Journals / International Journal of Applied Mathematics Electronics and Computers / 2016 / Special Issue (2016)

Detection and Counting of Embryonic Stem Cells in Fluorescence Microscopy Images by a Fully Automatic Method

Pages
277–281
Publication Date
2016-12-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The method is tested on a database contains two image groups at different noise levels validated by the specialists.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this paper, an automatic cell counting method under microscopy is proposed.
📊
Key Findings & Data:Overlap and incorrect adjusted microscopy parameters are the main factors that cause inaccurate counting results.
💡
Conclusion & Impact:The method is tested on a database contains two image groups at different noise levels validated by the specialists.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:cell counting · cell detection · pre-processing

Abstract

In this paper, an automatic cell counting method under microscopy is proposed. The cell counting process can be performed in two ways: The manual counting in which a specialist counts the cells with naked eye, and the automatic counting that utilizes the computer-based techniques. In manual counting, there are several techniques for dying the cells to turn them visible with naked eye. However, if the concentration is more than normal the cells can overlap. Overlap and incorrect adjusted microscopy parameters are the main factors that cause inaccurate counting results. Furthermore, in manual counting inter-observer variability is high. Even though the same cell image is taken into account by the different specialist, different counting results can be obtained. Because of the above mentioned problems, the cell counting process must be performed automatically. The proposed automatic stem cell counting process is based on image processing techniques that appropriate the frame of method. At first, stem cell sections were obtained under the fluorescence microscopy. In the following pre-processing step Gaussian filtering and background extraction are performed. Before applying watershed algorithm histogram of the image is partitioned in to four parts and the best combination is determined to obtain the most exact counting results. The aim of using watershed algorithm is to make the boundaries and maximum points of the cells more clear. Finally, spherical contours corresponding to the stem cells are counted. The effectiveness of the proposed method is evaluated by performing numerous computer simulations. It is shown that the proposed method gives promising results and can eliminate the subjectivity originated from the manual counting. The method is tested on a database contains two image groups at different noise levels validated by the specialists.

🔖

Cite This Article

ÇETİNEL, G., KAMANLI, A. F. (2016). Detection and Counting of Embryonic Stem Cells in Fluorescence Microscopy Images by a Fully Automatic Method. International Journal of Applied Mathematics Electronics and Computers, Special Issue (2016), 277–281. https://ajindex.com/articles/258198

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (17)

  1. Seçil Erden, Stem cells and clinical applications, Journal of New Results in Engineering and Natural Science, No: 3, pp.1-8, 2014
  2. Geisa Martins Faustino et. al., Automatic embryonic stem cells detection and counting in fluorescence microscopy images, Monografias em Ciência da Computação, No. 04/09 ISSN: 0103-9741, 2009
  3. J.M. Geusebroek et al., Segmentation of cell clusters by nearest neighbor graphs, Proceedings of the third annual conference of the Advanced School for Computing and Imaging, pp. 248–252, 1997
  4. V. Meas-Yedid et al. Quantitative microscopic image analysis by active contours, in Vision Interface Annual Conference 2001 – Medical Applications, 2001
  5. J. Kittler and J. Illingworth, “Minimum error thresholding,” Pattern Recognition, vol. 19, no. 1, pp. 41–47, 1986
  6. N. Otsu, A threshold selection method from gray-level histograms, IEEE Transactions on Systems, Man, and Cybernetics, vol. 9, no. 1, pp. 62–66, 1979
  7. K. Wu, D. Gauthier, and M. Levine, Live cell image segmentation, IEEE Transactions on Biomedical Engineering, vol. 42, no. 1, pp. 1–12, 1995
  8. T. Markiewicz et al. Myelogenous leukemia cell image preprocessing for feature generation, in 5th International Workshop on Computational Methods in Electrical Engineering, pp. 70–73, 2003
  9. K. Althoff, J. Degerman, and T Gustavsson. Combined segmentation and tracking of neural stemcells. In Image Analysis, 2005
  10. C. Tang and E. Bengtsson. Segmentation and tracking of neural stem cell. In Advances in Intelligent Computing, pages 851–859. 2005
  11. N. N. Kachouie, P. Fieguth, and E. Jervis. Stem-cell localization: A deconvolution problem. In EMBS, 5525 – 5528, 2007
  12. N. N. Kachouie, Paul Fieguth, John Ramunas, and Eric Jervis. Probabilisticmodel-based cell tracking. Int. Journal of Biomedical Imaging, pages 1 – 10, 2006
  13. N. N. Kachouie, L. J. Lee, and P. Fieguth. A probabilistic living cell segmentation model. In ICIP, pages 137 – 140, 2005
  14. C. Gonzalez & R. E. Woods. Gonzalez. Digital Image Processing, 3rd ed.2008
  15. Yingmao Li, Asif Iqbal and Nicholas R. Gans, Multiple lane boundary detection using a combination of low-level image features, IEEE 17th International Conference on Intelligent Transportation Systems (ITSC) October 8-11, 2014
  16. Mark A. Foltz. Connected components in binary images. 6.866: Machine Vision, December 1997
  17. Çetinel G., Kamanlı A. F, Automatic Embryonic Stem Cell Counting Method Isıtes international Conference 2