Journals / Iğdır Üniversitesi Fen Bilimleri Enstitüsü Dergisi / 2021 / Cilt: 11 - Sayı: 1

Volumetric Efficiency Evaluation of the Use of Refrigerants R445a, R515a, R456a, ND, and R516a with Low GWP Instead of R134a

Pages
500–511
Publication Date
2021-03-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

When the refrigerants considered are evaluated together, it was determined that R445a provides the best values according to R134a and has an average cooling capacity of approximately 12% is higher.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, the performance of different refrigerants (with low GWP value) depending on thermophysical properties in the cooling system was evaluated.
📊
Key Findings & Data:The cooling capacities of R134a, R445a, R515a, R456a, ND, and R516a refrigerants used in the cooling system are determined per unit refrigerant.
💡
Conclusion & Impact:When the refrigerants considered are evaluated together, it was determined that R445a provides the best values according to R134a and has an average cooling capacity of approximately 12% is higher.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Coolant fluid · Volumetric efficiency · R515a

Abstract

In this study, the performance of different refrigerants (with low GWP value) depending on thermophysical properties in the cooling system was evaluated. The cooling capacities of R134a, R445a, R515a, R456a, ND, and R516a refrigerants used in the cooling system are determined per unit refrigerant. If the compressor speed values and the volumetric efficiency of the compressor are constant, the results of the effects of the refrigerants in the cooling system are compared with each other. When the system is operated with R445a, the highest COP value is obtained when the volumetric efficiency value is 0.7. The R515a provided the closest COP value to R134a when the compressor speed was 1750 rpm and the 98% coefficient of performance value was similar. When the refrigerants considered are evaluated together, it was determined that R445a provides the best values according to R134a and has an average cooling capacity of approximately 12% is higher.

🔖

Cite This Article

İŞKAN, Ü., DİREK, M., KOYUNOĞLU, C., YÜKSEL, F. (2021). Volumetric Efficiency Evaluation of the Use of Refrigerants R445a, R515a, R456a, ND, and R516a with Low GWP Instead of R134a. Iğdır Üniversitesi Fen Bilimleri Enstitüsü Dergisi, Cilt: 11 - Sayı: 1, 500–511. https://ajindex.com/articles/256352

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Abas N, Kalair AR, Khan N, Haider A, Saleem Z, Saleem MS, 2018. Natural and synthetic refrigerants, global warming: a review, Renewable Sustain Energy Reviews 90: 557–569.
  2. Aral MC, Suhermanto M, Hosoz M, 2020. Performance evaluation of an automotive air conditioning and heat pump system using R1234yf and R134a, Science and Technology for the Built Environment DOI: 10.1080/23744731.2020.1776067. Azzolin M, Berto A, Bortolin S, Moro L, Del Col D, 2019. Condensation of ternary low GWP zeotropic mixtures inside channels, International Journal of Refrigeration 103: 77–90.
  3. Bayrakçı HA, Özgür E, 2009. Energy and exergy analysis of vapor compression refrigeration system using pure hydrocarbon refrigerants, International Journal of Energy Research International Journal Energy Research 33: 1070–1075.
  4. Cheng Z, Wang B, Shi W, Li X, 2017. Numerical research on R32/R1234ze(E) air source heat pump under variable mass concentration, International Journal of Refrigeration, 82: 1–10.
  5. Devecioğlu A. G, Oruç V, 2017. An analysis on the comparison of low-GWP refrigerants to alternatively use in mobile air-conditioning systems, Thermal Science and Engineering Progress, 1: 1–5.
  6. Direk M, Mert MS, Yüksel F, Keleşoğlu A, 2018. Exergetic investigation of a R1234yf automotive air conditioning system with internal heat exchanger, International Journal of Thermodynamics 21,2: 103-109
  7. Direk M, Soylu E, 2018. The effect of internal heat exchanger using R1234ze(E) as an alternative refrigerant in a mobile air-conditioning system, Strojniški vestnik - Journal of Mechanical Engineering, 64: 114-120.
  8. Direk M, Kelesoglu A, Akin A, 2017. Drop-in performance analysis and effect of IHX for an automotive air conditioning system with R1234yf as a replacement of R134a. Strojniški vestnik-Journal of Mechanical Engineering, 63: 5, 314-319. European Parliament and the Council, 2014. No 517/2014 of the European Parliament and of the Council of 16 April 2014 on fluorinated greenhouse gases and repealing regulation (EC). No 842/2006 text with EEA relevance. Off. J. Eur. Union L 150/195-230.
  9. Gaurav G, Kumar R, 2018. Computational energy and exergy analysis of R134a. R1234yf. R1234ze and their mixtures in vapour compression system, Ain Shams Engineering Journal, 9: 3229–3237.
  10. Heredia-Aricapa Y, Belman-Flores JM, Mota-Babiloni A, Serrano-Arellano J, García-Pabón JJ, 2020. Overview of low GWP mixtures for the replacement of HFC refrigerants: R134a. R404A and R410A, International Journal of Refrigeration, 111: