Journals / Turkish Journal of Medical Sciences / 2014 / Cilt: 44 - Sayı: 6

Evaluation of scleral-fixated intraocular lens position anomalies by anterior segment optical coherence tomography

Pages
1118–1123
Publication Date
2014-06-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The present study showed that a tilted scleral-fixated IOL behaved like a toric IOL, and the astigmatism caused by the position of the scleral-fixated IOL therefore could increase or decrease total astigmatism.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:To measure the positions of scleral-fixated intraocular lenses (IOLs) using anterior segment optical coherence tomography (OCT) and to evaluate the influence of the position of scleral-fixated IOL on the quality of vision.
📊
Key Findings & Data:Materials and methods: Twenty-six eyes of 26 patients were included in the study.
💡
Conclusion & Impact:The present study showed that a tilted scleral-fixated IOL behaved like a toric IOL, and the astigmatism caused by the position of the scleral-fixated IOL therefore could increase or decrease total astigmatism.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Cataract · intraocular lens position · optical coherence tomography

Abstract

To measure the positions of scleral-fixated intraocular lenses (IOLs) using anterior segment optical coherence tomography (OCT) and to evaluate the influence of the position of scleral-fixated IOL on the quality of vision. Materials and methods: Twenty-six eyes of 26 patients were included in the study. The average age was 57.5 (11 to 78) years. Anterior segment images were taken using slit lamp optical coherence tomography (SL-OCT) and were used to evaluate the position of the IOL. Results: The average amounts of tilt and decentration were 2.25° ± 1.93° and 359.28 ± 194.70 µm, respectively. There was a positive and moderate relationship between tilt and astigmatism caused by the position of the IOL (P = 0.030). No relationship was detected between decentration and the astigmatism caused by the position of the IOL (P = 0.285). Conclusion: Scleral-fixated IOL position can be evaluated with SL-OCT, which is a noncontact, noninvasive, reproducible, and reliable method of evaluation. Anterior segment OCT has been shown to provide sensitive measurements but not in all cases. The present study showed that a tilted scleral-fixated IOL behaved like a toric IOL, and the astigmatism caused by the position of the scleral-fixated IOL therefore could increase or decrease total astigmatism.

Özet

To measure the positions of scleral-fixated intraocular lenses (IOLs) using anterior segment optical coherence tomography (OCT) and to evaluate the influence of the position of scleral-fixated IOL on the quality of vision. Materials and methods: Twenty-six eyes of 26 patients were included in the study. The average age was 57.5 (11 to 78) years. Anterior segment images were taken using slit lamp optical coherence tomography (SL-OCT) and were used to evaluate the position of the IOL. Results: The average amounts of tilt and decentration were 2.25° ± 1.93° and 359.28 ± 194.70 µm, respectively. There was a positive and moderate relationship between tilt and astigmatism caused by the position of the IOL (P = 0.030). No relationship was detected between decentration and the astigmatism caused by the position of the IOL (P = 0.285). Conclusion: Scleral-fixated IOL position can be evaluated with SL-OCT, which is a noncontact, noninvasive, reproducible, and reliable method of evaluation. Anterior segment OCT has been shown to provide sensitive measurements but not in all cases. The present study showed that a tilted scleral-fixated IOL behaved like a toric IOL, and the astigmatism caused by the position of the scleral-fixated IOL therefore could increase or decrease total astigmatism.

🔖

Cite This Article

POLAT, N., DEVRANOĞLU, K. K., ÖZDAMAR, M. A., ARICI, C. (2014). Evaluation of scleral-fixated intraocular lens position anomalies by anterior segment optical coherence tomography. Turkish Journal of Medical Sciences, Cilt: 44 - Sayı: 6, 1118–1123. https://ajindex.com/articles/215215

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Baykara M, Ertürk H, Avcı R, Karataş A, Akova B. Skleral fiksasyon yöntemi ile göz içi lens implantasyonu. Turk J Ophthalmol 2004; 34: 55–60 (article in Turkish with summary in English). Trimarchi F, Stringa M, Vellani G, Iato MS. Scleral fixation of an intraocular lens in the absence of capsular support. J Cataract Refract Surg 1997; 23: 795–797.
  2. Bashshur Z, Ma’luf R, Najjar D, Noureddin B. Scleral fixation of posterior chamber intraocular lenses using fascia lata to cover the knots. Ophthalmic Surg Lasers 2002; 33: 445–449.
  3. Kozaki J, Tanihara H, Yasuda A, Nagata M. Tilt and decentration of the implanted posterior chamber intraocular lens. J Cataract Refract Surg 1991; 17: 592–595.
  4. Boyd BF, Agarwal A. Wavefront analysis and corneal topography. In: Boyd BF, Agarwal A, Alio JL, Krueger RR, Wilson SE, editors. Wavefront Analysis, Aberrometers and Corneal Topography. Panama; Highlights of Ophthalmology; 2003. pp. 217–242. Özdamar A. Aberometreler ve topografi aracılı laser sistemleri. In: The 24th Turkish National Ophthalmology Training, Refractive Surgery; 2004. pp. 65–68.
  5. Obstbaum SA, To K. Posterior chamber intraocular lens dislocations and malpositions. Aust N Z J Ophthalmol 1989; 17: 265–271.
  6. Lyle WA, Jin JC. An analysis of intraocular lens exchange. Ophthalmic Surg 1992; 23: 453–458.
  7. Auffarth GU, Wilcox M, Sims JC, McCabe C, Wesendahl TA, Apple DJ. Analysis of 100 explanted one‐piece and three‐piece silicone intraocular lenses. Ophthalmology 1995; 102: 1144– 1150. Carlson AN, Stewart WC, Tso PC. Intraocular lens complications requiring removal or exchange. Surv Ophthalmol 1998; 42: 417–440.
  8. Mamalis N, Davis B, Nilson CD, Hickman MS, Leboyer RM. Complications of foldable intraocular lenses requiring explantation or secondary intervention – 2003 survey update. J Cataract Refract Surg 2004; 30: 2209–2218.
  9. Chakrabarti A, Gandhi RK, Chakrabarti M. Ab externo 4-point scleral fixation of posterior chamber intraocular lenses. J Cataract Refract Surg 1999; 25: 420–426.
  10. Duffey RJ, Holland EJ, Agapitos PJ, Lindstrom RL. Anatomic study of transsclerally sutured intraocular lens implantation. Am J Ophthalmol 1989; 108: 300–309.
  11. Steinert RF, Huang D. Anterior Segment Optical Coherence Tomography. Thorofare, NJ, USA: SLACK Inc.; 2008.
  12. Kozaki J, Takahashi F. Theoretical analysis of image defocus with intraocular lens decentration. J Cataract Refract Surg 1995; 21: 552–555.
  13. Steiner A, Steinhorst UH, Steiner M, Theischen M, Winter R. [Ultrasound biomicroscopy for localiz