the middle ear is called reflectance, the sound that is absorbed by the middle ear is called absorbance. It is the purpose of this study to explain the superiority of WBT and its differences from traditional tympanometry.

Özet

Akustik immitansmetri ölçümü dış kulak kanalından verilen saf sesin kulak zarından yansıdıktan sonra kaydedilmesiyle oluşur. Bu kayıt sonucunda orta kulağın durumu hakkında objektif bilgiler elde edilir. Standart olarak kliniklerde geleneksel immitansmetri olarak isimlendirilen 226 Hz ve 1000 Hz prob ton uyaran verilen immitansmetri kullanılmaktadır. Fakat bu yöntem orta kulağın durumu ile ilgili bilgi sağlamada yeterli olmamaktadır. Geniş Bant Timpanometri ölçümü ile (GBT), dış kulak kanalından geniş bir frekans aralığını (226-8000 Hz) kapsayan klik uyaran verilerek ölçüm yapılmaktadır. Bu sırada orta kulakta absorbe edilen ve orta kulaktan yansıyan ses miktarı ölçülmektedir. Orta kulaktan yansıyan ses Reflektans, orta kulak tarafından soğurulan ses Absorbans olarak tanımlanır. Bu makalenin amacı, geniş bant timpanometrinin geleneksel timpanometriye göre üstün yönleri ve farklılıkları açıklamaktır.

🔖

Cite This Article

GÜMÜŞ, B., TOPÇU, M. T. (2018). Wide band acoustic immitancemetry. Medeniyet Medical Journal, Cilt: 33 - Sayı: 2, 126–131. https://ajindex.com/articles/283291

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Musiek FE, & Baran JA. The auditory system: anatomy, physiology and clinical correlates. Allyn & Bacon. 2007
  2. Hall JW. Introduction to Audiology Today. Pearson Higher Ed. 2013
  3. Katz J. Basic Principles of Acoustic Immitance Measures. Handbook of Clinical Audiology, 2002;11:159-73
  4. Feeney MP, Hunter LL, Kei J, Lilly DJ, Margolis RH, Nakajima HH,. & Schairer KS. Consensus statement: Eriksholm workshop on wideband absorbance measures of the middle ear. Ear and Hearing. 2013;34:78-9.
  5. Rosowski JJ, Stenfelt S, & Lilly D. An overview of wideband immittance measurements techniques and terminology: You say absorbance, I say reflectance. Ear and Hearing. 2013;34(0 1):9.
  6. Hudde H. Measurement of the eardrum impedance of human ears. Journal of the Acoustical Society of America. 1983;73:242-7.
  7. Keefe D, Ling R, & Bulen J. Method to measure acoustic impedance and reflection coefficient. Journal of the Acoustical Society of America, 1992;91:470-85.
  8. Lynch TJ, III, Peake WT, & Rosowski JJ. Measurements of the acoustic input impedance of cat ears: 10 Hz to 20 kHz. Journal of the Acoustical Society of America. 1994;96:2184-2209.
  9. Stinson MR, Shaw EAG, & Lawton BW. Estimation of acoustical energy reflectance at the eardrum from measurements of pressure distribution in the human ear canal. Journal of the Acoustical Society of America. 1982;72:766-773.
  10. Voss SE, & Allen JB. Measurement of acoustic impedance and reflectance in the human ear canal. Journal of the Acoustical Society of America. 1994;95:372-84.
  11. Keefe DH, Bulen JC, Arehart KH, & Burns EM. Ear-canal impedance and reflection coefficient in human infants and adults. Journal of the Acoustical Society of America. 1993;94:2617-38.
  12. Shaw EAG, & Stinson MR. Network concepts and energy flow in the human middle ear. Journal of the Acoustical Society of America. 1981;69(Suppl.1):43.
  13. Shahnaz N, & Bork K. Wideband reflectance norms for Caucasian and Chinese young adults. Ear and Hearing. 2006;27(6):774-88.
  14. Beers A, Shahnaz N, Westerberg B, Kozak FK. Wideband reflectance (WBR) in normal Caucasian and Chinese schoolaged c