Journals / Turkish Journal of Chemistry / 2005 / Cilt: 29 - Sayı: 5

Development of Gold Porous Plate Electrode and Examination of Its Performance for Iodine Determination

Pages
507–512
Publication Date
2005-05-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Under the optimal conditions, the voltammetric results show that the gold porous plate electrode offers the detection limit of 2.18 x 10-5 M and reproducibility of 7.8% (n = 4).

📌 3 Key Takeaways

🎯
Objective & Hypothesis:A novel procedure for the construction of a home-made gold porous plate electrode is described.
📊
Key Findings & Data:The performance of the electrode developed was tested using iodine solution as analyte material.
💡
Conclusion & Impact:Under the optimal conditions, the voltammetric results show that the gold porous plate electrode offers the detection limit of 2.18 x 10-5 M and reproducibility of 7.8% (n = 4).
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Gold porous plate electrode · determination of iodine · voltammetry

Abstract

A novel procedure for the construction of a home-made gold porous plate electrode is described. A plate of silver and gold alloy was treated with nitric acid or alternatively by anodic oxidation to remove the silver component, leaving a porous surface having active sites for adsorption. The performance of the electrode developed was tested using iodine solution as analyte material. The parameters related to the working conditions were optimized before the examination of analytical characteristics. Under the optimal conditions, the voltammetric results show that the gold porous plate electrode offers the detection limit of 2.18 x 10-5 M and reproducibility of 7.8% (n = 4). The electrode performance was compared with that of glassy carbon electrode (G.C.E), gold-wire and platinized Pt electrodes in terms of current density for 2 x 10-4 M iodine solution. In conclusion, it is observed that the gold porous plate electrode has better current density than gold wire and platinized Pt electrodes.

Özet

A novel procedure for the construction of a home-made gold porous plate electrode is described. A plate of silver and gold alloy was treated with nitric acid or alternatively by anodic oxidation to remove the silver component, leaving a porous surface having active sites for adsorption. The performance of the electrode developed was tested using iodine solution as analyte material. The parameters related to the working conditions were optimized before the examination of analytical characteristics. Under the optimal conditions, the voltammetric results show that the gold porous plate electrode offers the detection limit of 2.18 x 10-5 M and reproducibility of 7.8% (n = 4). The electrode performance was compared with that of glassy carbon electrode (G.C.E), gold-wire and platinized Pt electrodes in terms of current density for 2 x 10-4 M iodine solution. In conclusion, it is observed that the gold porous plate electrode has better current density than gold wire and platinized Pt electrodes.

🔖

Cite This Article

KIRGÖZ, Ü. A., TURAL, H. (2005). Development of Gold Porous Plate Electrode and Examination of Its Performance for Iodine Determination. Turkish Journal of Chemistry, Cilt: 29 - Sayı: 5, 507–512. https://ajindex.com/articles/253792