Journals / Anestezi Dergisi / 2006 / Cilt: 14 - Sayı: 3

Pacemakers, implantable cardioverter defibrillators and surgery

Kalp pilleri, implante edilebilir kardiyoverter defibrilatörler ve cerrahi

Pages
164–170
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Since these devices can be affected by some surgical equipment, awareness of such interference is crucial to prevent complications.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Pacemakers (PM) and implantable cardioverter defibrillators (ICD) are high technology devices used for the treatment of bradyarrhythmias and/or tachyarrhythmias.
📊
Key Findings & Data:As the average life expectancy increases, pacemaker I ICD therapy has become increasingly popular, resulting in more patients with PM I ICD requiring noncardiac surgery.
💡
Conclusion & Impact:Since these devices can be affected by some surgical equipment, awareness of such interference is crucial to prevent complications.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Defibrilatör · takılabilir · Kalp pili

Abstract

Pacemakers (PM) and implantable cardioverter defibrillators (ICD) are high technology devices used for the treatment of bradyarrhythmias and/or tachyarrhythmias. These devices deliver electrical impulses to the heart through an electrode. Patients with PM I ICD's are generally elderly patients with serious cardiovascular diseases. As the average life expectancy increases, pacemaker I ICD therapy has become increasingly popular, resulting in more patients with PM I ICD requiring noncardiac surgery. Since these devices can be affected by some surgical equipment, awareness of such interference is crucial to prevent complications.

Özet

Kalp pilleri (PM) ve implante edilebilir kardiyoverter defibrilatörler (ICD) bradiaritmi ve taşiaritmi tedavisinde kullanılan ve batarya kaynaklı elektrik enerji uyarılarını elektrodlar aracılığıyla kalbe gönderen, gelişmiş cihazlardır. PM I ICD'si olan hasta­lar genellikle ileri yaştadır ve ciddi kardiyovasküler hastalıkları vardır. Toplumun ortalama yaşam süresi arttıkça daha fazla hasta PM I ICD gerektirmektedir. Sonuç olarak PM I ICD'li daha çok hasta kardiyak olmayan cerrahiye alınmaktadır. Bu cihazlar, cer­rahi işlemler sırasında kullanılan bazı ekipmanlardan etkilenebilmektedir. Bu etkileşimlerin bilinmesi ve gerektiğinde cihazlara müdahale edilmesi olası birçok komplikasyonu önleyecektir.

🔖

Cite This Article

ÖZİN, B., YİĞİT, F. (2006). Pacemakers, implantable cardioverter defibrillators and surgery. Anestezi Dergisi, Cilt: 14 - Sayı: 3, 164–170. https://ajindex.com/articles/216679

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Thevent A, Hodges MD, Lillehei CW. The use of a myocardial electrode inserted percutaneously for control of complete atri-oventricular block by an artificial pacemaker. Dis Chest 1958
  2. Payzın S. Kardiyak pacemaker. İstanbul, Mas Matbaacılık
  3. Yeşil M, Ankan ME. Kalıcı kalp pillerinde uyarı biçimleri, (ed.) Oto A, Aytemir K, Çeliker A, Köse S, Özin B, Kalıcı Kalp Pilleri ve împlante Edilebilir Defibrilatörler. Ankara, Erkem Tıbbi Ya­yıncılık, 2005
  4. Nişancı Y. Kalıcı kalp pili uygulama indikasyonları. (ed.) Oto A, Aytemir K, Çeliker A, Köse S, Özin B, Kalıcı Kalp Pilleri ve İmp-lante Edilebilir Defibrilatörler. Ankara, Erkem Tıbbi Yayıncılık, 2005
  5. Myerburg RJ, Castellanos A. Cardiac arrest and sudden cardiac death. In: Braunwald E, Zipes DP, Libby P, (eds.) Heart Disease: A Textbook of Cardiovascular Medicine, Philadelphia, WB Saun-ders 2001:890-931. 6.Spooner PM, Albert C, Benjamin EJ, ve ark. Sudden cardiac de­ath, genes and arrhythmogenesis: consideration of new population and mechanistic approaches from a National Heart, Lung and Blood Institute workshop, part I. Circulation 2001
  6. Mirowski M, Reid PR, Mower M, ve ark. Termination of malig­nant ventricular arrhythmias with an implantable automatic defib-rillator in human beings. N Eng J Med 1980
  7. Mercanoğlu F. İmplante edilebilir kardiyoverter defibrilatörler. İmplantasyon teknikleri ve programlama, (ed.) Oto A, Aytemir K, Çeliker A, Köse S, Özin B, Kalıcı Kalp Pilleri ve İmplante Edilebi­lir Defibrilatörler. Ankara, Erkem Tıbbi Yayıncılık, 2005
  8. O'Neill MJ Jr, Davis D. Pacemakers in noncardiac surgery. Surg Clin North Am 1983 Oct
  9. Nercessian OA, Wu H, Nazarian D, Mahmud F. Intraoperative pa­cemaker dysfunction caused by the use of electrocautery during atotal hip arthroplasty. J Arthroplasty 1998
  10. Purday JP, Towey RM. Apparent pacemaker failure caused by activation of ventricular threshold test by a magnetic instrument padduring general anesthesia. Br j Anesth 1992
  11. Santomauro M, Ferraro S, Maddalena G, ve ark. Pacemaker mal­function due to subcutaneous emphysema: a case report. Angiology. 1992
  12. Tandoğan İ. Kalp pilleri üzerine çevresel etkiler, (ed.) Oto A,Aytemir K, Çeliker A, Köse S, Özin B, Kalıcı Kalp Pilleri ve İmp­lante Edilebilir Defibrilatörler. Ankara, Erkem Tıbbi Yayıncılık,2005
  13. Eagle Ka, Berger PB, Calkins H, et al. ACC/AHA Guideline Up­date for Perioperativ