Automated measurement of intima-media thickness of carotid arteries in ultrasonography by computer software

Pages
105–108
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The use of dedicated software may be proposed to reduce the measurement errors.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:PURPOSE Intima-media thickness (IMT) has been proposed to be a morphological criterion of atherosclerosis.
📊
Key Findings & Data:MATERIALS AND METHODS High-resolution common carotid artery (CCA) images of 88 patients that have been obtained by a linear broadband L5-12 MHz transducer and archived in PACS were retrospectively evaluated.
💡
Conclusion & Impact:The use of dedicated software may be proposed to reduce the measurement errors.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Gözlemci farklılığı · Arteriyoskleroz · Görüntü işleme

Abstract

PURPOSE Intima-media thickness (IMT) has been proposed to be a morphological criterion of atherosclerosis. The purpose of this study was to investigate the interobserver variability of manual and also of computer software measurements of IMT. MATERIALS AND METHODS High-resolution common carotid artery (CCA) images of 88 patients that have been obtained by a linear broadband L5-12 MHz transducer and archived in PACS were retrospectively evaluated. Two separate investigators, who were unaware of the former results, evaluated the same images by using computer software that had a dedicated tool for automatic measurement of IMT. The results of the investigators were compared. RESULTS According to the two investigators who have performed manual measurements, mean values of IMT of right CCA were 0.6396 mm and 0.6356 mm; of the left CCA were 0.6662 mm and 0.6575 mm, respectively. The interobserver variability of measurements revealed the mean IMT as 0.6071 mm and 0.6048 mm for the right, 0.6216 mm and 0.6227 mm for the left CCA. Manual measurements of both investigators were found to be higher than the automatic measurements and the differences were statistically significant. Interobserver correlation of manual measurements was between 0.80-0.88 and of the automated measurements was between 0.93-0.98. CONCLUSION Manual measurements reveal higher values than the automated measurements of IMT. The interobserver correlation of automated measurements is higher than manual measurements. The use of dedicated software may be proposed to reduce the measurement errors.

🔖

Cite This Article

SEÇİL, M., ALTAY, C., GÜLCÜ, A., ÇEÇE, H., GÖKTAY, A. Y., DİCLE, O. (2005). Automated measurement of intima-media thickness of carotid arteries in ultrasonography by computer software. Diagnostic and Interventional Radiology, Cilt: 11 - Sayı: 2, 105–108. https://ajindex.com/articles/216104

References (13)

  1. Blankenhorn DH, Selzer RH, Crawford DW, et al. Beneficial effects of colestipolniacin therapy on the common carotid artery: two- and four-year reduction of intima-media thickness measured by ultrasound.Circulation 1993; 88:20-28
  2. Crouse JR III, Byington RP, Bond MG, et al. Pravastatin, lipids, and atherosclerosis in the carotid arteries (PLAC-II). Am J Cardiol 1995; 75:455-459
  3. Furberg CD, Adams HP, Applegate WB, et al., ACAPS Research Group. Effect of lovastatin on early carotid atherosclerosis and cardiovascular events.Circulation 1994; 90:1679-1687
  4. Lees RS. Non-invasive detection of vascular function and dysfunction. Curr Opin Lipidol 1993; 4:325-329
  5. Salonen JT, Salonen R. Ultrasound B-mode imaging in observational studies of atherosclerotic progression. Circulation 1993; 87(Suppl. II):56-65
  6. Wikstrand J, Wendelhag I. Quantitative ultrasonography of carotid and femoral arteries. In: Lanzer P, Rösch J, eds. Vascular Diagnostics. Berlin, Germany: Springer-Verlag 1994; 129-138
  7. Wendelhag I, Liang Q, Gustavsson T, Wikstrand J. A new automated computerized analyzing system simplifies readings and reduces the variability in ultrasound measurement of intima-media thickness. Stroke 1997; 28:2195-2200
  8. Wendelhag I, Gustavsson T, Suurküla M, Berglund G, Wikstrand J. Ultrasound measurement of wall thickness in the carotid artery: fundamental principles and description of a computerized analysing system. Clin Physiol 1991; 11:565-577
  9. Wendelhag I, Wiklund O, Wikstrand J. On quantifying plaque size and intima-media thickness in carotid and femoral arteries: comments on results from a prospective ultrasound study in patients with familial hypercholesterolemia. Arterioscler Thromb Vasc Biol 1996; 16:843-850
  10. Sidhu PS, Desai SR. A simple and reproducible method for assessing intimal-medial thickness of the common carotid artery. Br J Radiol 1997;70:85-89
  11. Baldassarre D, Tremoli E, Amato M, Veglia F, Bondioli A, Sirtori CR. Reproducibility validation study comparing analog and digital imaging technologies for the measurement of intima-media thickness. Stroke 2000; 31:1104-1110
  12. Belcaro G, Geroulakos G, Laurora G, Cesarone MR, De Sanctis MT, Incandela L, Barsotti A. Inter/intra-observer variability of carotid and femoral bifurcation intima-media thickness measurements. Panminerva Med 1993; 35:75-79
  13. Salonen R, Haapanen A, Salonen JT. Measurement of intima-media thickness of common carotid arteries with high-resolution B-mode u