Reliable information on hemodynamic alterations in arteries can be obtained by evaluation of these sonograms.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, Doppler signals recorded from arteries of 105 subjects were processed by PC-computer using fast Fourier transform, and least squares modified Yule-Walker autoregressive moving average methods.
📊
Key Findings & Data:By using these spectrum analysis techniques, the variations in the shape of the Doppler spectrums as a function of time were presented in the form of sonograms in order to obtain medical information.
💡
Conclusion & Impact:Reliable information on hemodynamic alterations in arteries can be obtained by evaluation of these sonograms.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

In this study, Doppler signals recorded from arteries of 105 subjects were processed by PC-computer using fast Fourier transform, and least squares modified Yule-Walker autoregressive moving average methods. By using these spectrum analysis techniques, the variations in the shape of the Doppler spectrums as a function of time were presented in the form of sonograms in order to obtain medical information. These sonograms were then used to compare the applied methods in terms of their frequency resolution and the effects in determination of stenosis and occlusion in arteries. Reliable information on hemodynamic alterations in arteries can be obtained by evaluation of these sonograms.

🔖

Cite This Article

ÜBEYLİ, E. D., IŞIK, H., GÜLER, İ. (2003). Application of FFT and ARMA spectral analysis to arterial doppler signals. Mathematical and Computational Applications, Cilt: 8 - Sayı: 1, 311–318. https://ajindex.com/articles/280154

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (7)

  1. D.H. Evans, W.N. McDicken, R. Skidmore, J.P. Woodcock, Doppler Ultrasound: Physics, Instrumentation and Clinical Applications, Wiley, Chicester, 1989
  2. N.F. Güler, M.K. Kıymık, İ. Güler, Comparison of FFT and AR-based sonogram outputs of 20 MHz pulsed Doppler data in real time, Comput. Biol. Med., 25, 383-391, 1995
  3. N.F. Güler, M.K. Kıymık, İ. Giiler, Autoregressive-based sonogram output of 20 MHz pulsed Doppler data, Medical Progress through Technology, 21, 105-110, 1995
  4. İ. Güler, F. Hardalaç, S. Müldür, Determination of aorta failure with the application of FFT, AR and wavelet methods to Doppler technique, Comput. Biol. Med., 31, 229-238, 2001
  5. J.G. Proakis, D.G. Manolakis, Digital Signal Processing Principles, Algorithms, and Applications, Prentice Hall, New Jersey, 1996
  6. S.M. Kay, S.L. Marple, Spectrum analysis - A modern perspective, Proceedings of the IEEE, 69, 1380-1419, 1981
  7. H. Akaike, A new look at the statistical model identification, IEEE Transactions on Automatic Control, AC-19, 716-723, 1974.