Journals / Mathematical and Computational Applications / 2003 / Cilt: 8 - Sayı: 1

Evaluation of control methods on a structural system

Pages
369–376
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

At the end of the study, the time history of the storey displacements, control voltage and frequency response of the both uncontrolled, PID, LQR and sliding mode controlled structures have been presented and results have been compared.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, PID, LQR and sliding mode controllers are designed as active seismic isolation devices on a multi degrees of freedom structure.
📊
Key Findings & Data:Since the model might have uncertainties and/or parameter changes, sliding mode control has been introduced because of its well-known robust character and superior performance.
💡
Conclusion & Impact:At the end of the study, the time history of the storey displacements, control voltage and frequency response of the both uncontrolled, PID, LQR and sliding mode controlled structures have been presented and results have been compared.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

In this study, PID, LQR and sliding mode controllers are designed as active seismic isolation devices on a multi degrees of freedom structure. At first PID control is applied as a conventional method. Since this control method can be applied easily and well known widely, it has an important role in control applications. Secondly, a LQR is designed to suppress the vibrations of the structural system. But these methods are not insensitive to parameter changes. Since the model might have uncertainties and/or parameter changes, sliding mode control has been introduced because of its well-known robust character and superior performance. Additionally, this control method can easily be applied to non-linear systems. The simulated system has four stories. A disturbance input representing earthquake is applied to the base. At the end of the study, the time history of the storey displacements, control voltage and frequency response of the both uncontrolled, PID, LQR and sliding mode controlled structures have been presented and results have been compared.

🔖

Cite This Article

YAĞIZ, N., ERTAL, C. (2003). Evaluation of control methods on a structural system. Mathematical and Computational Applications, Cilt: 8 - Sayı: 1, 369–376. https://ajindex.com/articles/280461

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (7)

  1. B.C.Lin, I.G. Tadjbakhsh, A.S. Papageorgiou, G. Ahmadi, Performance of Earthquake Isolation Systems, Journal of Engineering Mechanics, 116-2, 446-461, 1990
  2. S.C. Sinha,G. Li, Optimal design of Base-Isolated Structures with Dynamic Absorbers, Journal of Engineering Mechanics, 120-2, 221-231, 1994
  3. T.Watanabe, K. Yoshida, Y. Fukunishi, Simultaneous Control of Vertical and Horizontal Vibrations of Base-Isolated Buildings Using Bidirectional Active Dynamic Vibration Absorber, Proceedings of the 1999 AS ME Design Engineering Technical Conferences, Las Vegas, 1999
  4. M.P. Singh, E. E. Matheu, L. E. Suarez, Active ad Semi-Active Control of Structures Under Seismic Excitation, Earthquake Engineering and Stuctural Dynamics, 26, 193-213,1997
  5. Sabanovic, Chattering Free Sliding Mode, in Proceedings of the 1 Turkey Automatic Control Symposium, Istanbul, 1994
  6. J.N. Yang, J.C. Wu, A.K. Agrawal, Sliding Mode Control for Nonlinear and Hysteretic Structures, Journal of Engineering Mechanics 121-12, 1330-1339, 1995
  7. K. Ogata, Modern Control Engineering, Prentice-Hall, New Jersey, 1990.