Journals / Erciyes Medical Journal / 2019 / Cilt: 41 - Sayı: 1

Does the Diameter of the Prosthesis Affect the Outcome of Stapedotomy?

Pages
37–40
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

However, only at 2000 Hz, AC thresholds were found to be better in patients with a 0.6 mm prosthesis than in those with a 0.4 mm prosthesis.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: To compare the outcomes of the stapedotomies performed using Teflon prostheses with 0.4 mm and 0.6 mm diameters.
📊
Key Findings & Data:Materials and Methods: Pre- and postoperative audiograms of 52 participants, who had undergone stapedotomy, were evaluated retrospectively.
💡
Conclusion & Impact:However, only at 2000 Hz, AC thresholds were found to be better in patients with a 0.6 mm prosthesis than in those with a 0.4 mm prosthesis.
🔬Design:Research Article
📍Scope:2000 Verileri
⚙️Variables:Domain Parameters

Özet

Objective: To compare the outcomes of the stapedotomies performed using Teflon prostheses with 0.4 mm and 0.6 mm diameters. Materials and Methods: Pre- and postoperative audiograms of 52 participants, who had undergone stapedotomy, were evaluated retrospectively. Participants were divided into two groups according to the diameter of the prosthesis used for their surgery: Group 1 (0.4 mm) and Group 2 (0.6 mm). Air conduction (AC) pure tone thresholds at 250, 500, 1000, 2000, 4000, and 6000 Hz and air–bone gaps (ABGs) at 500, 1000, 2000, and 4000 Hz, as well as pure tone averages (PTAs), were compared within and between groups. Results: Hearing gain, with regard to AC thresholds and ABGs, was statistically significant within both groups for each frequency (p 0.05). Whereas the preoperative AC thresholds were similar between the groups at all frequencies, postoperative AC thresholds of the 0.6 mm group were better than those of the 0.4 mm group at 2000 Hz (p 0.05). Conclusion: The outcomes of the stapedotomies with 0.4 and 0.6 mm Teflon prostheses were similar to each other with regard to postoperative hearing gain, PTA, and ABG. However, only at 2000 Hz, AC thresholds were found to be better in patients with a 0.6 mm prosthesis than in those with a 0.4 mm prosthesis.

🔖

Cite This Article

ŞAHİN, M. İ., AVCI, D., ŞAN, F., KETENCİ, İ., ÜNLÜ, Y. (2019). Does the Diameter of the Prosthesis Affect the Outcome of Stapedotomy?. Erciyes Medical Journal, Cilt: 41 - Sayı: 1, 37–40. https://ajindex.com/articles/215328

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (4)

  1. Menger D, Tange R. The aetiology of otosclerosis: a review of the literature. Clin Otolaryngol Allied Sci 2003; 28(2): 112–20. [CrossRef] Shahnaz N, Bork K, Polka L, Longridge N, Bell D, Westerberg BD. Energy reflectance and tympanometry in normal and otosclerotic ears. Ear Hear 2009; 30(2): 219–33. [CrossRef] Hüttenbrink KB. Biomechanics of stapesplasty: a review. Otol Neurotol 2003; 24(4): 548–59. [CrossRef] Dancer A, Franke R. Biomechanics of the middle ear. [Article in French]. Rev Laryngol Otol Rhinol 1995; 116(1): 5–12.
  2. Colletti V, Fiorino FG, Sittoni V, Policante Z. Mechanics of the middle ear in otosclerosis and stapedoplasty. Acta Otolaryngol 1993; 113(3): 637–41. [CrossRef] Sennaroglu L, Ünal ÖF, Sennaroglu G, Gürsel B, Belgin E. Effect of Teflon piston diameter on hearing result after stapedotomy. Otolaryngol Head and Neck Surg 2001; 124(3): 279–81. [CrossRef] Vincent R, Sperling NM, Oates J, Jindal M. Surgical findings and longterm hearing results in 3,050 stapedotomies for primary otosclerosis: a prospective study with the otology-neurotology database. Otol Neurotol 2006; 27(8): S25–47. [CrossRef] Wegner I, Eldaebes MM, Landry TG, Grolman W, Bance ML. The effect of piston diameter in stapedotomy for otosclerosis: a temporal bone model. Otol Neurotol 2016; 37(10): 1497–502. [CrossRef] Bernardeschi D, De Seta D, Canu G, Russo FY, Ferrary E, Lahlou G, et al. Does the diameter of the stapes prosthesis really matter? A prospective clinical study. Laryngoscope 2018; 128(8): 1922–6.
  3. Faranesh N, Magamseh E, Zaaroura S, Zeidan R, Shupak A. Hearing and Otoacoustic Emissions Outcome of Stapedotomy: Does the Prosthesis Diameter Matter? J Int Adv Otol 2017; 13(2): 162–70. [CrossRef] Fisch U. Stapedotomy versus stapedectomy. Otol Neurotol 2009;30(8):1166–7. [CrossRef] Shabana Y, Ghonim M, Pedersen C. Stapedotomy: does prosthesis diameter affect outcome? Clin Otolaryngol Allied Sci 1999; 24(2): 91–4.
  4. Wegner I, Verhagen JJ, Stegeman I, Vincent R, Grolman W. A systematic review of the effect of piston diameter in stapes surgery for otosclerosis on hearing results. Laryngoscope 2016; 126(1): 182– 90. [CrossRef] Dhooge I, Desmedt S, Maly T, Loose D, Van Hoecke H. Long-term hearing results of stapedotomy: analysis of factors affecting outcome. Eur Arch Otorhinolaryngol 2018; 275(5): 1111–9. [CrossRef] Ardiç F, Aykal K, Tümkaya F, Kara C, Barlay F. Improvement of hearing results by bone cement fixation in endoscopic stapedotomy. J Laryngol Otol 2018: 132(6): 486–8