Journals / Haseki Tıp Bülteni / 2010 / Cilt: 48 - Sayı: 4

Electrical injuries: The demographical and clinical features

Elektrik yaralanmaları: Demografik ve klinik özellikler

Pages
139–141
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The overall mortality rate was 5.3 % and the mean hospital stay was 4.1±5.2 days.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Aim: Electrical injuries are an important health problem in our country, as well as worldwide.
📊
Key Findings & Data:Methods: In this study, 38 patients who had been exposed to electrical injuries and treated at the Emergency Department of, Faculty of Medicine, Inonu University between October 2008 and October 2010 were reviewed.
💡
Conclusion & Impact:The overall mortality rate was 5.3 % and the mean hospital stay was 4.1±5.2 days.
🔬Design:Review & Systematic Survey
📍Scope:2008 Verileri
⚙️Variables:Domain Parameters

Abstract

Aim: Electrical injuries are an important health problem in our country, as well as worldwide. The aim of this study was to explore the demographic characteristics, complications and mortality associated with electrical injuries. Methods: In this study, 38 patients who had been exposed to electrical injuries and treated at the Emergency Department of, Faculty of Medicine, Inonu University between October 2008 and October 2010 were reviewed. Data pertaining to the patients were analysed retrospectively. Results: Out of 38 patients, 28 (73.7%) were male and 10 (26.3%) female. Electrical injuries were most frequently encountered in the 17-29 year age group, constituting 39.5% of cases. Eight (21.1%) patients were exposed to high voltage and 30 (78.9%) to low voltage. Among the circumstances leading to electrical injury, household accidents (63.2%) prevailed over the occupational accidents (36.8%). Two patients died due to sepsis. The overall mortality rate was 5.3 % and the mean hospital stay was 4.1±5.2 days. Conclusion: The results obtained from this research with respect to the demographic and clinical features can help the development of a particular strategy for electirical injuries. (The Medical Bulletin of Haseki 2010; 48: 139-41)

Özet

Amaç: Elektrik yaralanmaları tüm dünyada oldu¤u gibi ülkemizde de önemli bir sağlık sorunu olup, bu yaralanmalarla ilgili ülkemiz için yeterli veri bulunmamaktadır. Çalışmamızın amacı elektrik yaralanmalarının demografik özellikleri, komplikasyonları ve bu yaralanmalara bağlı gelişen mortalitenin araştırılmasıdır. Yöntemler: Bu çalışmada Ekim 2008-Ekim 2010 tarihleri arasında İnönü Üniversitesi Tıp Fakültesi Acil Tıp Anabilim dalına elektrik yaralanması ile getirilen ve tedavi edilen 38 hasta araştırıldı. Hastalarla ilgili bilgiler retrospektif olarak incelendi Bulgular: Olguların 28’i (%73,7) erkek, 10’u (%26,3) kadındı. Elektrik yaralanmalarının en sık 17-29 yaş aralı¤ında olduğu saptandı. Olguların 30’u (%78,9) düşük voltaj, 8’i (%21,1) ise yüksek voltajlı elektrik yaralanmasıydı. Elektrik yaralanmasına yol açan koşullar arasında ev kazaları (%63,2) iş kazalarından (36,8%) daha çok görülmekteydi. İki hastada ölüm nedeni sepsisti. Mortalite oranı %5,3, ortalama hastanede kalış süresi ise 4,1±5,2 gündü. Sonuç: Bu araştırmadan elde edilen bulgular demografik ve klinik özellikleri göz önüne alarak elektrik yaralanmasını önlemeye yönelik farklı bir strateji oluşturmasına hizmet edebilir. (Haseki Tıp Bülteni 2010; 48: 139-41)

🔖

Cite This Article

OĞUZTÜRK, H., TURTAY, M. G., ERTAN, C. (2010). Electrical injuries: The demographical and clinical features. Haseki Tıp Bülteni, Cilt: 48 - Sayı: 4, 139–141. https://ajindex.com/articles/268030

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (7)

  1. Chinnis AS, Williams JM, Treat KN. Electrical Injuries. In: Tintinalli JE, Kelen GD, Stapczynski JS. (Eds). Emergency Medicine. A Comprehensive Study Guide 5th ed. New York Mc Graw Hill 2000;1292-8
  2. Köse S, ‹yisoy A, Kursaklioglu H et al. Electrical injury as a possible cause of sick sinus syndrome. J Korean Med Sci 2003;18:114-5. [Abstract] / [PDF] 3. Dzhokic G, Jovchevska J, Dika A. Electrical Injuries: Etiology, Pathophysiology and Mechanism of Injury. Macedonian Journal of Medical Sciences 2008:15;1:54-8
  3. Martinez JA, Nyguyen T. Electrical injuries. Southern Medical Journal 2002:93;1165-9
  4. Yaşar MA, Yaşar D, Ödeş R ve ark. Yüksek voltaj elektrik çarpmasına ba¤lı akciğer ve karaciğer parankim yanı¤ı. Fırat Tıp Dergisi 2006;11:142-3.[Abstract] / [Full Text] / [PDF] 6. Koumbourlis AC. Electrical injuries. Crit Care Med 2002:30;425-30
  5. Cander B, Dur A, Koyuncu F ve ark. Elektrik yaralanmalarının demografik özellikleri ve yatış süresi üzerine etkili faktörler. Akademik Acil Tıp Dergisi 2010;2:72-4.[Abstract] / [PDF] 8. Durukan P, Yıldız M, Alagöz G ve ark. Elektrik yaralanmaları: üç yıllık analiz. Akademik Acil Tıp Dergisi 2006;5:27-9. [Abstract] / [PDF] 9. Türedi S, Gündüz A, Tatlı Ö ve ark. KTÜ Farabi hastanesi acil servisine elektrik yaralanmaları ile başvuran hastaların değerlendirilmesi. Akademik Acil Tıp Dergisi 2007;4:25-9. [Abstract] / [PDF] 10. Al B, Aldemir M, Guloglu C ve ark. Elektrik carpması sonucu acil servise başvuran hastaların epidemiyolojik özellikleri. Ulusal Travma Dergisi 2006;12:135-42. [Abstract] / [PDF] 11. Blackwell N, Hayllar J. A three year prospective audit of 212 presentations to the emergency department after electrical injury with a management protocol. Postgrad Med J 2002;78:283-5. [Abstract] / [Full Text] / [PDF] 12. Acıkel C, Eren F, Kale B, Celikoz B. Patient profile and primary treatment in high-voltage electrical injuries. Cerrahpaşa J Med 2002;33:104-9
  6. Günay K, Taviloğlu K, fiad O ve ark. Akut elektrik yanıkları: 6 yıllık deneyimlerimiz. Ulus Trav Derg 1995;1:97-101
  7. Cancio LC,Jimenez-Reyna JF, Barillo DJ, Walker SC, McManus AT, Vaughan GM. One hundred ninety- five cases of high-voltage electric injury. J Burn Care Rehabil 2005;26:331-40. [Abstract] 15. Sternnick I, Gomez RD, Serra MC ‘‘Train suffer’’ analysis of 23 cases of electrical burns caused by high tension railway overhead cables. Burns 2000;26:470-3. [Abstract] / [Full Text] / [PDF] 16. Masanes MJ, Gourbiere E, Prudent J et al. A high v