Journals / Bilecik Şeyh Edebali Üniversitesi Fen Bilimleri Dergisi / 2019 / Cilt: 6 - Sayı: 2

The Effect of Magnetized Water on Compressive and Flexural Strength of Reactive Powder Concretes

Manyetize Edilmiş Suyun, Reaktif Pudra Betonların Eğilme ve Basınç Dayanımı Üzerindeki Etkisi

Pages
21–29
Publication Date
2019-09-30
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

When the results are assessed, it can be concluded that using of magnetic water instead of normal water causes increase in 7 and 28 days compressive and flexural strength.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The aim of this study is to investigate the effect of magnetized water on compressive and flexural strength of reactive powder concrete (RPC).
📊
Key Findings & Data:In this study, the effects of three different magnetic field intensities i.e. 0.8-1 and 1.2 Tesla have been assessed on compressive and flexural strength of RPC.
💡
Conclusion & Impact:When the results are assessed, it can be concluded that using of magnetic water instead of normal water causes increase in 7 and 28 days compressive and flexural strength.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Magnetized Water · Compressive Strength · Flexural Strength

Abstract

The aim of this study is to investigate the effect of magnetized water on compressive and flexural strength of reactive powder concrete (RPC). Different magnetic field intensities can be used for magnetic water production. In this study, the effects of three different magnetic field intensities i.e. 0.8-1 and 1.2 Tesla have been assessed on compressive and flexural strength of RPC. The magnetic water used for manufacturing of the specimens was exposed to magnetic fields for 20 minutes in all mixes. When the results are assessed, it can be concluded that using of magnetic water instead of normal water causes increase in 7 and 28 days compressive and flexural strength. In addition, it has been determined that the most efficient magnetic field strength is 1 Tesla to increase the strength.

Özet

Bu çalışmanın amacı; manyetize edilmiş suyun, lifli ve lifsiz reaktif pudra betonların (RPB) basınç ve eğilme dayanımı üzerindeki etkisini incelemektir. Farklı manyetik alan şiddetleri manyetik su üretimi için kullanılabilmektedir. Bu çalışmada; 0.8-1 ve 1.2 Tesla şiddetindeki üç farklı manyetik alan şiddeti seçilmiştir. Manyetik su üretimi için farklı manyetik alan şiddetlerinde bekletme süresi 20 dakika olarak sabit alınmıştır. Elde edilen sonuçlar incelendiğinde; normal su kullanımı yerine manyetik su kullanımı, 7 ve 28 günlük basınç ve eğilme dayanımlarının artmasını sağladığı görülmüştür. Ayrıca manyetize edilmiş suyun, RPB’lerin basınç ve eğilme dayanımına olumlu etkisi olduğu ve dayanımı artırmak için en verimli manyetik alan şiddetinin 1 Tesla olduğu tespit edilmiştir.

🔖

Cite This Article

MOHABBI, M., VAROLGÜNEŞ, S. (2019). The Effect of Magnetized Water on Compressive and Flexural Strength of Reactive Powder Concretes. Bilecik Şeyh Edebali Üniversitesi Fen Bilimleri Dergisi, Cilt: 6 - Sayı: 2, 21–29. https://ajindex.com/articles/251509

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. Afshin, H., Gholizadeh, M., & Khorshidi, N. (2010). Improving mechanical properties of high strength concrete by magnetic water technology. Scientia Iranica, 17
  2. Bache, H. H. (1981). Densified cement/ultra-fine particle-based materials: Aalborg Portland Aalborg, Denmark
  3. Bonneau, O., Lachemi, M., Dallaire, E., Dugat, J., & Aitcin, P.-C. (1997). Mechanical properties and durability of two industrial reactive powder concretes. Materials Journal, 94(4), 286-290
  4. Cheyrezy, M., Maret, V., & Frouin, L. (1995). Microstructural analysis of RPC (reactive powder concrete). Cement and Concrete Research, 25(7), 1491-1500
  5. Choi, M. S., Kim, Y. S., Kim, J. H., Kim, J.-S., & Kwon, S. H. (2014). Effects of an externally imposed electromagnetic field on the formation of a lubrication layer in concrete pumping. Construction and Building Materials, 61, 18-23
  6. Feylessoufi, A., Crespin, M., Dion, P., Bergaya, F., Van Damme, H., & Richard, P. (1997). Controlled rate thermal treatment of reactive powder concretes. Advanced cement based materials, 6(1), 21-27
  7. Fu, W., & Wang, Z. (1994). The new technology of concrete engineering. Beijing: The Publishing House of Chinese Architectural Industry, 56-59
  8. Karabulut, A. Ş. (2006). Reaktif Pudra Betonunun Özelliklerinin Mineral Katkılarla Geliştirilmesi. (Yüksek Lisans Tezi), Dokuz Eylül Üniversitesi Fen Bilimleri Enstitüsü, İzmir
  9. Mohabbi, M., & Varolgüneş, S. (2019). Farklı Kür Koşullarının Reaktif Pudra Betonların Mekanik Özelliklerine Etkisi. Dicle Üniversitesi Mühendislik Fakültesi Dergisi (DUMF), baskı aşamasında
  10. Rahgozar, M. A., & Zamani, M. (2015). Performance and Properties of Concrete with Magnetic Water
  11. Reddy, B. S. K., Ghorpade, V. G., & Rao, H. S. (2013). Effect of magnetic field exposure time on workability and compressive strength of magnetic water concrete. Int J Adv Engg Tech/IV/III/July-Sept, 120, 122
  12. Reddy, V. S., Kumar, A. K., & Sumanth, A. (2017). Effect of Magnetic Field Treated Water on Fresh and Hardened Properties of Concrete. environments, 3, 4
  13. Richard, P., & Cheyrezy, M. (1995). Composition of reactive powder concretes. Cement and Concrete Research, 25(7), 1501-1511
  14. Roux, N., Andrade, C., & Sanjuan, M. (1996). Experimental study of durability of reactive powder concretes. Journal of Materials in Civil Engineering, 8(1), 1-6
  15. Roy, D. M., Gouda, G., & Bobrowsky, A. (1972). Very high strength cement pastes prepared by hot pressing and other hi