Journals / Diagnostic and Interventional Radiology / 2005 / Cilt: 11 - Sayı: 2

Correlation between the adverse reactions to intravenous iodinated contrast media and IgE levels

Pages
74–76
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Electrochemiluminescense immunoassay method ought to be scrutinized for the detection of IgE binded with iodinated contrast media.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:PURPOSE The adverse reactions of the iodinated contrast media are believed to be non-IgE mediated and the result of triggering of the release of the mast cell mediators directly.
📊
Key Findings & Data:MATERIALS AND METHODS Blood samples were taken from 110 patients who underwent excretory urography just before the administration of the iodinated contrast media and on the 40th minute.
💡
Conclusion & Impact:Electrochemiluminescense immunoassay method ought to be scrutinized for the detection of IgE binded with iodinated contrast media.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Ürografi · Kontrast ortamı · İmmünoglobulin E

Abstract

PURPOSE The adverse reactions of the iodinated contrast media are believed to be non-IgE mediated and the result of triggering of the release of the mast cell mediators directly. However, the exact mechanism is still controversial and purpose of this prospective study is not only to determine any possible correlation of adverse reactions with total baseline blood IgE levels, but also to investigate the change of the IgE levels in the blood after the administration of the IV iodinated contrast media and correlate this with the various side effects. MATERIALS AND METHODS Blood samples were taken from 110 patients who underwent excretory urography just before the administration of the iodinated contrast media and on the 40th minute. Further blood samples were collected from 13 randomly selected patients out of the total 110, a week after the examinations. Total IgE levels were calculated in all samples using electrochemiluminescense immunoassay method. RESULTS IgE levels decreased statistically significantly using paired t test in all patients but one. The side effects were independent from the total baseline IgE levels according to the chi-square testing. CONCLUSION Results reveal that the measurement of the total baseline IgE levels can not be a prognostic factor for the adverse reactions to iodinated contrast media but the more a factor causes immuneglobuline to decrease after administration of iodinated contrast media, the less adverse reactions happen. Electrochemiluminescense immunoassay method ought to be scrutinized for the detection of IgE binded with iodinated contrast media.

🔖

Cite This Article

GÜRSES, C., GÜLER, A. (2005). Correlation between the adverse reactions to intravenous iodinated contrast media and IgE levels. Diagnostic and Interventional Radiology, Cilt: 11 - Sayı: 2, 74–76. https://ajindex.com/articles/215322

References (11)

  1. Luskin AT, Luskin SS. Anaphylaxis and anaphylactoid reactions: diagnosis and management. Am J Therap 1996; 3:515-520
  2. Bush WH, Swanson DP. Acute reactions to intravascular contrast media: types, risk factors, recognition, and specific treatment.AJR Am J Roentgenol 1991; 157:1153-1161
  3. Beers MH, Berkow R. The Merck Manual, Merck & Co., 1999 17th Edition, 1053
  4. Lasser EC. The multipotential pseudoantIgEnicity of X-ray cantrast media: pseudoantigenexcess may downregulate the release of hypotensive mediators. Int Arch Allergy Immunol 2000; 123:282-290
  5. Mita H, Tadokoro K, Akiyama K. Detection of IgE antibody to a radiocontrast medium. Allergy 1998; 53:1133-1140
  6. Morcos SK, Thomsen HS. Adverse reactions to iodinated contrast media. Eur Radiol 2001; 11:1267-1275
  7. Laroche D, Aimone-Gastin I, Dubois F, et al. Mechanism of severe, immediate reactions to iodinated contrast material. Radiology 1998; 209:183-190
  8. Laroche D, Namour F, Lefrançois C, et al. Anaphylactoid and anaphylactic reactions to iodinated contrast material. Allergy 1999; 54:13-16
  9. Rodriguez RM, Gueant JL, Aimone-Gastin I, Gerard P, Amoghly F, et al. The increased histamine release in ischemic heart disease patients undergoing coronary angiography is not mediated by specific IgE. Allergy 2002; 57:61-66
  10. Miyauchi T, Hirano T, Ushiyama C, Ovary Z, Okumura K, Katayama H. Anaphylactic IgE and IgG1 production for hapten can be enhanced by contrast media. Br J Radiol 1996; 69:920-924
  11. Dati F, Ringel KP. Reference values for serum IgE in healthy and non-atopic children and adults. Clin Chem 1982; 28:1556.