Journals / Haseki Tıp Bülteni / 2018 / Cilt: 56 - Sayı: 4

Intravesical Migration of Intrauterine Device: A Report of Cases of Total and Partial Migration

Mesaneye Rahim İçi Araç Migrasyonu: Total ve Parsiyel Migrasyonlu İki Olgunun Sunumu

Pages
329–332
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In the first case, IUD was petrified and completely migrated into the bladder wall; in the second case, IUD was hanged on to the bladder wall.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Intrauterine devices (IUD) are the commonly used long-acting, reversible and effective method of contraception.
📊
Key Findings & Data:Migration of IUD into the bladder via uterine perforation is a very rare complication.
💡
Conclusion & Impact:In the first case, IUD was petrified and completely migrated into the bladder wall; in the second case, IUD was hanged on to the bladder wall.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Intrauterine devices (IUD) are the commonly used long-acting, reversible and effective method of contraception. Migration of IUD into the bladder via uterine perforation is a very rare complication. In this paper, we aimed to present two different cases with different migration steps. In the first case, IUD was petrified and completely migrated into the bladder wall; in the second case, IUD was hanged on to the bladder wall.

Özet

Rahim içi araç (RİA); uzun süreli, etkili ve tekrar kullanım için uygun, yaygın bir doğum kontrol yöntemidir. Uterusun perforasyonu ve RİA’nın mesane içerisinde yer değiştirmesi nadir olarak rastlanılan bir komplikasyondur. Çalışmamızda, mesaneye RİA migrasyonunun farklı aşamalarını saptadığımız iki olguyu sunmayı amaçladık. Olguların ilkinde RİA tamamen mesaneye migre olmuş ve tamamen taşlaşmış olarak saptandı. Diğerinde ise RİA mesane duvarında asılı idi ve sadece uçları taşlaşmıştı

🔖

Cite This Article

ŞAHİN, M. O., ŞEN, V., DOĞAN, B. (2018). Intravesical Migration of Intrauterine Device: A Report of Cases of Total and Partial Migration. Haseki Tıp Bülteni, Cilt: 56 - Sayı: 4, 329–332. https://ajindex.com/articles/267810

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Dede FS, Dilbaz B, Sahin D, Dilbaz S. Vesical calculus formation around a migrated copper-T 380-A. Eur J Contracept Reprod Health Care 2006;11:50-52.
  2. Dietrick DD, Issa MM, Kabalin JN, Basssett JB. Intravesical migration of intrauterin device. J Urol 1992;147:1327-44.
  3. Harrison-Woolrych M, Ashton J, Coulter D. Uterineperforation on intrauterine device insertion: is the incidence higher thanpreviously reported? Contraception 2003;67:53-6.
  4. Nouira Y, Rakrouki S, Gargouri M, Fitouri Z, Horchani A. Intravesical migration of an intrauterine contraceptive device complicated by bladder stone: a report of six cases. Int Urogynecol J Pelvic Floor Dysfunct 2007;18:575-8.
  5. Üçer O, Şahin MO, Gümüş B. İngüinal herni onarımı sonrası mesaneye spanç migrasyonu. Türk Üroloji Dergisi 2008;34:264-5.
  6. Mannan A, Anwar S, Qayyum A, Tasneem RA. Foreign bodies in the urinary bladder and their management: A Pakistani experience. Singapore Med J 2011;52:24-28.
  7. Bansal A, Yadav P, Kumar M, Sankhwar S, Purkait B, Jhanwar A, Singh S. Foreign bodies in the bladder and their management: a single-centre experience from North India. Int Neurourol J 2016;20:260-9.
  8. Priyadarshi V, Sehgal N, Sen D. Ureteric erosion and obstruction: A rare dreaded complication of intrauterine contraceptive device. Urol Ann 2017;9:103-6.
  9. Weerasekera A, Wijesinghe P, Nugaduwa N. Sigmoid colocolic fistula caused by intrauterine device migration: A cese report. J Med Case Rep 2014;8:81. Kassab B, Audra P. The migrating intrauterine device.Case report and review of the 165 cases. Concept fertil Sex 1999;27:696-700.
  10. Sun CC, Chang CC, Yu MH. Far-migrated intra-abdominal intrauterine device with abdominal pain. Taiwan J Obstet Gynecol 2008;47:244-6.
  11. Rafique M, Rauf A, Khan NA, Haque TU: An unusual cause of vesical stone: A migrant intrauterine device. Eur J Contracept Reprod Health Care 2003;8:170-2.
  12. Ozçelik B, Serin IS, Basbug M, Aygen E, Ekmekçioglu O. Differential diagnosis of intra-uterine device migrating to bladder using radiographic imageof calculus formation and review of literature. Eur J Obstet Gynecol Reprod Biol 2003;108:94-6.
  13. Guvel S, Tekin MI, Kilinç F, Peskircioglu L, Ozkardes H. Bladder stone around a migrated and missed intrauterine contraceptive device. Int J Urol 2001;8:78-9.
  14. Eskandar OS, Eckford SD. Intravesical migration of a GyneFIx intrauterine device. J Fam Plann Reprod Health Care 2003;29:237-8. Zakin D. Perforation of the Bladder by the Intrauterine Device. Obstetrical Gynecolo Surv 1984;39:59-66.