Journals / Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi / 2019 / Cilt: 12 - Sayı: 3

Wear Behaviour of HA-TiO2 Coatings Fabricated by Plasma Spray

Plazma Püskürtme Kaplama Yöntemiyle Üretilmiş HA ve TiO2 Kaplamaların Aşınma Davranışlarının İncelenmesi

Pages
1392–1401
Publication Date
2019-12-31
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In the case of single-layer TiO2 coating, the least material loss occurred as a result of the wear tests.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Hydroxyapatite (HA) bioceramic coatings are widely used in medical implants in order to improve biocompatibility and corrosion resistance.
📊
Key Findings & Data:In this study, Single layer HA, TiO2 and double layer HA/TiO2 coatings were fabricated by plasma spray.
💡
Conclusion & Impact:In the case of single-layer TiO2 coating, the least material loss occurred as a result of the wear tests.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Hidroksiapatit · Plazma püskürtme · Aşınma

Abstract

Hydroxyapatite (HA) bioceramic coatings are widely used in medical implants in order to improve biocompatibility and corrosion resistance. But, HA coatings suffers from poor mechanical properties in agressive environment. In this study, Single layer HA, TiO2 and double layer HA/TiO2 coatings were fabricated by plasma spray. Wear behavior of coatings in dry and SBF environment was investigated. As a result, the single layer HA coating had the weakest wear resistance. However, abrasion resistance improved as a result of the double layer coating design with TiO2. In the case of single-layer TiO2 coating, the least material loss occurred as a result of the wear tests.

Özet

Hidroksiapatit (HA) biyoseramik kaplamalar medikal implant uygulamalarında biyouyumluluğu ve korozyon direncini arttırmak amacıyla yaygın olarak kullanılmaktadır. Fakat HA kaplamalar zayıf mekanik özellikleri sebebiyle saldırgan ortamlarda kolayca hasar alabilmektedir. Bu çalışmada tek katman HA, TiO2 ve çift katman HA/TiO2 kaplamalar plazma püskürtme yöntemi ile üretilmiştir. Kaplamaların kuru ortamda ve SBF ortamında aşınma davranışları incelenmiştir. Elde edilen sonuçlar neticesinde tek katman HA kaplamanın en zayıf aşınma direncine sahip olduğu belirlenmiştir. Fakat TiO2 ile çift katman kaplama dizaynı sonucunda aşınma dayanımında iyileşmeler meydana gelmiştir. Tek katman TiO2 kaplamada ise aşınma deneyleri sonucunda en az malzeme kaybı meydana geldiği anlaşılmıştır.

🔖

Cite This Article

KARABAŞ, M., KAYALI, Y. (2019). Wear Behaviour of HA-TiO2 Coatings Fabricated by Plasma Spray. Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi, Cilt: 12 - Sayı: 3, 1392–1401. https://ajindex.com/articles/234159

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (7)

  1. Baptista, R., Gadelha, D., Bandeira, M., Arteiro, D., Delgado, M. I., Ferro, A. C., & Guedes, M. (2016). Characterization of titanium-hydroxyapatite biocomposites processed by dip coating. Bulletin of Materials Science, 39(1), 263-272. doi:10.1007/s12034-015-1122-6
  2. Cannillo, V., Lusvarghi, L., & Sola, A. (2008). Production and characterization of plasma-sprayed TiO2-hydroxyapatite functionally graded coatings. Journal of the European Ceramic Society, 28(11), 2161-2169. doi:10.1016/j.jeurceramsoc.2008.02.026 Chen, C. C., Huang, T. H., Kao, C. T., & Ding, S. J. (2006). Characterization of functionally graded hydroxyapatite/titanium composite coatings plasma‐sprayed on Ti alloys. Journal of Biomedical Materials Research Part B: Applied Biomaterials: An Official Journal of The Society for Biomaterials, The Japanese Society for Biomaterials, and The Australian Society for Biomaterials and the Korean Society for Biomaterials, 78(1), 146-152.
  3. Farnoush, H., & Rezaei, Z. (2017). Effect of suspension stability on bonding strength and electrochemical behavior of electrophoretically deposited HA–YSZ nanostructured composite coatings. Ceramics International, 43(15), 11885-11897. doi:https://doi.org/10.1016/j.ceramint.2017.06.036
  4. Fathi, M. H., & Doostmohammadi, A. (2009). Bioactive glass nanopowder and bioglass coating for biocompatibility improvement of metallic implant. Journal of Materials Processing Technology, 209(3), 1385-1391. doi:10.1016/j.jmatprotec.2008.03.051 Heimann, R. B. (2016). Plasma-Sprayed Hydroxylapatite-Based Coatings: Chemical, Mechanical, Microstructural, and Biomedical Properties. Journal of Thermal Spray Technology, 25(5), 827-850. doi:10.1007/s11666-016-0421-9
  5. Karimi, S., Mahzoon, F., Javadpour, S., & Janghorban, K. (2015). Study of wear and corrosion behavior of cathodic plasma electrolytic deposition of zirconia-hydroxyapatite on titanium and 316L stainless steel in Ringer's solution. International Journal of Materials Research, 106(6), 614-620. doi:10.3139/146.111229 Khor, K. A., Li, H., & Cheang, P. (2003). Processing-microstructure-property relations in HVOF sprayed calcium phosphate based bioceramic coatings. Biomaterials, 24(13), 2233-2243. doi:10.1016/S0142-9612(03)00027-9
  6. Khun, N. W., Li, Z., Khor, K. A., & Cizek, J. (2016). Higher in-flight particle velocities enhance in vitro tribological behavior of plasma sprayed hydroxyapatite coatings. Tribology International, 103, 496-503. doi:https://doi.org/10.1016/j.triboint.2016.08.006
  7. Kim, S