This case highlights the importance of implantable loop recorders in patients with unexplained syncope and that atrioventricular block is not the only mechanism of syncope in patients with aortic valve surgery. (The Medical Bulletin of Haseki 2012;50: 37-8)

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The authors present the case of a patient with aortic valve surgery and unexplained syncopal attacks.
📊
Key Findings & Data:With the use of an implantable loop recorder, sinus node dysfunction was diagnosed more than 4 months after implantation.
💡
Conclusion & Impact:This case highlights the importance of implantable loop recorders in patients with unexplained syncope and that atrioventricular block is not the only mechanism of syncope in patients with aortic valve surgery. (The Medical Bulletin of Haseki 2012;50: 37-8)
🔬Design:Research Article
📍Scope:2012 Verileri
⚙️Variables:Domain Parameters

Abstract

The authors present the case of a patient with aortic valve surgery and unexplained syncopal attacks. With the use of an implantable loop recorder, sinus node dysfunction was diagnosed more than 4 months after implantation. This case highlights the importance of implantable loop recorders in patients with unexplained syncope and that atrioventricular block is not the only mechanism of syncope in patients with aortic valve surgery. (The Medical Bulletin of Haseki 2012;50: 37-8)

Özet

Aort kapak operasyonu öyküsü bulunan hastalarda senkop etyolojisi daha çok atriyoventriküler düğümdeki ileti defektlerine bağlıdır. Aort darlığı nedeni ile protez kapak implantasyonu yapılan ve sonrasında senkop atakları olan hastanın tanısı implante edildikten 4 ay sonra takılabilir loop kaydedici yardımı ile sinüs düğümü disfonksiyonu olarak belirlenebilmiştir. Bu vaka aort kapak operasyon öyküsü bulunan bir hastada olağandışı senkop etyolojisini ve konvansiyonel testlerin yetersiz kaldığı durumlarda uzun dönemli kayıt imkânı sunan loop kaydedicilerin tanısal önemini göstermektedir. (Haseki Tıp Bül te ni 2012; 50: 37-8)

🔖

Cite This Article

AYDIN, A., GÜROL, T., YILMAZER, M. S., DAĞDEVİREN, B. (2012). Protez aort kapaklı bir hastada olağandışı senkop etiyolojisi. Haseki Tıp Bülteni, Cilt: 50 - Sayı: 1, 37–38. https://ajindex.com/articles/267976

References (11)

  1. Plack RH, Porterfield JK, Brinker JA. Complete heart block developing during aortic valvuloplasty. Chest 1989;6:1201-3
  2. Sukenik S, Pras A, Buskila D, Katz A, Snir Y, Horowitz J. Cardiovascular manifestations of ankylosing spondylitis. Clin Rheumatol 1987;6:588-92
  3. Russo G, Tamburino C, Bianca I, et al. Conduction disorders in aortic periprosthetic abscesses. Cardiologia 1989;34:629-33
  4. Von Oppell UO, Chimuka D, Brink JG, Zilla P. Aortic dissection repair with GRF glue complicated by heart block. Ann Thorac Surg 1995;59:761-3
  5. Lorenzoni R, Santoro GM, Calamai G, Masini G. Total atrioventricular block as the primary clinical manifestation of undiagnosed aortic dissection. G Ital Cardiol 1995;25:1031-5
  6. Fuduka T, Hawley RL, Edwards JE. Lesions of conduction tissue complicating aortic valvular replacement. Chest 1976;69:605-14
  7. Fournial JF, Brodaty D, Chomette G, Tereau Y, Cabrol C, Acar J. Conduction disorders after aortic valve replacement. A propos of 200 cases. Arch Mal Coeur Vaiss 1979;72:4-11
  8. Khally Z, Thibault B, Staniloae C, Theroux P, Dubuc M, Roy D, et al. Prognostic significance of newly acquired bundle branch block after aortic valve replacement. Am J Cardiol 2004; 94:1008-11
  9. Linzer M, Yang EH, Estes NA 3rd, Wang P, Vorperian VR, Kapoor WN. Diagnosing syncope. Part 2: Unexplained syncope. Clinical Efficacy Assessment Project of the American College of Physicians. Ann Intern Med 1997;127:76-86
  10. DiMarco JP. Value and limitations of electro- physiology testing for syncope. Cardiol Clin 1997;15:219-32
  11. Krahn AD, Klein GJ, AL, Skanes AC, Yee R. Insertable Loop Recorder Use for Detection of Intermittent Arrhythmias. Pacing Clin Electrophysiol 2004;27:657-64.